• Title/Summary/Keyword: Patient's position

Search Result 578, Processing Time 0.022 seconds

A study of the Ethical Values of Korean Nurses (간호사의 윤리적 가치관에 관한 연구)

  • 이영숙
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.2
    • /
    • pp.249-270
    • /
    • 1990
  • The purpose of this study is to identify whether ethical values of korean nurses are deontological or utilitarian. Nurse's ethical value questionnaire was developed from review of literature and interview of nurses in the clinical settings. Content validity was tested from three nursing faculties and staffs. Ethical problems are categorized into four areas : 1) human life area 2) nurse-patient relationship area 3) nurse - nursing task relationship area 4) nurse-collegue relationship area The data were obtained from the 404 nurses in the clinical settings from Feb. to Mar. in 1990 by ethical value questionnaire. The analysis of data was done by Pearson's correlation coefficient, t-test, anova. The results of this study were as follows : 1. The ethical values of human life slightly took up the position of utilitarian. 2. The ethical values of nurse - patient relationships slightly took up deontological position. 3. The ethical values of nurse - nursing task relationships slightly took up deontological position. 4. The ethical values of nurse - colleague relationships greatly took up deontological position. 5. The ethics of nurses related to demographic characteristics of religion, attitude of nursing, ethical standards, education level and post. Those who have religion took up more deontological position than those who have not. Those who have positive attitude of nursing and firm ethical standards took up more deontological position than those who have not. Those who have higher education level and post took up more deontological position than those who have not.

  • PDF

Utility Comparison of Chest Lateral Decubitus Projection with AP and PA Position (흉부 측와위 촬영 시 전후방향과 후전방향 검사의 유용성 비교)

  • Choi, Guirack
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.233-238
    • /
    • 2013
  • Chest lateral decubitus radiation exposure PA be carried out in general, but emergency patient or the patient's discomfort in the body examination had a lot of inconvenience. In this study, we compared AP and PA image quality, patient safety, and analysis of the examination effectiveness between the two tests was to evaluate the usefulness. Pleurisy or pneumothorax in patients with suspected or diagnosed chest lateral decubitus radiation exposure 30 consecutive patients (male 20 patients, 10 females) were included in the study. Image quality evaluation method microstructure of lung, wide areas of diagnosis, a clear air-fluid interface, the patient rotate, cardiac shadow and sharp diaphragmatic was based on Department of Radiology specialist, division of pulmonology resident blind test was evaluated by four people. Chest decubitus by radiation exposure the AP and PA position examination the usefulness of comparative analysis Image quality in the AP and PA, whereas there was no significant difference in attitude, Stability of the patient and Radiation's examination efficiency AP position compared to the position of PA scores were higher. PA position does not require a examination may be of AP position in a position to suggest that.

Study of Patient's Position to Reduce Late Complications in High Dose Rate Intracavitary Radiation of the Uterine Cervix Cancer (자궁경부암의 고선량율 강내 방사선치료 시 부작용을 줄이기 위한 적정 치료 자세의 연구)

  • Yun, Hyong-Geun;Shin, Kyo-Chul
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.477-483
    • /
    • 1998
  • Purpose : Radiation proctitis and radiation cystitis are frequent and problematic late complications in patients treated with radiation for the uterine cervix cancer. Authors tried to find out the better patient's position in high dose rate intracavitary radiation to reduce the radiation dose of bladder and rectum. Materials and Methods : In 13 patients, Foley Catheters were inserted to patient's bladder and rectum and were ballooned with radioopaque dye. After insertion of a tandem and two ovoids, semi-orthogonal anteroposterior and lateral films were taken in both lithotomy and supine position. The rectal point and bladder point were defined according to the criteria recommended in the ICRU Report 38 with modification. Using these films, all patients' bladder and rectal dose were calculated in both positions (the radiation dose of A point was set to 400 cGy). And also, the distance of bladder and rectum from uterine cervical os was calculated in both positions. Results : The average radiation dose of rectum was 240.7 cGy in lithotomy position and 278.3 cGy in supine position, and the average radiation dose of bladder was 303.5 cGy in lithotomy position and 255.8 cGy in supine position. After the paired t-test, the radiation dose of rectum in lithotomy position was marginally significantly lower than that in supine position, while the radiation dose of bladder in lithotomy position was significantly higher than that in supine position. On the other hand, the average distance between rectum and cervical os was 35.2 mm in lithotomy position and 32.3 mm in supine position. and the average distance between bladder and cervical os was 30.4 mm in lithotomy position and 34.0 mm in supine position. After the paired t-test. the distance between rectum and cervical os in lithotomy position was significantly longer than that in supine position, while the distance between bladder and cervical os in lithotomy position was significantly shorter than that in supine position. Conclusion : The radiation dose of bladder can be reduced in supine position and the radiation dose of rectum can be reduced in lithotomy position, so we can choose appropriate position in each patient.

