• Title/Summary/Keyword: Patient

Search Result 32,926, Processing Time 0.07 seconds

Clinical Experiences for Cardiac Myxomas (심장 점액종의 임상적 고찰)

  • Lee, Geun-Dong;Lee, Jae-Won;Jung, Jae-Seung;Jung, Sung-Ho;Je, Hyoung-Gon;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.703-709
    • /
    • 2008
  • Background: Diagnosis and treatment are often successful in the setting of cardiac myxomas. However, cardiac myxomas can lead to catastrophic complications, due to intracardiac obstruction and embolism preoperatively, and can recur postoperatively. Material and Method: We retrospectively reviewed the clinical characteristics, surgical treatment, and recurrence data of 85 patients who underwent cardiac myxoma surgery at Asan Medical Center between November 1994 and June 2007. We analyzed the morphologic characteristics of 58 patients with left atrial myxomas and determined the development of functional mitral valve stenosis and systemic embolism through reviewing the results of preoperative echo-cardiograms to find potential preoperative risk factors. Result: Twenty-seven (31.8%) patients were men, and 58 (68.2%) were women. The mean patient age was $54.5{\pm}14.3$ years. Preoperative symptoms included obstructive symptoms in 41 (48.2%) patients, signs of embolism in 19 (22.4%), constitutional symptoms in 8 (9.4%), and no symptoms in 19 (20.0%). Among the 58 patients with left atrial myxomas, the mean maximal tumor diameter was $4.3{\pm}1.8$ (range $1.1{\sim}8\;cm$)cm. Twenty-six (44.8%) patients had a prolapsing type, defined as a tumor mobile enough to move down. to the mitral. annular plane during diastole, and 32 (55.2%) had villous type, defined as a tumor consisting of multiple fine villous extensions on the surface. Twelve (20.7%) patients had severe functional mitral valve stenosis, and 15 (25.9%) had systemic embolism preoperatively. The incidence of severe functional mitral valve stenosis was significantly higher in patients with the prolapsing type than in those with the non-prolapsing type (p=0.001). The mean maximal tumor diameter in patients with severe functional mitral valve stenosis was $5.1{\pm}1.0\;cm$, significantly larger than that seen in patients without severe functional mitral valve stenosis (p=0.041). The incidence of systemic embolism was significantly higher in patients with the villous type than in those with the smooth type (p=0.006). Postoperative complications were noted in 6 (7.1%) patients, and early mortality was noted in 1 (1.2%). The mean postoperative follow-up duration was $36.2{\pm}37.5$ months, with recurrence reported in 2(2.4%) patients during the follow-up period. The disease free interval were 48, 12 months, respectively. Conclusion: Surgical treatment for cardiac myxomas was performed safely, and long-term prognosis was good. In patients with left atrial myxoma, close attention should be maintained and surgery should be performed promptly in those of prolapsing type, those with large maximal diameter in order to prevent severe functional mitral valve stenosis, and those of villous type in order to prevent systemic embolism. Echocardiography should be followed serially in order to detect recurrence.

Statistical Analysis of Operating Efficiency and Failures of a Medical Linear Accelerator for Ten Years (선형가속기의 10년간 가동률과 고장률에 관한 통계분석)

  • Ju Sang Gyu;Huh Seung Jae;Han Youngyih;Seo Jeong Min;Kim Won Kyou;Kim Tae Jong;Shin Eun Hyuk;Park Ju Young;Yeo Inhwan J.;Choi David R.;Ahn Yong Chan;Park Won;Lim Do Hoon
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.186-193
    • /
    • 2005
  • Purpose: To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2l00C over a ten year period were retrospectively analyzed. Materials and Methods: The failures were classified according to the involved functional subunits, with each class rated Into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Results: Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for $20\%$ of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and $83\%$ of the expected values, respectively. The operating efficiency was maintained at $95\%$ or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. Conclusion: The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. Wore rigorous equipment maintenance Is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the qualify of patient treatment.

