• Title/Summary/Keyword: Peak Detector

Search Result 323, Processing Time 0.026 seconds

Fabrication of Virtual Frisch-Grid CdZnTe ${\gamma}$-Ray Detector (가상 Frisch-그리드를 이용한 CdZnTe 감마선 소자 제작)

  • Park, Chansun;Kim, Pilsu;Cho, PyongKon;Choi, Jonghak;Kim, Jungmin;Kim, KiHyun
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.253-259
    • /
    • 2014
  • Large volume of $6{\times}6{\times}12mm^3$ CdZnTe ${\gamma}$-ray detector was fabricated with CdZnTe single crystals grown by Traveling Heater Method (THM) to evaluate the energy resolution of 662 keV in $^{137}Cs$. Hole tailing effect which originated from the large mobility difference in electron and hole degrade energy resolution of radiation detector and its effects become more severe for a large volume detectors. Generally, single carrier collection technique is very useful method to remove/minimize hole tailing effect and thereby improvement in energy resolution. Virtual Frisch-grid technique is also one of single charge collection method through weighting potential engineering and it is very simple and easily applicable one. In this paper, we characterized CZT detector grown by THM and evaluated the effectiveness of virtual Frisch-grid technique for a high energy gamma-ray detector. The proper position and width of virtual Frisch-grid was determined from electric field simulation using ANSYS Maxwell ver. 14.0. Energy resolution of 2.2% was achieved for the 662 keV ${\gamma}$-peak of $^{137}Cs$ with virtual Frisch-grid CdZnTe detector.

A Burst-mode Automatic Power Control Circuit Robust io Mark Density Variations (마크 밀도 변화에 강한 버스트 모드 자동 전력 제어 회로)

  • 기현철
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.4
    • /
    • pp.67-74
    • /
    • 2004
  • As data rate was increased, the conventional burst-mode automatic power control circuit caused errors due to the effort of the mark density variation. To solve this problem we invented a new structured peak-comparator which could eliminate the effect of the mark density variation even in high date rate, and revised the conventional one using it. We proposed a burst-mode automatic power control circuit robust to mark density variations. We found that the peak-comparator in the proposed automatic power control circuit was very robust to mark density variations because it affected very little by the mark density variation in high date rate and in the wide variation range of the reference current and the difference current.

Design of High Speed Analog Input Card for Ultrasonic Testing (초음파 탐상을 위한 고속 아날로그 입력 카드의 설계)

  • 이병수;이동원;박두석
    • Journal of the Korea Society of Computer and Information
    • /
    • v.5 no.4
    • /
    • pp.62-68
    • /
    • 2000
  • It was designed a high-speed analog input card that is a important device of ultrasonic testing flaw detector in the middle of non-destructive testing in this Paper. The A/D Board is inquired high-speed sampling rate and fast data acquisition system. This pater shows a design that has a function of Peak- Detection for ultrasonic testing by ISA Bus type and a 50MHz of A/D converter in order to do sampling more than quadruple frequency of transducer frequency.

  • PDF

Cyclic Shift Based Tone Reservation PAPR Reduction Scheme with Embedding Side Information for FBMC-OQAM Systems

  • Shi, Yongpeng;Xia, Yujie;Gao, Ya;Cui, Jianhua
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.8
    • /
    • pp.2879-2899
    • /
    • 2021
  • The tone reservation (TR) scheme is an attractive method to reduce peak-to-average power ratio (PAPR) in the filter bank multicarrier with offset quadrature amplitude modulation (FBMC-OQAM) systems. However, the high PAPR of FBMC signal will severely degrades system performance. To address this issue, a cyclic shift based TR (CS-TR) scheme with embedding side information (SI) is proposed to reduce the PAPR of FBMC signals. At the transmitter, four candidate signals are first generated based on cyclic shift of the output of inverse discrete Fourier transform (IDFT), and the SI of the selected signal with minimum peak power among the four candidate signals is embedded in sparse symbols with quadrature phase-shift keying constellation. Then, the TR weighted by optimal scaling factor is employed to further reduce PAPR of the selected signal. At the receiver, a reliable SI detector is presented by determining the phase rotation of SI embedding symbols, and the transmitted data blocks can be correctly demodulated according to the detected SI. Simulation results show that the proposed scheme significantly outperforms the existing TR schemes in both PAPR reduction and bit error rate (BER) performances. In addition, the proposed scheme with detected SI can achieve the same BER performance compared to the one with perfect SI.

