DOI QR코드

DOI QR Code

Minimal Medial-row Tie with Suture-bridge Technique for Medium to Large Rotator Cuff Tears

  • Lee, Hyun Il (Department of Orthopedic Surgery, Gangneung Asan Hospital, University of Ulsan Collage of Medicine) ;
  • Ryu, Ho Young (Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Shim, Sang-Jun (Department of Orthopedic Surgery, Gangneung Asan Hospital, University of Ulsan Collage of Medicine) ;
  • Yoo, Jae Chul (Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine)
  • Received : 2014.09.26
  • Accepted : 2014.12.13
  • Published : 2015.12.31

Abstract

Background: The purpose of this study was to evaluate the postoperative magnetic resonance imaging (MRI) results of minimal-tying (one medial-row tie among 4 medial-row sutures) on the medial-row in double-row suture-bridge configuration ($2{\times}2$ anchor with $4{\times}4$ suture stands). Methods: From 2011 March to 2012 July, 79 patients underwent arthroscopic rotator cuff repair using $2{\times}2$ anchor double-row configuration. The mean age was 61.3 years (range, 31-81 years). Two double-loaded suture anchors were used for medial-row. Four medial-row stitches were made with only one medial-row knot-tying (the most anterior suture). Lateral-row was secured using the conventional suture-bridge anchor technique; all 4 strands were used for each anchor. Repair integrity was evaluated with MRI at mean 6.2 months postoperatively. Retear and the pattern of retear, change of fatty infiltration, and muscle atrophy of supraspinatus were evaluated using pre- and postoperative MRI. Results: Repaired tendon integrity was 38 for type I, 30 for type II, 6 for type III, 4 for type IV, and 1 for type V, according to Sugaya classification. Considering type IV/V as retear, the rate was 6.3% (5 out of 79 patients). Medial cuff failure was observed in 4 patients. Fatty atrophy of supraspinatus was significantly improved postoperatively according to Goutallier grading (p=0.01). The level of muscle atrophy of supraspinatus was not changed significantly after surgery. Conclusions: Minimal tying technique with suture configuration of four-by-four strand double-row suture-bridge yielded a lower retear rate (6.3%) in medium to large rotator cuff tears.

