• Title/Summary/Keyword: Passive Type

Search Result 926, Processing Time 0.024 seconds

Franchise Contract Management Performance by Supervisor Type : A Case of 'Ganiyeok' (슈퍼바이저의 커뮤니케이션 유형에 따른 가맹점별 계약관리 성과 : 프랜차이즈 '간이역' 사례를 중심으로)

  • Park, Keumyoung;Park, Hyunsik;Park, Heena
    • The Korean Journal of Franchise Management
    • /
    • v.6 no.1
    • /
    • pp.42-68
    • /
    • 2015
  • As franchise industry has grown, the role of a supervisor who is a contact point between franchisor and franchisees has become more vital to success of the business. This research, focusing on his/her specific role, explores communication type, leadership type, and followership type of the supervisor in relations with the organization, franchisor, and franchisees, respectively. Furthermore, we compared performance of franchises by the three types above through the franchise contract management leverage (FCML) which reflects business performance both qualitatively and quantitatively. According to the analysis on supervisors of a franchise business, 'Ganiyeok', the majority of supervisors' communication type were either supportive style or directive style. For the leadership type, team-type and impoverished-type leaders were the majority, while effective or passive followership appeared highest in followership type. In addition, supportive supervisors in communication style, team-type supervisors in leadership style, and effective supervisors in followership had highest FCML, while reflective and directive styles, impoverished style, and passive style had lowest FCML. Primary goal of a franchise business is stable profit generation. This study not only examined what characteristics supervisors need and which style is insufficient, but also proposed tailored solutions for each style. Thus, we confirmed that debates on franchise can be approached in perspective of both communication and business, and we further suggest diverse approaches on future franchise business.

Effect of Gamiokyaek-tang on Immediate Type Hypersensitivity (가미옥액탕이 즉시형 과민반응에 미치는 영향)

  • Tsung, Pei-Yun;Kang, Kyung-Hwa;Kim, Won-Il
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.19 no.3 s.31
    • /
    • pp.13-21
    • /
    • 2006
  • Object : We investigated the effect of Gamiokyaek-tang (GOYT) on immediate type hypersensitivity. Methods : We investigated anti-dinitrophenyl (DNP) IgE-mediated passive cutaneous anaphylaxis and acetic acid-induced vascular permeability in rodents. Also perfonned MTT assay and b-hexosaminidase activity is measured in RBL-2H3. Results : GOYT inhibited passive cutaneous anaphylaxis and acetic acid-induced vascular permeability by oral administration. All the concentrations of GOYT from 0.1 to 5 mg/ml didn't have an effect on cell viability and cytotoxicity. b-hexosaminidase release in RBL-2H3 was significantly reduced by 2 and 5 mg/ml of GOYT. Conclusion : These results indicate that GOYT have inhibition effects on immediate type hypersensitivity .

  • PDF

Experimental Study for Thermal Performance of Batch Type Passive Solar Hot Water System (BATCH형 자연형 태양열 온수급탕 시스템의 열적 성능에 관한 실험적 연구)

  • Kang, Y.H.;Cho, Y.S.;Yoon, H.K.;Auh, P.Chung-Moo
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.3-13
    • /
    • 1987
  • A batch type passive solar water systems, which perform the dual function of absorbing the solar energy and storing the heated water, have been designed and fabricated for the purpose of side-by-side testing at KIER. The test models included an A, B and C type batch systems which were classified according to the design of box and arrangement of tanks. The year-round performance tests show that B type batch system taken the step-wise tank arrangement indicates 55.7% yearly-average collection efficiency factor and 61% yearly-average maximum collection efficiency factor. Computer-aided-experimental results show that the sufficient hot water can be obtained in the early morning if the glazing is supplemented by a reflector/insulation cover. The thermal performance equation has been developed for the prediction of hourly variation of the water temperature in tank.

