• Title/Summary/Keyword: Patient skin dose

Search Result 147, Processing Time 0.033 seconds

In Vivo Dosimetry with MOSFET Detector during Radiotherapy (방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법)

  • Kim Won-Taek;Ki Yong-Gan;Kwon Soo-Il;Lim Sang-Wook;Huh Hyun-Do;Lee Suk;Kwon Byung-Hyun;Kim Dong-Won;Cho Sam-Ju
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In Vivo dosimetry is a method to evaluate the radiotherapy; it is used to find the dosimetric and mechanical errors of radiotherapy unit. In this study, on-line In Vivo dosimetry was enabled by measuring the skin dose with MOSFET detectors attached to patient's skin during treatment. MOSFET dosimeters were found to be reproducible and independent on beam directions. MOSFET detectors were positioned on patient's skin underneath of the dose build-up material which was used to minimize dosimetric error. Delivered dose calculated by the plan verification function embedded in the radiotherapy treatment planning system (RTPs), was compared with measured data point by point. The dependency of MOSFET detector used in this study for energy and dose rate agrees with the specification provided by manufacturer within 2% error. Comparing the measured and the calculated point doses of each patient, discrepancy was within 5%. It was enabled to verify the IMRT by using MOSFET detector. However, skin dosimetry using conventional ion chamber and diode detector is limited to the simple radiotherapy.

  • PDF

Study of Acute Myelocytic Leukemia Patient Treatment That Used Total Skin Electron Beam (Total Skin Electron Beam을 이용한 급성 골수성 백혈병 환자 치료에 대한 연구)

  • Lee, Sang-Ryul;Kang, Min-Kyu;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.152-158
    • /
    • 2009
  • Total Skin Electron Beam Therapy (TSEBT) of linear accelerator has become use so as to be useful, 2~9 MeV of energy territories came to be used with mycosis fungoides and cutaneous lymphomas in the superficial lesion treatment which covers the major portion of the body. I treat a patient to Stanford technique in this study, and it is $60^{\circ}$ around the patients whom Stanford technique irradiated electronic beam to a linear accelerator in horizontal directions and there is a way a standard of TSEBT treat it to six located field (anterior, posterior, and four obliques) becoming. An each field does horizontally it and consist to beam of the two component which fitted the center to a suitable angle. a patient treats it to three dual field a day in order to make short treatment time. when a first day, we treat one dual field at anterior position and two dual field at posterior position. when the second day, treat one dual field at posterior position and two dual field at anterior position. Therefore, six dual field is finished in perfect periodic two days. we made cylindrical acrylic phantom, and I inserted a dosimeter film between phantom. in order to measure a dose distribution calculation before treat a patient, and a patient checked it in six field directions that got from a treatment. It is after that thermoluminescent dosimetry (TLD) as it uses Rando phantom and then measurement dose distribution in six field directions after attaching at chest, the right and left flank, a back after irradiation.

  • PDF

Evaluation of the Efficiency of the Foxtail Millet Vacuum Cushion in Skin Cancer Radiation Treatment (자체 제작한 Foxtail Millet Vacuum Cushion의 광자선 피부암 치료 시 유용성 검증)

  • Choi, Shin-Cheol;Lee, Kyung-Jae;Jung, Sung-Min;Oh, Tae-Seong;Park, Jong-Il;Shin, Hyun-Kyo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.189-196
    • /
    • 2012
  • Purpose: The sufficiency of skin dose and the reemergence of patient set-up position to the success of skin cancer radiation treatment is a very important element. But the conventional methods to increase the skin dose were used to vacuum cushion, bolus and water tank have several weak points. For this reason, we producted Foxtail Millet Vacuum Cushion and evaluated the efficiency of the Foxtail Millet Vacuum Cushion in skin cancer Radiation treatment. Materials and Methods: We measured absolute dose for 3 materials (Foxtail Millet Vacuum Cushion, bolus and solid water phantom) and compared each dose distribution. We irradiated 6 MV 100 MU photon radiation to every material of 1 cm, 2 cm, 3 cm thickness at three times. We measured absolute dose and compared dose distribution. Finally we inspected the CT simulation and radiation therapy planing using the Foxtail Millet Vacuum Cushion. Results: Absolute dose of Foxtail Millet Vacuum Cushion was similar to absolute dose of bolus and solid water phantom's result in each thickness. it Showed only the difference of 0.1~0.2% between each material. Also the same result in dose distribution comparison. About 97% of the dose distribution was within the margin of error in the prescribed ranges ($100{\pm}3%$), and achieved the enough skin dose (Gross Tumor Volume dose : $100{\pm}5%$) in radiation therapy planing. Conclusion: We evaluated important fact that Foxtail Millet Vacuum Cushion is no shortage of time to replace the soft tissue equivalent material and normal vacuum cushion at the low energy radiation transmittance. Foxtail Millet Vacuum Cushion can simultaneously achieve the enough skin dose in radiation therapy planing with maintaining normal vacuum cushion' function. Therefore as above We think that Foxtail Millet Vacuum Cushion is very useful in skin cancer radiation treatment.

