• Title/Summary/Keyword: Patient-specific modeling

Search Result 22, Processing Time 0.022 seconds

The Effect of Behavior Modification on Enhancing Patient Adherence to Tuberculosis Treatment Regimens (Video프로그램을 통한 환자교육이 결핵환자 치료이행행위에 미치는 영향)

  • 정은리
    • Journal of Korean Academy of Nursing
    • /
    • v.26 no.3
    • /
    • pp.697-708
    • /
    • 1996
  • Most efforts to improve tuberculosis treatment adherence target the patient and his or her behavior. This study examined the effects of behavioral modification training for these patients. Based on Bandura's behavioral principles of modeling, intervention strategies using a video program were devised to elicit specific patient target behaviors considered to improve patients' adherence to tuberculosis treatment regimens. A random assignment, two-group(experimental group and control group) research design including 81 subjects was used. The main outcomes measured were pill taking measured with the Medication Event Monitoring System(MEMS) Medication Cap, patients' self-efficacy, and their knowledge of tuberculosis. The findings are as follows : 1) There was a significant difference between the experimental group and the control group in patients' feelings of self-efficacy. That is, the patients who received the behavior modification program showed greater feeling of self-efficacy to initiate and change their behavior for the tuberculosis treatment regimen than the patients who did not receive the program(t=3.51, p=0.01). 2) There was a significant difference between the experimental group and the control group in patients' knowledge of tuberculosis. That is, the patients who received the behavior modification program showed higher level of knowledge of tuberculosis than the patients who did not receive the program(t=2.15, p=0.03) 3) There was a significant difference between the experimental group and the control group in patients' adherence to tuberculosis treatment regimens. That is, the patients who received the behavior modification program showed greater adherence to the treatment regimens than the patients who did not receive the program(t=5.11, p=0.00). The study findings provided useful insights into nursing practice, particularly in planning intervention strategies aimed at enhancing patients' adherence in tuberculosis that may also be relevant to other chronic diseases with patient adherence problems.

  • PDF

Application of Patient-Specific 3D-Printed Orthopedic Splint for Bone Fracture in Small Breed Dogs

  • Kwangsik Jang;Eun Joo Jang;Yo Han Min;Kyung Mi Shim;Chunsik Bae;Seong Soo Kang;Se Eun Kim
    • Journal of Veterinary Clinics
    • /
    • v.40 no.4
    • /
    • pp.268-275
    • /
    • 2023
  • In this paper, we designed 3D-printed orthopedic splint models for patient-specific external coaptation on fracture healing and analyzed the stability of the models through finite element method (FEM) analysis under compressive load conditions. Polylactic acid (PLA) and acrylonitrile-butadiene-styrene (ABS) based 3D splint models of the thicknesses 1, 3, 5 and 7 mm were designed, and Peak von Mises stress (PVMS) and maximum displacement (MD) of the models were analyzed by FEM under compressive loads of 50, 100, 150, and 200 N. The FEM results indicated that PVMS and MD values, regardless of material, had a negative correlation with the thickness of the models and a positive correlation with the compressive load. There was a risk of splint deformation under conditions more extreme than 100 N with 5 mm thickness. For successful clinical application of 3D-printed orthopedic splints in veterinary medicine, it is recommended that the splint should be produced not less than 5 mm thickness. Also, it is expected to be stable when the splint is applied to situations with a compressive load of 100 N or less. There is an advantage of overcoming the limitations of the existing bandage method through 3D-printing technology as well as verifying the stability through 3D modeling before application. Such 3D printing technology will be widely used in veterinary medicine and various fields as well as orthopedics.