  • PDF

Electrochemical Corrosion Characteristics of AISI-type 316 L Stainless Steel in Anode-Gas Environment of MCFC (용융탄산염 연료전지의 Anode가스 분위기에서 AISI-type 316L stainless steel의 전기화학적 부식 특성)

  • Lee, Kab-Soo;Lim, Tae-Hoon;Hong, Seong-Ahn;Kim, Hwa-Yong
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.2
    • /
    • pp.62-67
    • /
    • 2002
  • The corrosion of the metallic cell components is blown to be one of the major reason f3r the performance degradation and subsequently the life-time limitation of the MCFC. To elucidate the corrosion phenomena, a corrosion study with the AISI-type 316L stainless steel, the most widely used separator material, in 621Li/38K carbonate eutectic melt was carried out. Corrosion phenomena in an MCFC were observed to differ from one location to another due to different environmental condition. The stability of passive film was found to be responsible fur the variations in corrosion phenomena. According to the potentiodynamic analysis, the passive film formed in anode-gas environment was less stable than in cathode-gas environment. The potentiostatic method combined with XRD analysis in addition to the cyclicvoltammetry was conducted to get an insight on variety corrosion reaction of AISI-type 316L stainless steel in a carbonate melt.

연구개발 전문가 유형에 따른 인적자원관리

  • 김영배;차종석
    • Proceedings of the Technology Innovation Conference
    • /
    • 1997.07a
    • /
    • pp.57-82
    • /
    • 1997
  • This paper empirically examines various personal characteristics and preferences of HRM (Human Resorce Mamagement) systems using data from 968 R&D professionals in 9 private R&D organizations. It identifies different patterns of reward and career development needs associated with 4 types of R&D professionals, who are categorized by personal characteristics: personality and attitude. A productive leader type shows active personal traits (which encompass high scores of need for achievement, risk-taking propensity, tolerance for ambiguity, and self-efficacy) and positive attitudes (which include high scores of job satisfaction, organizational commitment, and low scores of turnover intention), while a cynical bystander type exhibits passive personal traits and negative attitudes toward a job. A passive adapter, who has passive personal characteristics but positive attitudes, and a frustrated champion, who is active in personality but negative in current job attitude, lie in between them. The results reveal that: 1) These four different types of R&D professionals show differences in their education, age and tenure level, and technical performance. 2) They have different career orientations and problem solving styles. 3) They also exhibit different preferences in performance appraisal criteria and rater, and reward structures. Based on these findings, this study suggests a contingent type of human resource management in terms of selection and staffing of R&D professionals, performance appraisal, incentive systems, and career development plans.

  • PDF

Development of Passive-Type Radar Reflector for Fisheries

  • Kim, Woo-Suk;Yim, Jeong-Bin;Ahn, Yoeng-Sub;Park, Sung-Hyeon;Jung, Jung-Sik;Lee, Kyu-Dong
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2003.05a
    • /
    • pp.135-139
    • /
    • 2003
  • This paper describes on the development of Passive-type Radar Reflector for Fisheries (PRR-F) based on the newly revised 2000 SOLAS regulations. The purpose of PRR-F is to provide it as the protection devices of a fishing net and a fishing field. The PRR-F is composed of corner cluster bundle of light galvanized iron, and it is inserted into floating styrofoam. Performance tests for the PRR-F are carried out in an anechoic chamber. The test results show that the reflected radar signal from PRR-F is large enough for the purpose.

  • PDF

Wheelset Steering Control for Improvement a Running Safety on Curved Track (곡선부 주행안전성 향상을 위한 윤축 조향 제어)

  • Hur, Hyun Moo;Ahn, Da Hoon;Kim, Nam Po;Sim, Kyung Seok;Park, Tae Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.759-764
    • /
    • 2014
  • Lateral force of wheel is important parameter when we evaluate the safety of a railway vehicle on curved track. The lateral force of wheel is influenced by the steering performance of wheelsets. Generally, in passive type vehicles, the steering performance of wheelsets is influenced by the parameters like primary spring stiffness, wheel base, conicity of the wheel profile, etc. But, the steering performance of passive type vehicle has its limit. To overcome the limit of the steering performance of passive type vehicle, active steering technology is being developed. In this paper, we analyze the lateral force of wheel and the safety of the railway vehicle on curved track by adopting the active steering technology. As results of dynamic analysis for vehicle model equipped with active steering system, the lateral force of wheel is reduced and the safety is improved remarkably.

