• Title/Summary/Keyword: Pattern repair

Search Result 164, Processing Time 0.028 seconds

Laser Microfabrications for Next-Generation Flat Panel Display (레이저를 이용한 차세대 평판 디스플레이 공정)

  • Kim, Kwang-Ryul
    • Korean Journal of Materials Research
    • /
    • v.17 no.7
    • /
    • pp.352-357
    • /
    • 2007
  • Since a pattern defects "repair" system using a diode pumped solid state laser for Flat Panel Display (FPD) was suggested, a lot of laser systems have been explored and developed for mass-production microfabrication process. A maskless lithography system using 405 nm violet laser and Digital Micromirror Device (DMD) has been developed for PDP and Liquid Crystal Display (LCD) Thin Film Transistor (TFT) photolithography process. In addition, a "Laser Direct Patterning" system for Indium Tin Oxide (ITO) for Plasma Display Panel(PDP) has been evaluated one of the best successful examples for laser application system which is applied for mass-production lines. The "heat" and "solvent" free laser microfabrications process will be widely used because the next-generation flat panel displays, Flexible Display and Organic Light Emitting Diode (OLED) should use plastic substrates and organic materials which are very difficult to process using traditional fabrication methods.

Mechanical and Environment Ability of FRP Pole for a Distribution Line (배전용 FRP전주의 기계적 및 환경성능)

  • 박기호;조한구;한동희;이웅선;송일근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.395-398
    • /
    • 2000
  • In this study mechanical and environment ability of FRP pole for a distribution line about high strength and good insulation properties. The basic filament winding process creates a helical winding pattern. In mechanical analysis of splice with mechanical fastened joint it is important to evaluate a critical load of faster having maximum stress. It is also present a result of several examples to compare this with analytical one. On repair design this finite element method will be used as basis. The influence of environmental factors, such as elevated temperatures, high humidity, and corrosive fluids, and ultraviolet(UV) rays, upon the performance of polymeric matrix composite is of concern in many applications.

  • PDF

NLRP3 Inflammasome as Therapeutic Targets in Inflammatory Diseases

  • Annamneedi Venkata Prakash;Il-Ho Park;Jun Woo Park;Jae Pil Bae;Geum Seon Lee;Tae Jin Kang
    • Biomolecules & Therapeutics
    • /
    • v.31 no.4
    • /
    • pp.395-401
    • /
    • 2023
  • Innate immunity is a first line defence system in the body which is for sensing signals of danger such as pathogenic microbes or host-derived signals of cellular stress. Pattern recognition receptors (PRR's), which present in the cell memebrane, are suspect the infection through pathogen-associated molecular patterns (PAMP), and activate innate immunity with response to promote inflammation via inflammatory cells such as macrophages and neutrophils, and cytokines. Inflammasome are protein complexes which are part of innate immunity in inflammation to remove pathogens and repair damaged tissues. What is the important role of inflammation in disease? In this review, we are focused on the action mechanism of NLRP3 inflammasome in inflammatory diseases such as asthma, atopic dermatitis, and sepsis.

Animal Model for the Evaluation of Repair of Injured Inferior Alveolar Nerve with Nerve Growth Factor