Comparison of Various Methods for Estrus Stage Determination in Bitch (개의 발정 진단 방법에 따른 효율 비교)

  • Ko, Young-Jin;Kang, Eun-Ju;Lee, Sung-Lim
    • Journal of Embryo Transfer
    • /
    • v.24 no.3
    • /
    • pp.131-137
    • /
    • 2009
  • In dogs, correct diagnosis of estrus is important and the exact time of ovulation can be determined by variouse methods. Vaginal cytology has commonly used in conjunction with the physical examination, clinical history, vaginoscopy, and hormonal assays to determine the stage of the reproductive cycle. This study was therefore investigated the effectiveness of direct ovulation detector designed by changes of electrical resistance in vaginal mucus following different estrus cycles with several methods; vaginal cytology, concentration of plasma estrogen and progesterone, and direct examination by laparotomy. A total of 12 bitches was selected for the study and observed estrus signs. The bitches were evaluated clinical sign (vulvar swelling and bleeding), cytological examination (keratocyte and RBC), electrical resistance, plasma estrogen and progesterone concentration for estrus assessment. Accuracy of ovulation detection by vaginal cytology was significantly (p<0.05) lower than those by electrical resistance and plasma progesterone concentration, based on the confirmation by laparotomy. Vaginal smear is not confidential method compared to detection of electrical resistance and plasma progesterone concentration at ovulation. Although the value of electrical resistance was varied at the same points of estrus in individuals, ovulation was occurred at the first day which shown the peak of electrical resistance and mating time was third day after peak. In conclusion, ovulation detector designed by changes of electrical resistance is an effective and economic instrument for predicting estrus and ovulation in bitches.

Corrections of Self-Absorption Effect Using the Monte Carlo Method in the Radioactivity Analysis of Environmental Samples (환경시료의 방사능 분석에서 Monte Carlo 방법을 이용한 자체흡수 효과 보정)

  • Seo, Bum-Kyoung;Lee, Dae-Won;Lee, Kil-Yong;Yoon, Yoon-Yeol;Yang, Tae-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.51-58
    • /
    • 2001
  • In the low level radioactivity measurement, such as environmental radioactivity, there were used commonly cylindrical and Marinelli type beakers by means of measurement container. If there are differences in the matrix density or sample height between standard source and sample, it must be determined full energy peak efficiency considering self absorption effect. In this paper, we compared measured efficiency with calculated full energy peak efficiencies in the HPGe detector using the Monte Carlo method. For cylindrical container, we calculated the variation of the efficiency with sample height. Also, we calculated the variation of the detection efficiency with apparent density in the cylindrical and Marinelli container. It was seen that it need to be corrected for self absorption in the energy range of below 1000keV. Also, in order to verify the validity of calculation, we compared the calculated value with reference value using NIST SRM 4353 reference soil.