Application of a C-Type Filter Based LCFL Output Filter to Shunt Active Power Filters

  • Liu, Cong;Dai, Ke;Duan, Kewei;Kang, Yong
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.1058-1069
    • /
    • 2013
  • This paper proposes and designs a new output filter called an LCFL filter for application to three phase three wire shunt active power filters (SAPF). This LCFL filter is derived from a traditional LCL filter by replacing its capacitor with a C-type filter, and then constructing an L-C-type Filter-L (LCFL) topology. The LCFL filter can provide better switching ripple attenuation capability than traditional passive damped LCL filters. The LC branch series resonant frequency of the LCFL filter is set at the switching frequency, which can bypass most of the switching harmonic current generated by a SAPF converter. As a result, the power losses in the damping resistor of the LCFL filter can be reduced when compared to traditional passive damped LCL filters. The principle and parameter design of the LCFL filter are presented in this paper, as well as a comparison to traditional passive damped LCL filters. Simulation and experimental results are presented to validate the theoretical analyses and effectiveness of the LCFL filter.

Characteristic Analysis of Flyback Type ZVS PWM DC-DC Converter Using Passive Resonant Snubber (패시브 공진 스너버를 이용한 플라이백형 ZVS PWM DC-DC 컨버터의 특성해석)

  • Kim, Jung-Do;Mun, Sang-Pil;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.158-164
    • /
    • 2016
  • In this paper, a high frequency flyback type zero voltage soft switching PWM DC-DC converter using IGBTs is proposed. Effective applications for this power converter can be found in auxiliary power supplies of rolling stock transportation and electric vehicles. This power converter is basically composed of active power switches and a flyback high frequency transformer. In addition to these, passive lossless snubbers with power regeneration loops for energy recovery, consisting of a three winding auxiliary high frequency transformer, auxiliary capacitors and diodes are introduced to achieve zero voltage soft switching from light to full load conditions. Furthermore, this power converter has some advantages such as low cost circuit configuration, simple control scheme and high efficiency. Its operating principle is described and to determine circuit parameters, some practical design considerations are discussed. The effectiveness of the proposed power converter is evaluated and compared with the hard switching PWM DC-DC converter from an experimental point of view and the comparative electromagnetic conduction and radiation noise characteristics of both DC-DC power converter circuits are also depicted.

Parametric analyses for the design of a closed-loop passive containment cooling system

  • Bang, Jungjin;Hwang, Ji-Hwan;Kim, Han Gon;Jerng, Dong-Wook
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1134-1145
    • /
    • 2021
  • A design parameter study is presented for the closed-loop type passive containment cooling system (PCCS) which is equipped with two heat exchangers: one installed at the inside of the containment and the other submerged in the water pool at the outside of the containment. A GOTHIC code model for PCCS performance analyses was set up and the design parameters such as the heat exchanger sizes, locations, and water pool tank volumes were analyzed to investigate the feasibility of installing this type of PCCS in PWRs like OPR-1000 being operated in Korea. We identified the size of the circulation loop and heat exchangers as major design parameters affecting the performance of PCCS. The analyses showed that the heat exchangers in the inside of the containment would be more influential on the heat removal capability of PCCS than that installed in the water pool at the outside of the containment. Hence, it was recommended to down-size the heat exchangers in the water pool to optimize PCCS without compromising its performance. Based on the parametric study, it was demonstrated that a closed-loop type PCCS could be designed sufficiently compact for installation in the available space within the containment of PWRs like OPR-1000.