  • Lee, Jae-Yoon;Park, Suhyun;Heo, Hyun-A;Pyo, Sung-Woon
    • Journal of Korean Dental Science
    • /
    • v.6 no.2
    • /
    • pp.58-66
    • /
    • 2013
  • Purpose: The inferior alveolar nerve (IAN) can be damaged as a result of minor oral surgical procedure such as third molar extraction or implant placement. Repair of the injured IAN involves difficulty of access, and research studies are limited to elucidating the process of regeneration by surgical methods. This study sought to establish the rabbit animal model to apply polymeric membrane functionalized with nerve growth factor after a crush lesion for the evaluation of nerve regeneration using the electrophysiologic method. Materials and Methods: The IAN of 2 adult male New Zealand white rabbits (4 nerves) were exposed bilaterally, and crush injury rendered by jeweler's forceps was applied. Nerve conduction velocity was examined electrophysiologically using electromyography before, after, and 4 weeks after the crush injury. To evaluate the regeneration, the pattern of action potential of IAN was recorded, and the characteristics of neurons were histologically observed. Result: After the crush injury, afferent activity decreased in the injured group. Electromyography could not be recorded after four weeks because tissues surrounding the injured nerve collapsed. Decrease in the mean number of axons was observed in the injured part with membrane. Conclusion: Despite the limited result, the present animal model study may provide a possible way to research on the methods of enhancing the recovery of nerve injuries in clinical situations. For clinically widespread acceptance, however, it should gain more consecutive and scientific evidences.

Minimal Medial-row Tie with Suture-bridge Technique for Medium to Large Rotator Cuff Tears

  • Lee, Hyun Il;Ryu, Ho Young;Shim, Sang-Jun;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.4
    • /
    • pp.197-205
    • /
    • 2015
  • Background: The purpose of this study was to evaluate the postoperative magnetic resonance imaging (MRI) results of minimal-tying (one medial-row tie among 4 medial-row sutures) on the medial-row in double-row suture-bridge configuration ($2{\times}2$ anchor with $4{\times}4$ suture stands). Methods: From 2011 March to 2012 July, 79 patients underwent arthroscopic rotator cuff repair using $2{\times}2$ anchor double-row configuration. The mean age was 61.3 years (range, 31-81 years). Two double-loaded suture anchors were used for medial-row. Four medial-row stitches were made with only one medial-row knot-tying (the most anterior suture). Lateral-row was secured using the conventional suture-bridge anchor technique; all 4 strands were used for each anchor. Repair integrity was evaluated with MRI at mean 6.2 months postoperatively. Retear and the pattern of retear, change of fatty infiltration, and muscle atrophy of supraspinatus were evaluated using pre- and postoperative MRI. Results: Repaired tendon integrity was 38 for type I, 30 for type II, 6 for type III, 4 for type IV, and 1 for type V, according to Sugaya classification. Considering type IV/V as retear, the rate was 6.3% (5 out of 79 patients). Medial cuff failure was observed in 4 patients. Fatty atrophy of supraspinatus was significantly improved postoperatively according to Goutallier grading (p=0.01). The level of muscle atrophy of supraspinatus was not changed significantly after surgery. Conclusions: Minimal tying technique with suture configuration of four-by-four strand double-row suture-bridge yielded a lower retear rate (6.3%) in medium to large rotator cuff tears.

Theoretical Investigations on Structure and Function of Human Homologue hABH4 of E.coli ALKB4

  • Shankaracharya, Shankaracharya;Das, Saibal;Prasad, Dinesh;Vidyarthi, Ambarish Sharan
    • Interdisciplinary Bio Central
    • /
    • v.2 no.3
    • /
    • pp.8.1-8.5
    • /
    • 2010
  • Introduction: Recently identified human homologues of ALKB protein have shown the activity of DNA damaging drugs, used for cancer therapy. Bioinformatics study of hABH2 and hABH3 had led to the discovery of a novel DNA repair mechanism. Very little is known about structure and function of hABH4, one of the members of this superfamily. Therefore, in present study we are intended to predict its structure and function through various bioinformatics tools. Materials and Methods: Modeling was done with modeler 9v7 to predict the 3D structure of the hABH4 protein. This model was validated with the program Procheck using Ramachandran plot statistics and was submitted to PMDB with ID PM0076284. The 3d2GO server was used to predict the functions. Residues at protein ligand and protein RNA binding sites were predicted with 3dLigandSite and KYG programs respectively. Results and Discussion: 3-D model of hABH4, ALKBH4.B99990003.pdb was predicted and evaluated. Validation result showed that 96.4 % residues lies in favored and additional allowed region of Ramachandran plot. Ligand binding residues prediction showed four Ligand clusters, having 24 ligands in cluster 1. Importantly, conserved pattern of Glu196-X-Pro198- Xn-His254 in the functional domain was detected. DNA and RNA binding sites were also predicted in the model. Conclusion and Prospects: The predicted and validated model of human homologue hABH4 resulted from this study may unveil the mechanism of DNA damage repair in human and accelerate the research on designing of appropriate inhibitors aiding in chemotherapy and cancer related diseases.