A Review of Organ Dose Calculation Tools for Patients Undergoing Computed Tomography Scans

  • Lee, Choonsik
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.151-159
    • /
    • 2021
  • Background: Computed tomography (CT) is one of the crucial diagnostic tools in modern medicine. However, careful monitoring of radiation dose for CT patients is essential since the procedure involves ionizing radiation, a known carcinogen. Materials and Methods: The most desirable CT dose descriptor for risk analysis is the organ absorbed dose. A variety of CT organ dose calculators currently available were reviewed in this article. Results and Discussion: Key common elements included in CT dose calculators were discussed and compared, such as computational human phantoms, CT scanner models, organ dose database, effective dose calculation methods, tube current modulation modeling, and user interface platforms. Conclusion: It is envisioned that more research needs to be conducted to more accurately map CT coverage on computational human phantoms, to automatically segment organs and tissues for patient-specific dose calculations, and to accurately estimate radiation dose in the cone beam computed tomography process during image-guided radiation therapy.

Novel nomogram-based integrated gonadotropin therapy individualization in in vitro fertilization/intracytoplasmic sperm injection: A modeling approach

  • Ebid, Abdel Hameed IM;Motaleb, Sara M Abdel;Mostafa, Mahmoud I;Soliman, Mahmoud MA
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.48 no.2
    • /
    • pp.163-173
    • /
    • 2021
  • Objective: This study aimed to characterize a validated model for predicting oocyte retrieval in controlled ovarian stimulation (COS) and to construct model-based nomograms for assistance in clinical decision-making regarding the gonadotropin protocol and dose. Methods: This observational, retrospective, cohort study included 636 women with primary unexplained infertility and a normal menstrual cycle who were attempting assisted reproductive therapy for the first time. The enrolled women were split into an index group (n=497) for model building and a validation group (n=139). The primary outcome was absolute oocyte count. The dose-response relationship was tested using modified Poisson, negative binomial, hybrid Poisson-Emax, and linear models. The validation group was similarly analyzed, and its results were compared to that of the index group. Results: The Poisson model with the log-link function demonstrated superior predictive performance and precision (Akaike information criterion, 2,704; λ=8.27; relative standard error (λ)=2.02%). The covariate analysis included women's age (p<0.001), antral follicle count (p<0.001), basal follicle-stimulating hormone level (p<0.001), gonadotropin dose (p=0.042), and protocol type (p=0.002 and p<0.001 for short and antagonist protocols, respectively). The estimates from 500 bootstrap samples were close to those of the original model. The validation group showed model assessment metrics comparable to the index model. Based on the fitted model, a static nomogram was built to improve visualization. In addition, a dynamic electronic tool was created for convenience of use. Conclusion: Based on our validated model, nomograms were constructed to help clinicians individualize the stimulation protocol and gonadotropin doses in COS cycles.

Palatal obturator restoration of a cleft palate patient with velopharyngeal insufficiency: a clinical report (구개인두 기능부전을 갖는 구개열 환자에서 폐쇄장치를 이용한 보철 치료 증례)

  • Heo, Yu-Ri;Kim, Jong-Wook;Lee, Gyeong-Je;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.353-360
    • /
    • 2013
  • Cleft lip and palate is congenital deformity in oral and maxillofacial area. Normal soft palate has velopharyngeal closure action by connecting oral cavity and nasal cavity at rest and moving upward at swallowing and specific pronunciation. Cleft palate patients with velopharyngeal insufficiency have difficulty in mastication, swallowing and pronunciation because velopharyngeal closure is incomplete. At this time, a prosthetic device used to cover palate defects is called a palatal obturator. A palatal obturator separates oral cavity and nasal cavity and recovers pronunciation, mastication, swallowing and esthetic function. The purpose of this case study is to report the results because it reaches a satisfactory result in functional and esthetic aspects through functional impression procedures using modeling compound and tissue conditioner for restoration of a cleft palate patient with velopharyngeal insufficiency.