  • PDF

Development of One-channel Gamma ray spectroscope for Automatic Radiopharmaceutical Synthesis System (방사성 의약품 자동합성장치용 단채널 감마선 분광기 보드의 설계 및 제작)

  • Song, Kwanhoon;Kim, Kwangsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.193-200
    • /
    • 2014
  • In this paper, the prototype of one-channel gamma-ray spectroscope for automatic radiopharmaceutical systhesis system was designed and characterized. The prototype employed CZT (CdZnTe) spear detector for gamma-ray detection and employed analog-type signal processing method. A radioactive sample Co-60 was used for measuring performance of the gamma-ray spectroscope and energy spectrum is gained with bandwidth of 1173keV. The analog board is made up of SF (shaping filter) and PHA (peak and hold amplifier) for shaping CZT output signal appropriately and ADC (analog to digital converter) and FPGA (field programmable gate array) for drawing gamma-ray spectrum by counting the digitalized gamma-ray signal data.

Proposal and Implementation of 2-D OCDMA System with Reconfigurable Array Encoder/Decoder and Double Hard Limiters (배열형 가변 부호기/복호기와 이중 하드 리미터를 적용한 2-D OCDMA시스템 제안 및 구현)

  • 김진석;김범주;권순영;박종대
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7A
    • /
    • pp.705-711
    • /
    • 2004
  • We propose novel OCDMA system with the structure of reconfigurable may encoder/decoder(RAE/ RAD), which are able to reallocate the 2-D optical codes to each subscriber and recover the transmitted data at all the receiving nodes. We have first implemented the double hard limiters composed of limiting amplifier(first hard limiter) that maintain a level of the encoded data from receiving node and AND detector(second hard limiter) for detecting the position of the encoded data and recovering the data. With the proposed system, it was successfully implemented to recover a specific channel data out of 16 code-multiplxed channels using FPGA and 4 DFB-LDs having distinct wavelengths. From experimental results, the code length resulted from increasing the number of the simultaneously connected channels has been reduced by using 2-D OCDMA multiplexed in time and wavelength instead of 1-D OCDMA. In addition, bit errors phenomenon on account of deterioration of autocorrelation peak-to-side lobe ratio is enhanced by using the double hard limiters composed of AND detector and limiting amplifiers.

Studies on Long-wavelength Infrared Detector using Multiple Stacked InAs Quantum Dot Layers (다층 InAs 양자점을 이용한 장파장 적외선 수광소자에 관한 연구)

  • Kim, Jong-Wook;Oh, Jae-Eung;Hong, Seong-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.8
    • /
    • pp.42-47
    • /
    • 2000
  • Long-wavelength infrared (LWIR) detectors made of self-assembled quantum dots embedded in the channel region of high electron mobility transistor (HEMT) is demonstrated. Above 180 K, the detector shows low dark currents due to strong confinement effect of electrons in InAs quantum dots and exhibits the broad spectral response ranging from 7 mm to 11 mm. The peak detectivity ($D^*$) of $1.93{\times}10^{10}cmHz^{1/2}/W$ is obtained at 9.4 mm. The photocurrent characteristics as a function of applied bias are similar to that of normal FETs, while the photocurrent decreases as the applied electric field exceeds $2{\times}10^3V/cm$ because of the increased dark current.

  • PDF

A Study on the Measurement of Spectral Characteristics of Semiconductor Light Sources driven by Very Short Pulse Currents (짧은 펄스로 구동되는 반도체 발광소자의 파장측정에 관한 연구)

  • 김경식;김재창;조호성;홍창희
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.198-203
    • /
    • 1990
  • In this paper, a system has been proposed for the measurement of the spectral characteristic of semiconductor light sources driven by very short pulse currents. This system has been constituted a monochrometer of 600 groovedmm grating and of 275 mm focal length, X-Y recorder, scanning motor which enables the system to get the analog data, and amplifier coupled with peak detector. Especially, peak detector was used to convert the short pulse signal to continuous one. In order to verify the resolution with slit width, several slits were made by the hands. By using this system, the spectra of commercial LEDs, AlGaAdGaAs LD, and InGaAsPIInP BH-LD which were driven with pulse current (duty cy$e = 0.01) were measured. From these measurements, it has been shown that the proposed system has about 1 A1$\AA$ resolution and 10$\mu$W sensitivity.

  • PDF