Radiation Therapy for Carcinoma of the Oropharynx (구인두암의 방사선치료)

  • Park, In-Kyu;Kim, Jae-Choel
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.95-103
    • /
    • 1996
  • Purpose : A retrospective analysis for patients with oropharyngeal carcinoma who were treated with radiation was performed to assess the results of treatment and patterns of failure, and to identify the factors that might influence survival. materials and methods : From March 1985 through June 1993, 53 patients with oropharyngeal carcinoma were treated with either radiation therapy alone or combination of neoadjuvant chemotherapy and radiation therapy at the Department of Radiation Oncology, Kyungpook National University Hospital. Patients' ages ranged from 31 to 73 years with a median age of 54 years. There were 47 men and 6 women, Forty-two Patients ($79.2\%$) had squamous cell carcinoma, 10 patients ($18.9\%$) had undifferentiated carcinoma and 1 patient ($19\%$) had adenoid cystic carcinoma. There were 2 patients with stage I, 12 patients with stage II, 12 Patients with stage III and 27 patients with stage IV. According to the TNM classification, patients were distributed as follows: T1 7, T2 28, T3 10, T4 7, TX 1, and N0 17, Nl 13, N2 21, N3 2. The primary tumor sites were tonsillar region in 36 patients ($67.9\%$), base of the tongue in 12 patients ($22.6\%$), and soft palate in 5 patients ($9.4\%$). Twenty-five patients were treated with radiation therapy alone and twenty-eight Patients were treated with one to three courses of chemotherapy followed by radiation therapy. Chemotherapeutic regimens used were either CF (cisplatin and 5-fluorouracil) or CVB (cisplatin, vincristine and bleomycin). Radiation therapy was delivered 180-200 cGy daily, five times a week using 6 MV X-ray with or without 8-10 MeV electron beams A tumor dose ranged from 4500 cGy to 7740 cGy with a median dose of 7100 cGy. The follow-up time ranged from 4 months to 99 months with a median of 21 months. Results : Thirty-seven patients ($69.8\%$) achieved a CR (complete response) and PR (partial response) in 16 patients ($30.2\%$) after radiation therapy. The overall survival rates were $47\%$ at 2 years and $42\%$ at 3 years, respectively. The median survival time was 23 months. Overall stage (p=0.02) and response to radiation therapy (p=0.004) were significant prognostic factors for overall survival. The 2-year disease-free survival rate was $45.5\%$. T-stage (p=0.03), N-stage (p=0.04) and overall stage (P=0.04) were significant prognostic factors for disease-free survival. Age, sex, histology, primary site of the tumor, radiation dose, combination of chemotherapy were not significantly associated with disease-free survival. Among evaluable 32 Patients with CR to radiation therapy, 12 patients were considered to have failed Among these, 8 patients failed locoregionally and 4 Patients failed distantly. Conclusion : T-stage, N-stage and overall stage were significant prognostic factors for disease-free survival in the treatment of oropharyngeal cancer Since locoregional failure was the predominant pattern of relapse, potential methods to improve locoregional control with radiation therapy should be attempted. More controlled clinical, trials should be completed before acceptance of chemotherapy as a part of treatment of oropharyngeal carcinoma.

  • PDF

Combined Chemotherapy and Radiation Therapy in Limited Disease Small-Cell Lung Cancer (국한성 소세포 폐암에서 항암 화학 및 흉부 방사선치료의 병합요법 적응)

  • Kim Moon Kyung;Ahn Yong Chan;Park Keunchil;Lim Do Hoon;Huh Seung Jae;Kim Dae Yong;Shin Kyung Hwan;Lee Kyu Chan;Kwon O Jung
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.9-15
    • /
    • 1999
  • Purpose : This is a retrospective study to evaluate the response rate, acute toxicity, and survival rate of a combined chemotherapy and radiation therapy in limited disease small cell lung cancer, Materials and Methods : Firty-six patients with limited disease small-cell lung cancer who underwent combined chemotherapy and radiation therapy between October 1994 and April 1998 were evaluated. Six cycles of chemotherapy were planned either using a VIP regimen etoposide, ifosfamide, and cis-platin) or a EP regimen (etoposide and cis-platin). Thoracic radiation therapy was planned to deli- ver 44 Gy using 1 OMV X-ray, starting concurrently with chemotherapy. Response was evaluated 4 weeks after the completion of the planned chemotherapy and radiation therapy, and the prophylaetic cranial irradiation was planned only for the patients with complete responses. Acute toxicity was evaluated using the SWOG toxicity criteria, and the overall survival and disease-free survival were calculated using the Kaplan-Meier Method. Results : The median follow-up period was 16 months (range:2 to 41 months). Complete response was achieved En 30 (65$\%$) patients, of which 22 patients received prophylactic cranial irradiations. Acute toxicities over grade III were granulocytopenia in 23 (50$\%$), anemia in 17 (37$\%$), thrombo- cytopenia in nine (20$\%$), alopecia in nine (20$\%$), nausea/vomiting in five (11$\%$), and peripheral neuropathy in one (2$\%$). Chemotherapy was delayed in one patient, and the chemotherapy doses were reduced in 58 (24$\%$) out of the total 246 cycles. No radiation esophagitis over grade 111 was observed, while interruption during radiation therapy for a mean of 8.3 days occurred in 21 patients. The local recurrences were observed in 8 patients and local progressions were in 6 patients, and the distant metastases in 17 patients. Among these, four patients had both the local relapse and the distant metastasis. Brain was the most common metastatic site (10 patients), followed by the liver as the next common site (4 patients). The overall and progression-free survival rates were 79$\%$ and 55$\%$ in 1 year, and 45'/) and 32% in 2 years, respectively, and the median survival was 23 months. Conclusion : Relatively satisfactory local control and suwival rates were achieved after the combined chemotherapy and radiation therapy with mild to moderate acute morbidities in limited disease small cell lung cancer.