  • PDF

Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners (투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구)

  • Yang, Hae-Doo;Hong, Seon-Sook;Seong, Min-Sook;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

Quality Assurance System for Determination of Center Position in X-ray and Proton Irradiation Fields using a Stainless Ball and Imaging Plates in Proton Therapy at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.189-191
    • /
    • 2002
  • In the proton therapy using a gantry system, periodical verification of iso-center position is very important to assure precision of patient positioning system at any gantry angles in proton treatment. In the gantry system, there are three different types of iso-center; 1) in a geometrical view, 2) in an X-ray beam's eye view, 3) in a proton beam's eye view. Idealistically, they would be an identical point. They could, however, be different points. It may be a source of errors in patient positioning. At PMRC, we have established a system of verification for iso-center positions using a stainless ball of 2-cm in diameter and an imaging plate. This system provides the relation among a center of a patient target position, a center of proton irradiation field, and/or a center of X-ray field in accuracy of 50$\square$m in the 2) and 3) views, as images of a center of the stainless ball and a center of a 100 mm${\times}$100 mm-aperture brass collimator recorded on the imaging plate, which is setup at 1-cm behind the ball. In addition, it provides simultaneously the images of the ball and the collimator on an imaging intensifier (II), which is setup downstream of the proton or X-ray beam. We present a method of quality assurance (QA) for calibration of iso-center position in a rotation gantry system at PMRC and the performance of this system. A proton beam position on the 1$\^$st/ scatterer in the nozzle of the gantry affects less sensitive (reduced by a factor of 1/5) to the results of the iso-center position. The effect is systematically correctable. The effect of the nozzle (or the collimator) position is less than 0.5 mm at the maximum extraction (390 mm).

  • PDF

The Characteristics of Weight Bearing Ratio on Different Position of Ages Group (연령별 자세변화에 따른 하지체중지지율에 대한 특성)

  • Kwon, Hei-Jeoung;Hwang, Seong-Soo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.9-21
    • /
    • 2009
  • Purpose : To know how much weight bearing on left and right leg on 14 different positions. The second is to know how about different the weight bearing ratio on same positions of ages group. Methods : The third is to know how about changes the weight bearing ration between exercise group and non exercise group. The group of age is divided 20s, 30s, 40s, 50s, over the 60 years. The subjects are 93 males(44), females(49). Results : The ordering of ratio of weight bearing on one side leg is as follows: The position of the highest weight bearing ratio is one leg standing with the other leg on chair(right 0.82, left 0.81) and the position of lowest weight bearing ratio is hooklying with natural leg position(both legs 0.08). There are statistically significant difference between right and left leg of weight bearing ratio on the 6 positions among the 14 positions. As for the ages, there are statistically significant difference on 5 different positions of 20 ages body weight bearing ratio between right and left leg. But as for the 50 ages there are no statistically significant difference on all of 14 positions between right and left leg body weight bearing. As for the exercise group there are statistically significant difference on only one position of one leg standing with the other leg on chair between right and left weight bearing ratio. But as for non exercise group there are statistically significant difference on 4 positions between right and left weight bearing ratio. Conclusion : When the therapist exercise with patient's always considerate of patient's position and weight bearing ratio.