  • PDF

A Study on the Dosimetry of the Total Skin Electron Beam Therapy in Cutaneous T-Cell Lymphoma (피부 T 세포림프종의 전 피부 전자선 치료를 위한 dosimetry 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.57-65
    • /
    • 1996
  • Total Skin Electron Beam Therapy (TSEBT) is one of the most effective treatment methods for superficially disseminated skin cancer or cutaneous T-cell lymphoma. We have treated a patient with cutaneous T-cell lymphoma. We have used Stanford technique using six dual field. The nominal energy of electron beam was 4MeV. SSD was 390cm and the gantry angles of dual fields were 76$^{\circ}$ and 104$^{\circ}$. The dose profiles of single field and dual fields were measured with films and a Farmer type ion chamber. The field uniformity was 10% over the patient's surface. During treatment, the patient was placed in six different positions for homogenous dose distribution over the body surface. The areas not directly exposed to the path of the electron beam (soles of feet, perineum and vertex of scalp) were boosted with 7MeV electron beam. During the treatment, lens, fingernails and toenails were shielded.

  • PDF

A Study of Radiation Doses to the Patient and Medical Team at Embolization Procedures

  • Castilho, Alvaro Vilas Boas;Szjenfeld, Denis;Nalli, Darcio;Fornazari, Vinicius;Moreira, Antonio Carlos;Medeiros, Regina Bitelli
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.110-117
    • /
    • 2019
  • Background: This study aimed to estimate occupational doses and patient peak skin doses (PSDs) during interventional radiology procedures. Materials and Methods: We examined data from brain embolization (n = 30), hepatic chemoembolization (n = 50), and uterine embolization (n = 12). The PSDs were measured using radiochromic film around the patient's head (group 1) or abdominal/pelvic region (group 2). Acquisition technical data and kerma-area products (KAP) were also recorded. Occupational doses were measured using $Instadose^{TM}$ dosimeters near the left eye region (LER), chest, and left ankle. Results and Discussion: The third quartile (median) KAP values were $408.1(235.3)Gy{\cdot}cm^2$ for group 1 and $584.4(449.4)Gy{\cdot}cm^2$ for group 2. The average PSDs were greatest during vascular procedures, reaching 1,004.4 (786.4) mGy, and the highest PSD was 2,352.6 mGy (during hepatic chemoembolization). The third quartile (median) occupational doses were 0.35 (0.21) mSv at the LER, 0.25 (0.15) mSv at the chest, and 1.47 (0.64) mSv at the left ankle. Occupational doses at the LER were higher than at the chest, which highlights the importance of protective glasses and suspended shields. The occupational doses at the ankle region were also high, which highlights the importance of using a lead-lined curtain attached to the table. Conclusion: The results indicate that physicians can reach, for eye region, the weekly occupational dose limit after around 15 procedures, even when using proper protection. The average PSD values were below the threshold for tissue reactions, although the complexity of these procedures emphasises the importance of considering related risks.

A Case of Pyoderma Gangrenosum in Rheumotoid Arthritis Patient (류마티스 관절염 환자에서 발생한 괴저성 농피증 1예)

  • Ryu, Dong-Hwan;Kwon, Chang-Mo;Lee, Jung-Hun;Hong, Young-Hun;Lee, Choong-Ki
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.1
    • /
    • pp.79-84
    • /
    • 2003
  • Pyoderma gangrenosum is uncommon neutrophilic dermatosis characterized by richness of the mature neutrophilic polynuclear dermal infiltrate. Pyoderma gangrenosum is associated with variable diseases, most commonly inflammatory bowel disease, hematological diseases, malignancies, but it is reported rarely in rheumatoid arthritis. We report a case of pyoderma gangrenosum in rheumoid arthritis patient. A 50-year-old woman admitted to our hospital due to painful pretibial ulcerative skin lesions. She had been treated as rheumatoid arthritis for 8 years. At admission, body temperature was $36.5^{\circ}C$ and other vital sign was unremarkable. Physical examination revealed right pretibial ulceration, multiple pustules on left pretibial area and both palms. Laboratory studies revealed WBC count 7,600/uL (neutrophils 60.3%, eosinophil 3.2%), hemoglobin 11.4 g/dL, platelet count 319,000/uL, ESR 65 mm/hour. Other lab findings were also unremarkable. Skin biopsy was done, which showed dense dermal infiltrate of neutrophils and wound culture were negative. By 8 weeks after systemic high dose corticosteroid (1 mg/kg/day), cyclosporine A (5 mg/kg/day), sulfasalazine 2 g therapy, symptoms and skin ulceration were being improved. Without skin relapse, she is followed up our hospital with low dose corticosteroid and sulfasalazine.