  • PDF

Individualized Determination of Lower Margin in Pelvic Radiation Field after Low Anterior Resection for Rectal Cancer Resulted in Equivalent Local Control and Radiation Volume Reduction Compared with Traditional Method (하전방 절제술을 시행한 직장암 환자에서 방사선조사 영역 하연의 개별화)

  • Park Suk Won;Ahn Yong Chan;Huh Seung Jae;Chun Ho Kyung;Kang Won Ki;Kim Dae Yong;Lim Do Hoon;Noh Young Ju;Lee Jung Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.3
    • /
    • pp.194-199
    • /
    • 2000
  • Purpose : Then determining the lower margin of post-operative pelvic radiation therapy field according to the traditional method (recommended by Gunderson), the organs located in the low pelvic cavity and the perineum are vulnerable to unnecessary radiation. This study evaluated the effect of individualized determination of the lower margin at 2 cm to 3 cm below the anastomotic site on the failure patterns. Materials and Methods . Authors included ぉ patients with modified Astler-Coiler (MAC) stages from B2 through C3, who received low anterior resection and post-operative pelvic radiation therapy from Sept. 1994 to May 1998 at Samsung Medical Center, Sungkyunkwan University. The numbers of male and female patients were 44 and 44, and the median age was 57 years (range: 32-81 years). Three field technique (posterior-anterior and bilateral portals) by 6, 10, 15 MV X-rays was used to deliver 4,500 cGy to the whole pelvis followed by Sn cGy's small field boost to the tumor bed over 5.5 weeks. Sixteen patients received radiation therapy by traditional field margin determination, and the lower margin was set either at the low margin of the obturator foramen or at 2 cm to 3 cm below the anastomotic site, whichever is lower. In 72 patients, the lower margin was set at 2 cm to 3 cm below the anastomotic site, irrespectively of the obturator foramen, by which the reduction of radiation volume was possible in 55 patients ($76\%$). Authors evaluated and compared survival, local control, and disease-free survival rates of these two groups. Results : The median follow-up period was 27 months (range : 7-58 months). MAC stages B2 in 32($36\%$), B3 in 2 ($2\%$), Cl in 2 ($2\%$), C2 in 50 ($57\%$), and C3 in 2 ($2\%$) Patients, respectively. The entire patients' overall survival rates at 2 and 4 years were $94\%$ and $68\%$, respectively, and disease-free survival rates at 2 and 4 years were $86\%$ and $58\%$, respectively. The first failure sites were local only in 4, distant only in 14, and combined local and distant in 1 patient, respectively. There was no significant difference with respect to local control and disease-free survival rates ( p=0.42, p=0.68) between two groups of different lower margin determination policies. Conclusion : The new concept in the individualized determination of the lower margin depending on the anastomotic site has led to the equivalent local control and disease-free survival rates, and is expected to contribute to the reduction of unnecessary radiation-related morbidity by reduction of radiation volume, compared with the traditional method of lower margin determination.

  • PDF

The Benefit of Individualized Custom Bolus in the Postmastectomy Radiation Therapy : Numerical Analysis with 3-D Treatment Planning (유방전절제술 후 방사선치료를 위한 조직보상체 개발 및 3차원 치료계획을 통한 유용성 분석)