ROM(Reducing Opposed Multilobed) Flap Repair for the Treatment of Medium Sized Skin Lesion (ROM(Reducing Opposed Multilobed) 피판을 이용한 중간 크기 피부병변의 치험례)

  • Cho, Jong Je;Hong, Yoon Gi;Seo, Sang Won;Chang, Choong Hyun
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.748-752
    • /
    • 2006
  • Purpose:Circular skin lesions between 10 and 35 mm in diameter generate problems often. Direct closure of the lesion risks excessive wound tension or wound dehiscence. Skin grafts heal slowly and often remain unsightly. Traditional skin flaps have a limited role. We treated this circular medium-sized skin lesion(10 - 35 mm sized) by reducing opposed multilobed(ROM) flap. Methods: ROM flap involves a series of semicircular lobes extending both cephalic and caudal from the defect. Direction of the semicircular multilobed flap is set parallel to relaxed skin tension line(RSTL) to minimize scar formation. First semicircle is drawn 60% in diameter of the defect. Second semicircles are drawn at the cephalic and caudal aspects of the original semicircles. These semicircles are 60% in diameter of the first semicircle. Additional semicircles are repeatedly drawn until the tension of skin flaps becomes free. ROM flap has a length-to-base ratio of 0.5 resulting in lower theoretical risk of end flap necrosis than a random pattern flap with a large ratio. The technique involves lobes most distant from the primary defect being transposed in turn closer to the defect. Results: The ROM flap reduces skin tension concerns, lowers the risk of flap necrosis and allows for quicker and more aesthetic healing. Results were generally good and major complications, such as dehiscence, infection, or delayed healing, did not occur. Conclusion: ROM flap repair allows the plastic surgeon an additional option when faced with a circular medium-sized skin lesion.

Non-invasive Fdlow-up of Pulmonary artey by EBT Other Palliatrve Shunt Operatin (청색증형 선천성 심질환아의 고식적 수술 이후 EBT에 의한 폐혈관계이 비침습적 추적 검사)

  • 김민정;박영환;홍유선;이종균;최규옥;조범구
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.7-19
    • /
    • 2000
  • Background :To assess the accuracy of Electron-Beam Tomography(EBT) in following evaluation of the pulmonary vascular system after a shunt operation in the cyanotic con-genital heart disease with pulmonary stenosis or pulmonary atresia. Material and Method : Sixteen patients(M:F=11:5) who received Blalock-Taussig(n=8) bidirectional cavo-pulmonary shunt(n=10) and unifocalization (n=2) were ncluded in the study. We evaluated the patency of the shunt the morphology of intrapericardial and hilar pulmonary arteries(PA) peripheral pulmonary vascularity by background lung attenuation and the abundance of arterial & venous collateral. Angiography(n=12) and echocardiography(n=20) were used as the gold standard for the comparison of EBT results. Result: EBT was consistent with angiogram/ echo in 100% of the evaluation for the patency of the shunt and in 12(by angiogram 100%) and 19(by echo 95%) for the detection the hypoplasia stenosis or interruption of central PA In measuring of PA EBT and angiogram corrlated(r=0.91) better than EBT-echo(r=0.88) or echo-angiogram(r=0.72) Abundant systemic arterial collateral were noted in 4 and venous collateral in 3 cases. In evaluating the peripheral pulmonary vascularity the homogenous and normal-ranged lung attenuation(m=6) decreased but homo-genous attenuation(n=1) segment-by-sgment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) segment-by-segment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) and venous congestion(n=2) were observed nd 12 of them were compatible with the blood flow pattern revealed by cardiac catheterization. Conclusion: EBT was accurate in the integrated evaluation of the pulmonary vascular system after the shunt including the patency of the shunt operaion the morphology and dimension of the central and hilar PAs and the loco-regional pulmonary flow in the lung parenchyma. It suggests the useful information about the need of secondary shunt operation the proper timing time for total repair and the need of interventional procedure prior to total repair.

