Kim, T.H.;Kim, S.Y.;Park, J.D.;Kim, M.J.;Jeon, E.C.
Korean Journal of Computational Design and Engineering
/
v.11
no.6
/
pp.440-446
/
2006
This study relates to the effect of forming time of injection path on the total process. The whole process can be divided into build process of forming path of injection and after treatment process. The total time required for the whole process could be reduced by reducing the forming time of injection path using SLC file to correct the problems of STL file that is the basic file format for high speed molding devices. First of all, I verify the forming time of injection path according to the conditions of STL file during the formation of injection path. And I verify problems using STL file during formation of injection path. And then I tried to solve problems of STL file by comparing between the formation time of injection path and the existing method using SLC files.
Journal of the Korean Society for Precision Engineering
/
v.22
no.12
s.177
/
pp.205-210
/
2005
This paper addresses the correlation between the change of file size and the scanning path build time by the slicing height of STL file. Though the study about STL file has been achieved quite actively scanning path build time using STL file is not investigated so much to be satisfied. The file size depends on the number of polygon created by the slicing height specified. And this number of polygons increases in a regular rate. The correlation between the number of polygons and the scanning path build time is examined and verified.
Proceedings of the Korean Society of Precision Engineering Conference
/
2004.10a
/
pp.114-118
/
2004
This paper is compared the build time of scanning path as to laminate height of the SLC and STL file. The STL file improve the surface roughness according to slicing height. But it have the fault spending long time to the creation of scanning path by being lower slicing height. So we proposed the SLC file to improve this fault. Therefore this paper showed to the build time of scanning path by the increase of peace using the jewellery model.
Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect ($2.796{\pm}0.134$) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.
Journal of Dental Rehabilitation and Applied Science
/
v.28
no.3
/
pp.245-252
/
2012
The purpose of this study was to evaluate the influence of glide path on canal centering ratio after instrumentation with different single file systems; WaveOne and Reciproc. Reciproc R25 (VDW), WaveOne Primary (Dentsply Maillefer) and PathFile #13, 16, 19 (Dentsply Maillefer) were used in this study. In no glide path groups, Reciproc files and WaveOne files used for canal preparation without glide path. In glide path groups, the PathFile were used before canal preparation. Methylene blue dye was introduced into the canal to obtain a clear pre-instrumentation image. Pre-instrumentation images and post-instrumentation images were scanned using Epson Perfection V700 Photo scanner (Epson, Nagano, Japan). Transparencies of post-instrumentation images were changed and superimposed on pre-instrumentation images using Adobe Photoshop CS 3 (Adobe Systems Incorporated, San Jose, CA, USA). The centering ratio was calculated for each instrumented canal using the following formula: CR=|X1-X2|/Y. It was statistically analyzed using two-way ANOVA at 95% confidential level. The centering ratio in glide path groups were significant less than it in no glide path groups at 3, 4, 5 and 6 mm level. Except 1 and 6 mm level, WaveOne groups had significant less centering ration than Reciproc groups. At 6 mm level, there was no significant difference between WaveOne and Reciproc. In the limitation of this study, creation of a previous glide path before reciprocating motion instrumentation in curved canal appears to be appropriate and WaveOne system can be used for preparation of curved canal without severe aberrations.
Ha, Jung-Hong;Jeon, Hyo-Jin;Abed, Rashid El;Chang, Seok-Woo;Kim, Sung-Kyo;Kim, Hyeon-Cheol
Restorative Dentistry and Endodontics
/
v.40
no.2
/
pp.123-127
/
2015
Objectives: Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi) rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods: The G-file system (Micro-Mega) composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10). Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0) and 1 mm level (D1) under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05). Results: The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05). Conclusions: Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO) size 20, without apical transportation at D0 level.
