Diagnostic Technique for Cast Resin Molded Transformer Windings Using Active Thermography

  • Lim Young-Bae;Jung Jong-Wook;Jung Jin-Soo;Cho Seong-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.376-380
    • /
    • 2006
  • Temperature distribution measured to estimate the condition of an electrical apparatus is an absolute reference for the apparatus conditions and the difference between the reference temperature and the current temperature. Because of passive thermography, without the external thermal stimulation, the difference in surface temperature between the region of interest and back ground shows that the results can apply only to the estimation or the monitoring for the condition of loose terminal and the overload pertaining to the rise in temperature. However, a thermal diffusion in the active thermography is differently generated by the structure and condition of the surface and subsurface. This paper presents a nondestructive test using this behavior and deals with the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

LEGACY OF THE SPICA CORONAGRAPH INSTRUMENT (SCI): TOWARD EXOPLANETARY SCIENCE WITH SPACE INFRARED TELESCOPES IN THE FUTURE

  • Enya, Keigo
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.347-349
    • /
    • 2017
  • This paper reviews the legacy of the SPCIA Coronagraph Instrument (SCI) of which the primary scientific objective is the characterization of Jovian exoplanets by coronagraphic spectroscopy in the infrared. Studies on binary shaped pupil mask coronagraphs are described. Cryogenic active optics is discussed as another key technology. Then approaches to observing habitable zones in exoplanetary systems with a passively-cooled space infrared telescope are discussed. The SCI was dropped in a drastic change of the SPICA mission. However, its legacy is useful for space-borne infrared telescopes dedicated for use in exoplanetary science in the future, especially for studies of biomarkers.

Feasibility Study of the Decay Heat Removal Capability Using the Concept of a Thermosyphon in the Liquid Metal Reactor

  • Kim, Yeon-Sik;Sim, Yoon-Sub;Kim, Eui-Kwang
    • 에너지공학
    • /
    • 제10권4호
    • /
    • pp.342-348
    • /
    • 2001
  • A new design concept for a decay heat removal system in a liquid metal reactor is proposed. The new design utilizes a thermosyphon to enhance the heat removal capacity and its heat transfer characteristics are analyzed against the current PSDRS (Passive Safety Decay heat Removal System) in the KAL IMER (Korea Advanced LIquid MEtal Reactor) design. The preliminary analysis results show that the new design with a thermosyphon yields substantial increase of 20∼40% in the decay heat removal capacity compared to the current design that do not have the thermosyphon. The new design reduces the temperature rise in the cooling air of the system and helps the surrounding structure in maintaining its mechanical integrity for long term operation at an accident. Also the analysis revealed the characteristics of the interactions among various heat transfer modes in the new design.

  • PDF

MULTI-SCALE THERMAL-HYDRAULIC ANALYSIS OF PWRS USING THE CUPID CODE

  • Yoon, Han Young;Cho, Hyoung Kyu;Lee, Jae Ryong;Park, Ik Kyu;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • 제44권8호
    • /
    • pp.831-846
    • /
    • 2012
  • KAERI has developed a two-phase CFD code, CUPID, for a refined calculation of transient two-phase flows related to nuclear reactor thermal hydraulics, and its numerical models have been verified in previous studies. In this paper, the CUPID code is validated against experiments on the downcomer boiling and moderator flow in a Calandria vessel. Physical models relevant to the validation are discussed. Thereafter, multi-scale thermal hydraulic analyses using the CUPID code are introduced. At first, a component-scale calculation for the passive condensate cooling tank (PCCT) of the PASCAL experiment is linked to the CFD-scale calculation for local boiling heat transfer outside the heat exchanger tube. Next, the Rossendorf coolant mixing (ROCOM) test is analyzed by using the CUPID code, which is implicitly coupled with a system-scale code, MARS.

시멘트 종류별 무기단열재용 경량 경화체의 특성 (Properties of lightweight matrix for inorganic insulation by cement types)

  • 임정준;편수정;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.222-223
    • /
    • 2018
  • Recent government policies are increasing interest in zero-energy housing, a building that minimizes energy consumption (90% reduction). As the importance of building passive performance is emphasized, the role of insulation is increasing as a way to reduce indoor heat loss in order to minimize the use of cooling and heating energy. There are two main types of insulation. Organic insulation is widely used for various construction structures such as construction and industrial due to some merits such as the convenience of construction and construction cost. However, it has been pointed out as a main cause every time a fire accident occurs, Jecheon Sports Center', the fire damage of buildings caused by the use of organic insulation materials is expanding to social problems, so it is urgent to research on nonflammable inorganic insulation materials.