An Integrative Review of Home Care Service for Pregnant Women, Mothers, Infants, and Toddlers in Vulnerable Group (취약계층 임산부·어머니·영유아 대상 방문건강관리서비스에 대한 통합적 문헌고찰)

  • Kim, Dasom;Lee, Insook
    • Journal of Korean Academy of Nursing
    • /
    • v.47 no.5
    • /
    • pp.577-588
    • /
    • 2017
  • Purpose: This study was intended to integrate the evidence of home care service intervention for mothers and children in vulnerable groups through an integrative literature review. Methods: We searched the MEDLINE (PubMED), EMBASE, Cochrane Central Register of Controlled Trials, CINAHL, DBpia databases. The quality of the articles was assessed by one doctoral researcher and verified by one professor of community health nursing who had participated in the systematic review of literature. A framework was developed to identify the intervention patterns in the selected papers and categorize various elements. The extracted intervention elements were grouped into potential themes, which were verified by assessors on whether they clearly reflected the interventions in the papers. Results: Among 878 searched papers, we selected 16 papers after excluding literature that does not satisfy the selection criteria and quality evaluation. The intervention elements of 16 selected papers were categorized into six themes. The extracted intervention elements were divided into the themes of Patient-specific/Situation-specific care planning and intervention, Emphasis on self care competency, Intense home visit by developmental milestone, Reinforcing and modeling mother-child attachment, Communication and interaction across the intervention, Linkage with community resource and multidisciplinary approach. Conclusion: As a result of the analysis of proper interventions of home care services for mothers and children in vulnerable groups, it was found that it is necessary to consider indispensable intervention elements that can standardize the quality of home care services, and conduct studies on developing intervention programs based on the elements.

Scale Development and Model Validation for the Process of Exercise Engagement for People with Prediabetes

  • Chang, Shu-Chuan;Yeh, Hsiu-Chen;Kuo, Yu-Lun
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.2
    • /
    • pp.298-312
    • /
    • 2020
  • Purpose: This study had two objectives: 1) to develop a scale for the process of exercise engagement (SPEE) for prediabetic individuals (PDIs); 2) to validate a structural model for the process of exercise engagement for PDIs. Methods: A cross-sectional survey with simple random sampling was conducted from September 2013 to December 2015 (in Taiwan). A total of 310 PDIs were enrolled for scale development and model validation via item analysis, factor analyses, and structural equation modeling. The Kuo model was used as the basis for developing the Chinese version of the SPEE for PDIs. Results: The SPEE contains five subscales with a total of twenty-one items that account for 54.9% to 65.9% of the total variance explained for assessing participants' process of engagement during exercise. For Kuo model validation, the model measures indicated goodness of fit between the Kuo model and sample data. Analysis further revealed a direct effect between the creating health blueprints (CHB) stage and the spontaneous regular exercise (SRE) stage (β=.60). Conclusion: The SPEE includes five subscales for assessing the psychological transition and behavioral expression at each stage of the process of exercise engagement for PDIs. The SPEE for people with prediabetes provides deeper insights into the factors of behavioral change stages that are required to initiate long-term health care outcomes and avoid developing diabetes. These insights are significant as they allow for patient-specific mapping and behavior modification to effect exercise.

Bayesian Network Model to Evaluate the Effectiveness of Continuous Positive Airway Pressure Treatment of Sleep Apnea

  • Ryynanen, Olli-Pekka;Leppanen, Timo;Kekolahti, Pekka;Mervaala, Esa;Toyras, Juha
    • Healthcare Informatics Research
    • /
    • v.24 no.4
    • /
    • pp.346-358
    • /
    • 2018
  • Objectives: The association between obstructive sleep apnea (OSA) and mortality or serious cardiovascular events over a long period of time is not clearly understood. The aim of this observational study was to estimate the clinical effectiveness of continuous positive airway pressure (CPAP) treatment on an outcome variable combining mortality, acute myocardial infarction (AMI), and cerebrovascular insult (CVI) during a follow-up period of 15.5 years ($186{\pm}58$ months). Methods: The data set consisted of 978 patients with an apnea-hypopnea index (AHI) ${\geq}5.0$. One-third had used CPAP treatment. For the first time, a data-driven causal Bayesian network (DDBN) and a hypothesis-driven causal Bayesian network (HDBN) were used to investigate the effectiveness of CPAP. Results: In the DDBN, coronary heart disease (CHD), congestive heart failure (CHF), and diuretic use were directly associated with the outcome variable. Sleep apnea parameters and CPAP treatment had no direct association with the outcome variable. In the HDBN, CPAP treatment showed an average improvement of 5.3 percentage points in the outcome. The greatest improvement was seen in patients aged ${\leq}55$ years. The effect of CPAP treatment was weaker in older patients (>55 years) and in patients with CHD. In CHF patients, CPAP treatment was associated with an increased risk of mortality, AMI, or CVI. Conclusions: The effectiveness of CPAP is modest in younger patients. Long-term effectiveness is limited in older patients and in patients with heart disease (CHD or CHF).