  • PDF

Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR (표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가)

  • Kim, Sang-Tae;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.

The Usefulness of Bolus of Radiation Therapy in Patients with Whole Breast Cancer

  • Min, Jung-Whan;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.99-103
    • /
    • 2011
  • Radiation Therapy has been used in the treatment of breast cancer for over 80 years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internam mammary nodes and supraclavicular nodes. The purpose of this study is treated breast cancer patient to use 6 MV, 10 MV with bolus so that we observe changing of skin dose and evaluate those usefulness. Using woman's phantom, after CT simulate scanning, Through RTP system to make treatment plan, select three any place. And then, we measure that dose rate. After moving the phantom to linac, we put for TLD to three point same as RTP system which we put on the phantom. We exposed 6 MV, 10 MV with bolus and without so that it is measured dose by TLD device(4000 Harshaw). As a reult expose 6 MV,10 MV, it differences 10%, 15% according to bolus and withoout bolus where lateral point from RAO, LPO beam, other one is 20% where the furthest from both beams. To use bolus in the hospital is material to include closely part at skin among tissue of breast cancer. Acquired skin dose from RTP system is uncertainity. So it has to test another system likely TLD or other dosimetry system. Also exposed field of breast cancer is included inhomogeneity such as lung, bone and so on. Therefore it has to be accomplished a dose calculating of inhomogeneity part from treatment plan.

  • PDF

Usefulness of Silicon Bolus Using 3D Printing of Head and Neck Patients (두경부 환자의 3D Printing을 이용한 Silicon Bolus의 유용성)

  • Kwon, Kyung-Tae;Lee, Yong-Ki;Won, Young-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.909-916
    • /
    • 2019
  • Radiation therapy of oral and head and neck cancers often involves skin in the therapeutic range, and the use of bolus is frequently used. Dose irregularities provide dose uncertainty in patient application. In this study, the physical properties of patients with gel bolus, poly lactic acid (PLA), and silicon using 3D printing were fabricated. Dose uncertainties arising from the actual radiation dose delivery were measured. As a result, PLA bolus was stable in the Common irregularities. Silicon bolus may be useful for patients with severe irregularities or frequent changes in patient's body shape.

Extracranial systemic antitumor response through the abscopal effect induced by brain radiation in a patient with metastatic melanoma

  • D'Andrea, Mark A.;Reddy, G.K.
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.302-308
    • /
    • 2019
  • The abscopal effect is a term that has been used to describe the phenomenon in which localized radiation therapy treatment of a tumor lesion triggers a spontaneous regression of metastatic lesion(s) at a non-irradiated distant site(s). Radiation therapy induced abscopal effects are believed to be mediated by activation and stimulation of the immune system. However, due to the brain's distinctive immune microenvironment, extracranial abscopal responses following cranial radiation therapy have rarely been reported. In this report, we describe the case of 42-year-old female patient with metastatic melanoma who experienced an abscopal response following her cranial radiation therapy for her brain metastasis. The patient initially presented with a stage III melanoma of the right upper skin of her back. Approximately 5 years after her diagnosis, the patient developed a large metastatic lesion in her upper right pectoral region of her chest wall and axilla. Since the patient's tumor was positive for BRAF and MEK, targeted therapy with dabrafenib and trametinib was initiated. However, the patient experienced central nervous system (CNS) symptoms of headache and disequilibrium and developed brain metastases prior to the start of targeted therapy. The patient received radiation therapy to a dose of 30 Gy delivered in 15 fractions to her brain lesions while the patient was on dabrafenib and trametinib therapy. The patient's CNS metastases improved significantly within weeks of her therapy. The patient's non-irradiated large extracranial chest mass and axilla mass also shrank substantially demonstrating the abscopal effect during her CNS radiation therapy. Following radiation therapy of her residual chest lesions, the patient was disease free clinically and her CNS lesions had regressed. However, when the radiation therapy ended and the patient continued her targeted therapy alone, recurrence outside of her previously treated fields was noted. The disease recurrence could be due to the possibility of developing BRAF resistance clones to the BRAF targeted therapy. The patient died eventually due to wide spread systemic disease recurrence despite targeted therapy.