  • PDF

Which is the proper insertion method of laryngeal mask airway according to the rescuer's position? : Comparison between index finger insertion and thumb insertion (구조자의 위치에 따른 적절한 후두마스크기도기 삽입방법은 무엇일까? : 검지손가락법과 엄지손가락법의 비교)

  • Chun, Kyoung-Ha;Moon, Jun-Dong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.3
    • /
    • pp.7-16
    • /
    • 2017
  • Purpose: The purpose of the study was to investigate the effects of laryngeal mask airway (LMA) insertion from different positions, using different methods, on the quality of the insertion, for identifying a more convenient and effective insertion method. Methods: In a model ambulance, 30 paramedic students performed the LMA insertion procedure, in four different settings, combinations of the rescuer's position (at the head end of the patient, at the side of the patient), and insertion technique (index finger insertion, thumb insertion), in a randomized order. Quality of insertion index and convenience of use were measured. Results: The quality of insertion index (tidal volume, gastric insufflation, airway pressure, airway sealing pressure, midline positions, insertion success grade, and insertion time) were not significantly different among four different settings. However LMA insertion from the anterior (head) end, using the index finger method compared to the thumb method was found to be significantly more convenient. Conclusion: We recommend using the more convenient and familiar LMA insertion method, between index finger insertion and thumb insertion, regardless of rescuer's position.

Discrepancies in Soft Tissue Profile of Patients for Orthognathic Surgery between Preoperative Lateral Facial Photograph, Lateral Cephalogram and Supine Position on Operation Table

  • Jung, Young-Eun;Yang, Hoon-Joo;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.3
    • /
    • pp.180-185
    • /
    • 2012
  • Purpose: An accurate preoperative analysis of the patient is essential in orthognathic surgery in order to acquire superior results. In profile, the location of the chin's position may change according to the neck's inclination. This may ultimately affect the amount of surgical movement. During acquisition of cephalometric radiographs, or in supine position, there is a discrepancy in the neck's inclination. This means that there are also various discrepancies between the actual profile and the various preoperative profile images. In the clinical situation, the decision in performing genioplasty usually lies in the analysis of the patient's profile on the operating table at the final stages of orthognathic surgery. This study aims to analyze the different preoperative profile images and to compare their discrepancies. Methods: Fifty eight patients undergoing orthognathic surgery were chosen. These patients were divided into three groups according to angle's classification of malocclusion, as class I, II or III. The right profile of these patients in centric occlusion was taken in natural head position (NHP). This was set as the 'actual profile image.' Another right profile image was taken on the operating table after insertion of the nasotracheal intubation and with muscle relaxants in effect. This was also taken in centric occlusion. The angle (denoted 'A') between the soft tissue glabella-pognion and the true vertical plane was found in the above-mentioned profile images and in the cephalometric radiographs. The differences of these values were analyzed. Results: There were differences in Angle 'A' in all of the preoperative images. These values were however, not statistically significant. Conclusion: In order to gain an esthetic profile during orthognathic surgery, the NHP is shown to be the most reliable position. Images reproducing such head positions should be used in the treatment planning process.

A Study on the Effect of Time Lapse After Position Change and Abdominal Band on Pulmonary Function in the Cervical Cord Injuries (척수손상 환자의 자세 변화 후 시간경과와 복대사용이 폐기능에 미치는 영향)