A Study of Smart Healthcare Services Software Quality Satisfaction Rating System based on QoS(Quality of Service) Measurement Model (QoS(Quality of Service) 측정 모델을 참조한 스마트헬스케어서비스 소프트웨어 품질만족도 평가체계)

  • Noh, Si-Choon;Song, Eun-Jee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.1
    • /
    • pp.149-154
    • /
    • 2014
  • Quality is the value that can be measured by observing the characteristics of the service quantity or quality. QoS is predictable service traffic to a minimum requirements what passed in network. In the course of Smart Medical Information System Development there exist some functional requirements to satisfy quality objectives. The functional smart domains of healthcare information systems consists of Patient Module, a smart sensing and communication domain, RFID Tag Readers and the behavior domain, Homecare Station Domain, Clinical Station. This study is performed on evaluation methodology of u-health service satisfaction quality of each domain. In this paper QoS metrics and the quality of medical information requirements, functional requirements are separated by. Quality parameters consists of six items and the functional requirements and quality requirements 20 details the five items and consist of 20 detailed items. On this study the quality evaluation methodology of Korean smart health information quality assessment matrix 2 - factor evaluation method is proposed. The overall framework of this paper is organizing the specific criteria of quality of medical information system and modeling quality evaluation process under all smart environment.

Verification of Gated Radiation Therapy: Dosimetric Impact of Residual Motion (여닫이형 방사선 치료의 검증: 잔여 움직임의 선량적 영향)

  • Yeo, Inhwan;Jung, Jae Won
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.128-138
    • /
    • 2014
  • In gated radiation therapy (gRT), due to residual motion, beam delivery is intended to irradiate not only the true extent of disease, but also neighboring normal tissues. It is desired that the delivery covers the true extent (i.e. clinical target volume or CTV) as a minimum, although target moves under dose delivery. The objectives of our study are to validate if the intended dose is surely delivered to the true target in gRT and to quantitatively understand the trend of dose delivery on it and neighboring normal tissues when gating window (GW), motion amplitude (MA), and CTV size changes. To fulfill the objectives, experimental and computational studies have been designed and performed. A custom-made phantom with rectangle- and pyramid-shaped targets (CTVs) on a moving platform was scanned for four-dimensional imaging. Various GWs were selected and image integration was performed to generate targets (internal target volume or ITV) for planning that included the CTVs and internal margins (IM). The planning was done conventionally for the rectangle target and IMRT optimization was done for the pyramid target. Dose evaluation was then performed on a diode array aligned perpendicularly to the gated beams through measurements and computational modeling of dose delivery under motion. This study has quantitatively demonstrated and analytically interpreted the impact of residual motion including penumbral broadening for both targets, perturbed but secured dose coverage on the CTV, and significant doses delivered in the neighboring normal tissues. Dose volume histogram analyses also demonstrated and interpreted the trend of dose coverage: for ITV, it increased as GW or MA decreased or CTV size increased; for IM, it increased as GW or MA decreased; for the neighboring normal tissue, opposite trend to that of IM was observed. This study has provided a clear understanding on the impact of the residual motion and proved that if breathing is reproducible gRT is secure despite discontinuous delivery and target motion. The procedures and computational model can be used for commissioning, routine quality assurance, and patient-specific validation of gRT. More work needs to be done for patient-specific dose reconstruction on CT images.