  • PDF

제로 에너지 하우스 구축을 통한 설계, 시공, 유지관리 최적 방안에 관한 연구 및 제안 (The Study Of Optimum Method About The Architecture, Construction, And Maintenance Through The Construction Of Zero Energy House)

  • 김선근;권순욱
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.42-50
    • /
    • 2014
  • In the thesis, the case of zero energy house construction applied with various Active factors and Passive factors which is the real residence as a standard not a normal experimental residence was evaluated, analyzed, and organized. The thesis can be the base data to construct another similar case of zero energy house.

기축건물의 제로에너지 하우스 하자 사례를 통한 공종별 문제점 및 최적구축 방안에 관한 연구 (The Study on Activity Star Problem and Optimum Construction Method Through the Defect Case of Zero Energy House in the Existing Building)

  • 김선근;권순욱
    • 한국전기전자재료학회논문지
    • /
    • 제28권4호
    • /
    • pp.262-270
    • /
    • 2015
  • In this paper existing buildings, not a new buildings and house for living people not just a displaying and a viewing, created by the imagine effect or virtual simulation was applied various Active and Passive elements. After constructing zero-energy houses, through default case happened during operation period it is described problems and solutions about field part, work classification, installation by Location part, and Installation equipment part. Since then, to take advantage of this thesis, it's the purpose of this paper using as the baseline data for building a zero-energy house in another similar case.

Multitasking Façade: How to Combine BIPV with Passive Solar Mitigation Strategies in a High-Rise Curtain Wall System

  • Betancur, Juan
    • 국제초고층학회논문집
    • /
    • 제6권4호
    • /
    • pp.307-313
    • /
    • 2017
  • This paper outlines the processes and strategies studied and selected by the team during the design stages of the project for the incorporation of BIPV into the tower's façade. The goal was to create a system that helps reduce internal heating and cooling loads while collecting energy through photovoltaic panels located throughout the building. The process used to develop this façade system can be broken down into three stages. 1. Concept: BIPV as design catalyst for a high-rise building. 2. Optimization: Balancing BIPV and Human comfort. 3. Integration: Incorporating BIPV into a custom curtain wall design. The FKI Project clearly illustrates the evolution building enclosures from simple wall systems to high performance integrated architectural and engineering design solutions. This design process and execution of this project represent the design philosophy of our firm.

열화상을 이용한 몰드변압기 권선표면 진단 (Diagnostic Technique for Mold Transformer Windings using Thermal Image)

  • 임용배;정종욱;정진수;고원식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.107-109
    • /
    • 2005
  • Temperature distribution measured to estimate condition of an electrical apparatus is an absolute reference for the apparatus conditions and the difference between the reference temperature and the current one. Because a passive thermography without the external thermal stimulation shows the difference in surface temperature between the object and back ground, the results can apply only to the estimation or the monitoring for the condition of terminal loose and the overload pertaining to the rise in temperature. However, a thermal flow in the active thermography is differently generated by the structure and condition of the surface and subsurface. This paper presents the nondestructive testing using the behavior and deals with the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

  • PDF

능동열시험법을 이용한 몰드변압기 진단 (Diagnostic of Cast Resin Using Active Infrared Thermal Testing Method)

  • 임용배;정승천
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.481-484
    • /
    • 2004
  • A form of measured temperature distribution to estimate condition of a electrical apparatus is a absolute reference for condition of the apparatus, time rate of transition, and difference between reference and currently temperature. Because passive thermography which has not injection of external thermal stimulation shows difference of temperature being on surface of a structure and temperature difference between the structure and back ground, the result could apply only to estimation or monitor for condition of terminal relaxation and overload related with temperature rising. However, a thermal flow in active thermography is differently generated by structure and condition of surface and subsurface. This paper presents the nondestructive testing using the properties and includes the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

  • PDF