  • Lee, Jae-Ho;Park, Chang-Il;Chon, Joong-Sun
    • Physical Therapy Korea
    • /
    • v.4 no.3
    • /
    • pp.17-33
    • /
    • 1997
  • The objective of this study was to identify pulmonary functional variations in relation to postural changes, lapse after changing position, and the use of abdominal band in the cervical cord injured. The subjects of this study were 19 quadriplegic patients who had been admitted to the department of the Rehabilitation Hospital, College of Medicine, Yousei University, from April, 1997 through May 3, 1997. A spiroanalyzer was used to measure pulmonary function in supine, standing, time after changing position, and recording to the position, application method, and tightness of the abdominal band. The data were analyzed by the repeated measure one-way ANOVA, and Wilcoxon signed rank test. The findings were as follows: 1. All phase of the patients' pulmonary function improved significantly in supine posture in contrast to standing (vital capacity by $0.46{\ell}$ and expiratory reserve volume by $0.09{\ell}$). 2. The longer the time lapsed from supine posture to standing, the patient's expiratory reserve volume, maximum ventilation volume, vital capacity, and forced expiratory volume increased. 3. When the patient lay in supine position, the maximum ventilation volume, vital capacity, and the forced vital capacity increased then the center line of the abdominal band was placed along iliac crest; on the other hand, when the patient was standing, placing the bottom line of the abdominal band along iliac crest increased the maximum ventilation volume, vital capacity, and forced expiratory volume. 4. In placing the abdominal band in the patients, leaving space between the top and bottom lines of the band helped increased in maximum ventilation volume, vital capacity, and forced vital capacity for patient in supine as well as in standing. 5. When placing the abdominal band to patients in supine posture, reducing the length of the band by 2.5% along the patient's waist line increased the patients' vital capacity, while reducing the length by 10% to patients in standing increased the maximum ventilation volume. The abdominal band should be placed in such a way that the bottom part of the band should be more tightly fastened while leaving enough room for a hand to be placed in between the body and the band for the top part of the hand. It should also be noted that in a supine position, the bottom line of the band should be placed along the iliac crest, while in standing, the center line should be placed along the iliac crest. The length of the band should also be reduced by 2.5% of the waist line in supine position, and in standing, the length should be reduced by 10%. It should also be noted that the pulmonary function of the patients should be measured at least 10 minutes after one position change.

  • PDF

Evaluation of the usefulness of IGRT(Image Guided Radiation Therapy) for markerless patients using SGPS(Surface-Guided Patient Setup) (표면유도환자셋업(Surface-Guided Patient Setup, SGPS)을 활용한 Markerless환자의 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)시 유용성 평가)

  • Lee, Kyeong-jae;Lee, Eung-man;Lee, Jeong-su;Kim, Da-yeon;Ko, Hyeon-jun;Choi, Shin-cheol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.109-116
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the usefulness of Surface-Guided Patient Setup by comparing the patient positioning accuracy when image-guided radiation therapy was used for Markerless patients(unmarked on the skin) using Surface-Guided Patient Setup and Marker patients(marked on the skin) using Laser-Based Patient Setup. Materials And Methods: The position error during IGRT was compared between a Markerless patient initially set up with SGPS using an optical surface scanning system using three cameras and a Marker patient initially set up with LBPS that aligns the laser with the marker drawn on the patient's skin. Both SGPS and LBPS were performed on 20 prostate cancer patients and 10 Stereotactic Radiation Surgery patients, respectively, and SGPS was performed on an additional 60 breast cancer patients. All were performed IGRT using CBCT or OBI. Position error of 6 degrees of freedom was obtained using Auto-Matching System, and comparison and analysis were performed using Offline-Review in the treatment planning system. Result: The difference between the root mean square (RMS) of SGPS and LBPS in prostate cancer patients was Vrt -0.02cm, Log -0.02cm, Lat 0.01cm, Pit -0.01°, Rol -0.01°, Rtn -0.01°, SRS patients was Vrt 0.02cm, Log -0.05cm, Lat 0.00cm, Pit -0.30°, Rol -0.15°, Rtn -0.33°. there was no significant difference between the two regions. According to the IGRT standard of breast cancer patients, RMS was Vrt 0.26, Log 0.21, Lat 0.15, Pit 0.81, Rol 0.49, Rtn 0.59. Conclusion:. As a result of this study, the position error value of SGPS compared to LBPS did not show a significant difference between prostate cancer patients and SRS patients. In the case of additionally performed SGPS breast cancer patients, the position error value was not large based on IGRT. Therefore, it is considered that it will be useful to replace LBPS with SGPS, which has the great advantage of not requiring patient skin marking..