• Title/Summary/Keyword: Passive technique

Search Result 441, Processing Time 0.027 seconds

Design and experimental characterization of a novel passive magnetic levitating platform

  • Alcover-Sanchez, R.;Soria, J.M.;Perez-Aracil, J.;Pereira, E.;Diez-Jimenez, E.
    • Smart Structures and Systems
    • /
    • v.29 no.3
    • /
    • pp.499-512
    • /
    • 2022
  • This work proposes a novel contactless vibration damping and thermal isolation tripod platform based on Superconducting Magnetic Levitation (SML). This prototype is suitable for cryogenic environments, where classical passive, semi active and active vibration isolation techniques may present tribological problems due to the low temperatures and/or cannot guarantee an enough thermal isolation. The levitating platform consists of a Superconducting Magnetic Levitation (SML) with inherent passive static stabilization. In addition, the use of Operational Modal Analysis (OMA) technique is proposed to characterize the transmissibility function from the baseplate to the platform. The OMA is based on the Stochastic Subspace Identification (SSI) by using the Expectation Maximization (EM) algorithm. This paper contributes to the use of SSI-EM for SML applications by proposing a step-by-step experimental methodology to process the measured data, which are obtained with different unknown excitations: ambient excitation and impulse excitation. Thus, the performance of SSI-EM for SML applications can be improved, providing a good estimation of the natural frequency and damping ratio without any controlled excitation, which is the main obstacle to use an experimental modal analysis in cryogenic environments. The dynamic response of the 510 g levitating platform has been characterized by means of OMA in a cryogenic, 77 K, and high vacuum, 1E-5 mbar, environment. The measured vertical and radial stiffness are 9872.4 N/m and 21329 N/m, respectively, whilst the measured vertical and radial damping values are 0.5278 Nm/s and 0.8938 Nm/s. The first natural frequency in vertical direction has been identified to be 27.39 Hz, whilst a value of 40.26 Hz was identified for the radial direction. The determined damping values for both modes are 0.46% and 0.53%, respectively.

Ultra-small Form-Factor Helix on Pad-Type Stage-Bypass WCDMA Tx Power Amplifier Using a Chip-Stacking Technique and a Multilayer Substrate

  • Yoo, Chang-Hyun;Kim, Jung-Hyun
    • ETRI Journal
    • /
    • v.32 no.2
    • /
    • pp.327-329
    • /
    • 2010
  • A fully integrated small form-factor HBT power amplifier (PA) was developed for UMTS Tx applications. For practical use, the PA was implemented with a well configured bottom dimension, and a CMOS control IC was added to enable/disable the HBT PA. By using helix-on-pad integrated passive device output matching, a chip-stacking technique in the assembly of the CMOS IC, and embedding of the bulky inductive lines in a multilayer substrate, the module size was greatly reduced to 2 mm ${\times}$ 2.2 mm. A stage-bypass technique was used to enhance the efficiency of the PA. The PA showed a low idle current of about 20 mA and a PAE of about15% at an output power of 16 dBm, while showing good linearity over the entire operating power range.

Study of Soil Nailing Application as a Reinforcement Method for Slided Slope (붕괴사면보강을 위한 Soil Nailing의 적용성에 관한 연구)

  • 이성철;김명학
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.127-134
    • /
    • 2000
  • Soil nailing is in-situ ground improvement technique of reinforcing soils using passive inclusions for the purpose of slope stability. Also soil nailing, in general, was used and studied as a reinforcement technique at cut slope, but this paper presents the results of study for soil nailing application as a reinforcement technique at the banking over slided slope. In-situ pull-out tests of nails, instrumented with strain gauges, were performed to investigate the maximum pull-out load and to calculate the unit side resistance in each different layer. And the apparent average unit side resistance of this study was compared with that of other sites installed at cut slope.

  • PDF

Active Control of Sound in a Duct System by Back Propagation Algorithm (역전파 알고리즘에 의한 덕트내 소음의 능동제어)

  • Shin, Joon;Kim, Heung-Seob;Oh, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2265-2271
    • /
    • 1994
  • With the improvement of standard of living, requirement for comfortable and quiet environment has been increased and, therefore, there has been a many researches for active noise reduction to overcome the limit of passive control method. In this study, active noise control is performed in a duct system using intelligent control technique which needs not decide the coefficients of high order filter and the mathematical modeling of a system. Back propagation algorithm is applied as an intelligent control technique and control system is organized to exclude the error microphone and high speed operational device which are indispensable for conventional active noise control techniques. Furthermore, learning is performed by organizing acoustic feedback model, and the effect of the proposed control technique is verified via computer simulation and experiment of active noise control in a duct system.