  • Cho Jae Ho;Cho Kwang Hwan;Keum Kichang;Han Yongyih;Kim Yong Bae;Chu Sung Sil;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.82-93
    • /
    • 2003
  • Purpose : To reduce the Irradiation dose to the lungs and heart in the case of chest wail irradiation using an oppositional electron beam, we used an Individualized custom bolus, which was precisely designed to compensate for the differences In chest wall thickness. The benefits were evaluated by comparing the normal tissue complication probablilties (NTCPS) and dose statistics both with and without boluses. Materials and Methods : Boluses were made, and their effects evaluated in ten patients treated using the reverse hockey-stick technique. The electron beam energy was determined so as to administer 80% of the irradiation prescription dose to the deepest lung-chest wall border, which was usually located at the internal mammary lymph node chain. An individualized custom bolus was prepared to compensate for a chest wall thinner than the prescription depth by meticulously measuring the chest wall thickness at 1 emf intervals on the planning CT Images. A second planning CT was obtained overlying the individuailzed custom bolus for each patient's chest wall. 3-D treatment planning was peformed using ADAC-Pinnacle$^{3}$ for all patients with and without bolus. NTCPS based on 'the Lyman-Kutcher' model were analyzed and the mean, maximum, minimum doses, V$_{50}$ and V$_{95}$ for 4he heari and lungs were computed. Results .The average NTCPS in the ipsliateral lung showed a statistically significant reduction (p<0.01), from 80.2${\pm}$3.43% to 47.7${\pm}$4.61%, with the use of the individualized custom boluses. The mean lung irradiation dose to the ipsilateral iung was also significantly reduced by about 430 cGy, Trom 2757 cGy to 2,327 cGy (p<0.01). The V$_{50}$ and V$_{95}$ in the ipsilateral lung markedly decreased from the averages of 54.5 and 17.4% to 45.3 and 11.0%, respectively. The V$_{50}$ and V$_{95}$ In the heart also decreased from the averages of 16.8 and 6.1% to 9.8% and 2.2%, respectively. The NTCP In the contralateral lung and the heart were 0%, even for the cases with no bolus because of the small effective mean radiation volume values of 4.4 and 7.1%, respectively Conclusion : The use of an Individualized custom bolus in the radiotherapy of postrnastectorny chest wall reduced the NTCP of the ipsilateral lung by about 24.5 to 40.5%, which can improve the complication free cure probability of breast cancer patients.

An integrated Method of New Casuistry and Specified Principlism as Nursing Ethics Methodology (새로운 간호윤리학 방법론;통합된 사례방법론)

  • Um, Young-Rhan
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.51-64
    • /
    • 1997
  • The purpose of the study was to introduce an integrated approach of new Casuistry and specified principlism in resolving ethical problems and studying nursing ethics. In studying clinical ethics and nursing ethics, there is no systematic research method. While nurses often experience ethical dilemmas in practice, much of previous research on nursing ethics has focused merely on describing the existing problems. In addition, ethists presented theoretical analysis and critics rather than providing the specific problems solving strategies. There is a need in clinical situations for an integrated method which can provide the objective description for existing problem situations as well as specific problem solving methods. We inherit two distinct ways of discussing ethical issues. One of these frames these issues in terms of principles, rules, and other general ideas; the other focuses on the specific features of particular kinds of moral cases. In the first way general ethical rules relate to specific moral cases in a theoretical manner, with universal rules serving as "axioms" from which particular moral judgments are deduced as theorems. In the seconds, this relation is frankly practical. with general moral rules serving as "maxims", which can be fully understood only in terms of the paradigmatic cases that define their meaning and force. Theoretical arguments are structured in ways that free them from any dependence on the circumstances of their presentation and ensure them a validity of a kind that is not affected by the practical context of use. In formal arguments particular conclusions are deduced from("entailed by") the initial axioms or universal principles that are the apex of the argument. So the truth or certainty that attaches to those axioms flows downward to the specific instances to be "proved". In the language of formal logic, the axioms are major premises, the facts that specify the present instance are minor premises, and the conclusion to be "proved" is deduced (follows necessarily) from the initial presises. Practical arguments, by contrast, involve a wider range of factors than formal deductions and are read with an eye to their occasion of use. Instead of aiming at strict entailments, they draw on the outcomes of previous experience, carrying over the procedures used to resolve earlier problems and reapply them in new problmatic situations. Practical arguments depend for their power on how closely the present circumstances resemble those of the earlier precedent cases for which this particular type of argument was originally devised. So. in practical arguments, the truths and certitudes established in the precedent cases pass sideways, so as to provide "resolutions" of later problems. In the language of rational analysis, the facts of the present case define the gounds on which any resolution must be based; the general considerations that carried wight in similar situations provide warrants that help settle future cases. So the resolution of any problem holds good presumptively; its strengh depends on the similarities between the present case and the prededents; and its soundness can be challenged (or rebutted) in situations that are recognized ans exceptional. Jonsen & Toulmin (1988), and Jonsen (1991) introduce New Casuistry as a practical method. The oxford English Dictionary defines casuistry quite accurately as "that part of ethics which resolves cases of conscience, applying the general rules of religion and morality to particular instances in which circumstances alter cases or in which there appears to be a conflict of duties." They modified the casuistry of the medieval ages to use in clinical situations which is characterized by "the typology of cases and the analogy as an inference method". A case is the unit of analysis. The structure of case was made with interaction of situation and moral rules. The situation is what surrounds or stands around. The moral rule is the essence of case. The analogy can be objective because "the grounds, the warrants, the theoretical backing, the modal qualifiers" are identified in the cases. The specified principlism was the method that Degrazia (1992) integrated the principlism and the specification introduced by Richardson (1990). In this method, the principle is specified by adding information about limitations of the scope and restricting the range of the principle. This should be substantive qualifications. The integrated method is an combination of the New Casuistry and the specified principlism. For example, the study was "Ethical problems experienced by nurses in the care of terminally ill patients"(Um, 1994). A semi-structured in-depth interview was conducted for fifteen nurses who mainly took care of terminally ill patients. The first stage, twenty one cases were identified as relevant to the topic, and then were classified to four types of problems. For instance, one of these types was the patient's refusal of care. The second stage, the ethical problems in the case were defined, and then the case was analyzed. This was to analyze the reasons, the ethical values, and the related ethical principles in the cases. Then the interpretation was synthetically done by integration of the result of analysis and the situation. The third stage was the ordering phase of the cases, which was done according to the result of the interpretation and the common principles in the cases. The first two stages describe the methodology of new casuistry, and the final stage was for the methodology of the specified principlism. The common principles were the principle of autonomy and the principle of caring. The principle of autonomy was specified; when competent patients refused care, nurse should discontinue the care to respect for the patients' decision. The principle of caring was also specified; when the competent patients refused care, nurses should continue to provide the care in spite of the patients' refusal to preserve their life. These specification may lead the opposite behavior, which emphasizes the importance of nurse's will and intentions to make their decision in the clinical situations.