Keywords

References

  1. Burkhart SS, Cole BJ. Bridging self-reinforcing double-row rotator cuff repair: we really are doing better. Arthroscopy. 2010; 26(5):677-80. https://doi.org/10.1016/j.arthro.2010.02.007
  2. Pauly S, Kieser B, Schill A, Gerhardt C, Scheibel M. Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations. Arthroscopy. 2010;26(10):1281-8. https://doi.org/10.1016/j.arthro.2010.02.013
  3. Park MC, Elattrache NS, Ahmad CS, Tibone JE. "Transosseousequivalent"rotator cuff repair technique. Arthroscopy. 2006; 22(12):1360.e1-5.
  4. Cho NS, Lee BG, Rhee YG. Arthroscopic rotator cuff repair using a suture bridge technique: is the repair integrity actually maintained? Am J Sports Med. 2011;39(10):2108-16. https://doi.org/10.1177/0363546510397171
  5. Cho NS, Yi JW, Lee BG, Rhee YG. Retear patterns after arthroscopic rotator cuff repair: single-row versus suture bridge technique. Am J Sports Med. 2010;38(4):664-71. https://doi.org/10.1177/0363546509350081
  6. Gerhardt C, Hug K, Pauly S, Marnitz T, Scheibel M. Arthroscopic single-row modified mason-allen repair versus doublerow suture bridge reconstruction for supraspinatus tendon tears: a matched-pair analysis. Am J Sports Med. 2012;40(12): 2777-85. https://doi.org/10.1177/0363546512462123
  7. Mall NA, Lee AS, Chahal J, et al. Transosseous-equivalent rotator cuff repair: a systematic review on the biomechanical importance of tying the medial row. Arthroscopy. 2013; 29(2):377-86. https://doi.org/10.1016/j.arthro.2012.11.008
  8. Rhee YG, Cho NS, Parke CS. Arthroscopic rotator cuff repair using modified Mason-Allen medial row stitch: knotless versus knot-tying suture bridge technique. Am J Sports Med. 2012;40(11):2440-7. https://doi.org/10.1177/0363546512459170
  9. Voigt C, Bosse C, Vosshenrich R, Schulz AP, Lill H. Arthroscopic supraspinatus tendon repair with suture-bridging technique: functional outcome and magnetic resonance imaging. Am J Sports Med. 2010;38(5):983-91. https://doi.org/10.1177/0363546509359063
  10. DeOrio JK, Cofield RH. Results of a second attempt at surgical repair of a failed initial rotator-cuff repair. J Bone Joint Surg Am. 1984;66(4):563-7. https://doi.org/10.2106/00004623-198466040-00011
  11. Yoo JC, Ahn JH, Yang JH, Koh KH, Choi SH, Yoon YC. Correlation of arthroscopic repairability of large to massive rotator cuff tears with preoperative magnetic resonance imaging scans. Arthroscopy. 2009;25(6):573-82. https://doi.org/10.1016/j.arthro.2008.12.015
  12. Sugaya H, Maeda K, Matsuki K, Moriishi J. Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy. 2005; 21(11):1307-16. https://doi.org/10.1016/j.arthro.2005.08.011
  13. Goutallier D, Postel JM, Gleyze P, Leguilloux P, Van Driessche S. Influence of cuff muscle fatty degeneration on anatomic and functional outcomes after simple suture of full-thickness tears. J Shoulder Elbow Surg. 2003;12(6):550-4. https://doi.org/10.1016/S1058-2746(03)00211-8
  14. Warner JJ, Higgins L, Parsons IM 4th, Dowdy P. Diagnosis and treatment of anterosuperior rotator cuff tears. J Shoulder Elbow Surg. 2001;10(1):37-46. https://doi.org/10.1067/mse.2001.112022
  15. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159-74. https://doi.org/10.2307/2529310
  16. Itoi E, Berglund LJ, Grabowski JJ, et al. Tensile properties of the supraspinatus tendon. J Orthop Res. 1995;13(4):578-84. https://doi.org/10.1002/jor.1100130413
  17. Lake SP, Miller KS, Elliott DM, Soslowsky LJ. Effect of fiber distribution and realignment on the nonlinear and inhomogeneous mechanical properties of human supraspinatus tendon under longitudinal tensile loading. J Orthop Res. 2009;27(12):1596-602. https://doi.org/10.1002/jor.20938
  18. Cummins CA, Murrell GA. Mode of failure for rotator cuff repair with suture anchors identified at revision surgery. J Shoulder Elbow Surg. 2003;12(2):128-33. https://doi.org/10.1067/mse.2003.21
  19. Choi CH, Kim SK, Cho MR, et al. Functional outcomes and structural integrity after double-pulley suture bridge rotator cuff repair using serial ultrasonographic examination. J Shoulder Elbow Surg. 2012;21(12):1753-63. https://doi.org/10.1016/j.jse.2011.12.012
  20. Park JY, Siti HT, Keum JS, Moon SG, Oh KS. Does an arthroscopic suture bridge technique maintain repair integrity?: a serial evaluation by ultrasonography. Clin Orthop Relat Res. 2010;468(6):1578-87. https://doi.org/10.1007/s11999-009-0990-8
  21. Frank JB, ElAttrache NS, Dines JS, Blackburn A, Crues J, Tibone JE. Repair site integrity after arthroscopic transosseousequivalent suture-bridge rotator cuff repair. Am J Sports Med. 2008;36(8):1496-503. https://doi.org/10.1177/0363546507313574
  22. Kim KC, Shin HD, Cha SM, Lee WY. Comparison of repair integrity and functional outcomes for 3 arthroscopic suture bridge rotator cuff repair techniques. Am J Sports Med. 2013; 41(2):271-7. https://doi.org/10.1177/0363546512468278
  23. Gerber C, Fuchs B, Hodler J. The results of repair of massive tears of the rotator cuff. J Bone Joint Surg Am. 2000;82(4):505-15. https://doi.org/10.2106/00004623-200004000-00006
  24. Jost B, Pfirrmann CW, Gerber C, Switzerland Z. Clinical outcome after structural failure of rotator cuff repairs. J Bone Joint Surg Am. 2000;82(3):304-14. https://doi.org/10.1302/0301-620X.82B2.10931
  25. Thomazeau H, Boukobza E, Morcet N, Chaperon J, Langlais F. Prediction of rotator cuff repair results by magnetic resonance imaging. Clin Orthop Relat Res. 1997;(344):275-83.
  26. Saridakis P, Jones G. Outcomes of single-row and double-row arthroscopic rotator cuff repair: a systematic review. J Bone Joint Surg Am. 2010;92(3):732-42. https://doi.org/10.2106/JBJS.I.01295
  27. Trantalis JN, Boorman RS, Pletsch K, Lo IK. Medial rotator cuff failure after arthroscopic double-row rotator cuff repair. Arthroscopy. 2008;24(6):727-31. https://doi.org/10.1016/j.arthro.2008.03.009
  28. Lee KW, Seo DW, Bae KW, Choy WS. Clinical and radiological evaluation after arthroscopic rotator cuff repair using suture bridge technique. Clin Orthop Surg. 2013;5(4):306-13. https://doi.org/10.4055/cios.2013.5.4.306
  29. Cheon SJ, Hur JO, Suh JT, Yoo CI. The integrity after arthroscopically repairing the rotator cuff tendon using the suture bridge technique. J Korean Orthop Assoc. 2011;46(1):1-9. https://doi.org/10.4055/jkoa.2011.46.1.1
  30. Chung SW, Kim SH, Tae SK, Yoon JP, Choi JA, Oh JH. Is the supraspinatus muscle atrophy truly irreversible after surgical repair of rotator cuff tears? Clin Orthop Surg. 2013;5(1):55-65. https://doi.org/10.4055/cios.2013.5.1.55

Cited by

  1. Does the Dog-Ear or Bird-Beak Deformity Remodel After Rotator Cuff Repair? vol.48, pp.7, 2015, https://doi.org/10.1177/0363546520915199