A Review of Physical Therapies Approach for Cervicogenic Headache (경부인성 두통의 물리치료적 접근에 대한 문헌적 고찰)

  • Choi, Byung-Ok;Kim, Jong-Dae;Joo, Min-Jong
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.212-221
    • /
    • 2003
  • To observe the anatomical structures which cause a cervicogenic headache it reports, from viewpoint of physical therapist in treatment multiple to observe method which approaches, the reporter it does. With the manipulation the vertebral manipulation effected an affirmative effect to cervicogenic headache(Niels Nilsson et al,1997). The manipulation, soft the tissue massage, postural education/advice, muscular elongation, the traction, and postural exercises initially came to be used with that technique which the upper cervical vertebra(0-C3) passive accessory intervertebral movement comes to be used with a cervicogenic headache treatment technique(Grant T & Niere K., 2000). Also, it relates with the diagnosis standard about a cervicogenic headache when the body function over of the cervical vertebra is discovered, the Muscle energy technique was proposed in the treatment which is safety and effect(Bogduk N,2001). The TENS and the Mange gave a reduction effect of pain often.

  • PDF

A study on the advanced RFID system using the parallel cyclic redundancy check (병렬 순환 잉여 검사를 이용한 발전된 무선인식 시스템에 관한 연구)

  • Kang Tai-Kyu;Yoon Sang-Mun;Shin Seok-kyun;Kang Min-Soo;Lee Key-Sea
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1235-1240
    • /
    • 2004
  • This paper has presented the parallel cyclic redundancy check (CRC) technique that performs CRC computation in parallel superior to the conventional CRC technique that processes data bits serially. Also, it has showed that the implemented parallel CRC circuit had been successfully applied to the inductively coupled passive RFID system working at a frequency of 13.56MHz in order to process the detection of logical faults more fast and the system had been verified experimentally. In comparison with previous works, the proposed RFID system using the parallel CRC technique has been shown to reduce the latency and increase the data processing rates in the results. Therefore, it seems reasonable to conclude that the parallel CRC realization in the RFID system offers a means of maintaining the integrity of data in the high speed RFID system.

  • PDF

Seismic Response Fuzzy Control of Adjacent Building using Semi-active MR Dampers (준능동 MR 감쇠기를 이용한 인접빌딩의 지진응답 퍼지제어)

  • Ok, Seung-Yong;Kim, Dong-Seok;Park, Kwan-Soon;Koh, Hyun-Moo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.495-502
    • /
    • 2006
  • Seismic performance of semi-active fuzzy control algorithm to operate MR dampers for coupling adjacent building is investigated in this paper. In the proposed semi-active control technique, the fuzzy logic is used as a method to adjust input voltage to MR damper. In order to validate control performance of proposed technique, the seismic performance of the semi-active fuzzy control system is compared with that of passive control system where the input voltage to MR damper is set to display maximum damping force. The simulated results show that the semi-active fuzzy control technique effectively regulates the trade-off existing between seismic responses of two buildings subject to various earthquake excitations.

  • PDF

The efficacy of ultrasonic irrigation technique on debris removal during root canal treatment (근관치료 시 초음파 세정 기술을 이용한 잔사 제거의 효율성)

  • Kim, Jeong-Hyeon;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.97-105
    • /
    • 2017
  • Purpose: The purpose of this study was comparing the efficacy of passive irrigation (PI) and passive ultrasonic irrigation (PUI) for ability to remove debriment of canals. Materials and Methods: Mandibular premolars were decoronated and standardized to 16 mm length. After root canal enlargement and half separating longitudinally, standardized groove of 4 mm length, 0.2 mm width and 0.5 mm depth were formed on the dentin wall of one half. Three depressions in the canal wall of the opposite half, 0.3 mm in diameter and 0.5 mm in depth, were formed. After each groove and depression was filled with dentin debris, two sections of each half were reassembled using impression putty material. In group 1 the canals were irrigated with 2.5% NaOCl by PI. In group 2 the canals were irrigated with 2.5% NaOCl by PUI. Before and after root canal irrigation, the root canal wall of the section was taken with a microscope and a digital camera as images. The amount of dentin debris remaining in grooves and depressions was assessed using a scoring system. Results: There was no significant difference between PI and PUI except for the middle 1/3 of the root canal (P = 0.004). Conclusion: At the middle 1/3 of the root canal, PUI removed more dentine debris than PI. But the removal efficiency of dentin debris is not significantly different between the PUI and PI at the apical area of root canal in mandibular premolars.

Design and Simulation of Active Power Filter (전력 능동 필터의 설계 및 시뮬레이션)

  • 정동열;박종연;방선배
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2629-2632
    • /
    • 2003
  • This paper presents the harmonics rejection technique and the simulation of a active power filter using power operational amplifier. The proposed active power filter consists of CT(current transformer), harmonics detector and harmonics amplifier. The harmonics detector is a high pass filter using a GIC(Generalized Impedance Converter). The harmonics amplifier consists of a power operational amplifier and passive filters. The simulation has been implemented by OR-CAD program. It is examined whether the proposed active power filter can be realized or not through simple experiments.

  • PDF

Numerically Analytical Design of An Orifice Fluid Damper (오리피스 유체댐퍼의 수치해석적 설계)

  • 이재천;김성훈;문석준
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.105-112
    • /
    • 2003
  • This paper presents the numerical design technology of a passive orifice fluid damper system especially for the characteristics between the damper piston velocity and the damping force. Numerical analysis with the visual interfacial modeling technique was applied into the analysis of the damper system's dynamics. A prototype orifice fluid damper was manufactured and experimentally tested to validate the numerical simulation results. The performances of various damper system schemes were investigated based on the verified numerical simulation model of orifice fluid damper.