  • PDF

A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION (임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구)

  • Kim Pyung-Il;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Diagnosis of Obstructive Sleep Apnea Syndrome Using Overnight Oximetry Measurement (혈중산소포화도검사를 이용한 폐쇄성 수면무호흡증의 흡증의 진단)

  • Youn, Tak;Park, Doo-Heum;Choi, Kwang-Ho;Kim, Yong-Sik;Woo, Jong-Inn;Kwon, Jun-Soo;Ha, Kyoo-Seob;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.34-40
    • /
    • 2002
  • Objectives: The gold standard for diagnosing obstructive sleep apnea syndrome (OSAS) is nocturnal polysomnography (NPSG). This is rather expensive and somewhat inconvenient, however, and consequently simpler and cheaper alternatives to NPSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. In this study, we have evaluated whether oximetry alone can be used to diagnose or screen OSAS. The diagnostic performance of an analysis algorithm using arterial oxygen saturation ($SaO_2$) base on 'dip index', mean of $SaO_2$, and CT90 (the percentage of time spent at $SaO_2$<90%) was compared with that of NPSG. Methods: Fifty-six patients referred for NPSG to the Division of Sleep Studies at Seoul National University Hospital, were randomly selected. For each patient, NPSG with oximetry was carried out. We obtained three variables from the oximetry data such as the dip index most linearly correlated with respiratory disturbance index (RDI) from NPSG, mean $SaO_2$, and CT90 with diagnosis from NPSG. In each case, sensitivity, specificity and positive and negative predictive values of oximetry data were calculated. Results: Thirty-nine patients out of fifty-six patients were diagnosed as OSAS with NPSG. Mean RDI was 17.5, mean $SaO_2$ was 94.9%, and mean CT90 was 5.1%. The dip index [4%-4sec] was most linearly correlated with RDI (r=0.861). With dip index [4%-4sec]${\geq}2$ as diagnostic criteria, we obtained sensitivity of 0.95, specificity of 0.71, positive predictive value of 0.88, and negative predictive value of 0.86. Using mean $SaO_2{\leq}97%$, we obtained sensitivity of 0.95, specificity of 0.41, positive predictive value of 0.79, and negative predictive value of 0.78. Using $CT90{\geq}5%$, we obtained sensitivity of 0.28, specificity of 1.00, positive predictive value of 1.00, and negative predictive value of 0.38. Conclusions: The dip index [4%-4sec] and mean $SaO_2{\leq}97%$ obtained from nocturnal oximetry data are helpful in diagnosis of OSAS. CT90${\leq}$5% can be also used in excluding OSAS.

  • PDF