  • PDF

Differential Localisation of PARP-1 N-Terminal Fragment in PARP-1+/+ and PARP-1-/- Murine Cells

  • Rajiah, Ida Rachel;Skepper, Jeremy
    • Molecules and Cells
    • /
    • v.37 no.7
    • /
    • pp.526-531
    • /
    • 2014
  • Human PARP family consists of 17 members of which PARP-1 is a prominent member and plays a key role in DNA repair pathways. It has an N-terminal DNA-binding domain (DBD) encompassing the nuclear localisation signal (NLS), central automodification domain and C-terminal catalytic domain. PARP-1 accounts for majority of poly-(ADP-ribose) polymer synthesis that upon binding to numerous proteins including PARP itself modulates their activity. Reduced PARP-1 activity in ageing human samples and its deficiency leading to telomere shortening has been reported. Hence for cell survival, maintenance of genomic integrity and longevity presence of intact PARP-1 in the nucleus is paramount. Although localisation of full-length and truncated PARP-1 in PARP-1 proficient cells is well documented, subcellular distribution of PARP-1 fragments in the absence of endogenous PARP-1 is not known. Here we report the differential localisation of PARP-1 Nterminal fragment encompassing NLS in PARP-$1^{+/+}$ and PARP-$1^{-/-}$ mouse embryo fibroblasts by live imaging of cells transiently expressing EGFP tagged fragment. In PARP-$1^{+/+}$ cells the fragment localises to the nuclei presenting a granular pattern. Furthermore, it is densely packaged in the midsections of the nucleus. In contrast, the fragment localises exclusively to the cytoplasm in PARP-$1^{-/-}$ cells. Flourescence intensity analysis further confirmed this observation indicating that the N-terminal fragment requires endogenous PARP-1 for its nuclear transport. Our study illustrates the trafficking role of PARP-1 independently of its enzymatic activity and highlights the possibility that full-length PARP-1 may play a key role in the nuclear transport of its siblings and other molecules.

Anterior Shoulder Dislocation with Massive Rotator Cuff tear and Axillary Nerve Injury - 4 Cases Report - (광범위 회전근개 파열 및 액와신경 손상을 동반한 견관절 전방탈구 - 4례 보고 -)

  • Kim Do-Yung;Park Hyun-Chul;Park Yong-Wook;Lee Sang-Soo;Suh Dong-Hyun;Kang Seung-Wan
    • Clinics in Shoulder and Elbow
    • /
    • v.7 no.2
    • /
    • pp.98-102
    • /
    • 2004
  • The terrible triad of the shoulder, a combination of anterior shoulder dislocation, massive rotator cuff tear and neurologic injury, is rare. We experienced 4 patients with this condition who were treated with a rotator cuff repair. The mean age was 65 years. Follow-up averaged 27 months. All patients had a history of redislocation after initial traumatic shoulder dislocation and were evaluated with electromyography and magnetic resonance imaging. At the operation, massive rotator cuff tear and hypertrophy of the long head of the biceps were found in all patients. Clinically, 3 patients achieved recovery of their nerve injury by 3 months postoperatively and the final results were fair. In one patient, there was no recovery of deltoid function and this case was rated as a failure. For this injury pattern, the prognosis appears to be dependent on eventual nerve recovery when the rotator cuff has been repaired early.