Objectives: This preliminary study compared the effects of glide path establishing instruments prior to substantial root canal preparation. Materials and Methods: Glide path was established by enlargement of the 2nd mesiobuccal root canal of Dentalike by using three kinds of glide path preparation nickel-titanium file; PathFile, One G and ProGlider. The pre- and post-instrumented Dentalikes were weighed in the resolution of 1 / 10mg. In addition, after glide path preparation, torque generated during shaping using the WavoOne file was measured. The data were analyzed by one-way ANOVA and Tukey post-hoc test at a significance level of 95%. Results: The ProGlider had the significantly larger amount of reduced weight than other instrument groups (p < 0.05). There was no significant difference between group of glide path preparation with ProGlider and without glide path preparation in maximum torque and total stress generation during the shaping with WaveOne. Conclusions: Glide path preparation instruments may have different efficiency according to their geometries. The Dentalike artificial teeth were revealed to have discrepancies in the size of root canals by microCT examination. It is impossible to make a meaningful judgment of the results due to the reliability or resolution problem of the root canal size of the artificial tooth selected as the standardized tooth.
Objectives: The aim of this study was to investigate the effect of glide path preparation with PathFile and ProGlider nickel-titanium (NiTi) files on the cyclic fatigue resistance of WaveOne NiTi files. Materials and Methods: Forty-four WaveOne Primary files were used and divided into four groups (n = 11). In the first group (0 WaveOne), the WaveOne Primary files served as a control group and were not used on acrylic blocks. In the 1 WaveOne Group, acrylic blocks were prepared using only WaveOne Primary files, and in the PF+WaveOne group and PG+WaveOne groups, acrylic blocks were first prepared with PathFile or ProGlider NiTi files, respectively, followed by the use of WaveOne Primary files. All the WaveOne Primary files were then subjected to cyclic fatigue testing. The number of cycles to failure was calculated and the data were statistically analyzed using one-way analysis of variance (ANOVA) and the Tukey honest significant difference multiple-comparison test at a 5% significance level. Results: The highest number of cycles to failure was found in the control group, and the lowest numbers were found in the 1 WaveOne group and the PF+WaveOne group. Significant differences were found among the 1 WaveOne, PF+WaveOne, and control groups (p < 0.05). No statistically significant differences were found between the PG+WaveOne group and the other three groups (p > 0.05). Conclusion: Glide path preparation with NiTi rotary files did not affect the cyclic fatigue resistance of WaveOne Primary files used on acrylic blocks.
Ramyadharshini, Tamilkumaran;Sherwood, Inbaraj Anand;Vigneshwar, V Shanmugham;Prince, Prakasam Ernest;Vaanjay, Murugadoss
Restorative Dentistry and Endodontics
/
v.45
no.2
/
pp.22.1-22.10
/
2020
Objectives: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. Materials and Methods: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. Results: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. Conclusions: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15.
Park, Sang-Hee;Kim, Deok-Joong;Song, Yong-Beom;Lee, Hye-Yun;Kim, Hyoung-Sun;Lee, Kwang-Won;Yu, Mi-Kyung
Journal of Dental Rehabilitation and Applied Science
/
v.28
no.4
/
pp.371-383
/
2012
Shaping the root canal system to maintain original canal curvature is essential to clinical success in endodontic treatment. Opposed to most root canals that are curved, endodontic instruments are made from straight metal blanks. They have a tendency of straightening the root canal during preparation and frequently result in procedural errors. A new treatment method to maintain original canal curvature during shaping has been introduced for preventing procedural errors. The aim of this study was to compare the ability of instruments to maintain original canal curvature of continuous rotary system and single file system. Thirty ISO 15, 0.02 taper, Endo Training Blocks(Dentsplay Maillefer) were used. Specimens were assigned to 1 of 3 groups for shaping: specimens in group 1 were shaped with ProFile #20/.06 at the WL. Specimens in group 2 were shaped with Mtwo #35/.04 at the WL. Specimens in group 3 were shaped with WaveOne Primary reciprocating files at the WL after the glide path was achieved with PathFile. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b(The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio(CRr), representing canal curvature modification. Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file were analyzed with 1-way ANOVA(P<.05). Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file system were analyzed with independent t-test(P<.05). A statistically significant difference(P<0.05) was noted on each Ni-Ti file. ProFile and WaveOne instrumentations maintained the original canal curvature significantly better(P<0.05) than Mtwo file. There were no significant difference(P>0.05) between continuous rotary system and single file system. Under the conditions of this study, ProFile and WaveOne instruments maintained the original curvature significantly better than Mtwo file and were less modification of the canal curvature compared. There was no significant difference between continuous rotary system and single file system in shaping of simulated canals. As clinical practitioners, it may be advantages to use hybrid approach when root canal shapes depending on the design and usage of Ni-Ti files.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.