• Title/Summary/Keyword: Passive Component

Search Result 200, Processing Time 0.025 seconds

A Study on Basic Characteristics of Short Wavelength Transmission Line Employing Periodically Arrayed Capacitive Devices and Its Application to Highly Miniaturized Passive Components on MMIC (주기적으로 배치된 용량성 소자를 이용한 단파장 전송선로의 기본특성 연구와 MMIC용 초소형 수동소자개발에의 응용)

  • Jang, Eui-Hoon;Jeong, Jang-Hyeon;Choi, Tae-Il;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.157-165
    • /
    • 2012
  • In this study, a short-wavelength transmission line employing periodically arrayed capacitive devices (PACD) was studied for application to miniaturized on-chip passive component on monolithic microwave integrated circuit (MMIC). The transmission line employing PACD showed shorter wavelength and lower characteristic impedance than conventional microstrip transmission line. The wavelength transmission line employing PACD structure was 8% of the conventional microstrip transmission line on GaAs substrate. Using the theoretical analysis, basic characteristic of the transmission line employing PACD (e.g., loss, effective dielectric constant, effective propagation constant, bandwidth ) were also investigated in order to evaluate its suitability for application to a development of miniaturized passive on-chip components on MMIC. Above results indicate that the transmission line employing PACD is a promising candidate for a development of miniaturized passive components on MMIC.

Occurrence and distribution of indoor volatile organic compounds in residential spaces by sampling methods (시료채취 방식에 따른 주거 공간 내 휘발성유기화합물 발생 특성 평가)

  • Lee, Suyeon;Kim, Daekeun
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.362-371
    • /
    • 2018
  • Indoor Volatile organic compounds (VOCs) are classified as known or possible toxicants and odorants. This study characterized VOC levels in 11 homes in an area in the capital of Seoul by using two different methods of VOCs sampling, which are the active sampling using a thermal sorption tube and the passive sampling using a diffusion sampler. When using the active sampling method, the total target VOC concentration ranged from 41.7 to $420.7{\mu}g/m^3$ (mean $230.4{\mu}g/m^3$ ; median $221.8{\mu}g/m^3$) during winter and 21.3 to $1,431.9{\mu}g/m^3$ (mean $340.1{\mu}g/m^3$; median $175.4{\mu}g/m^3$) during summer. When using the passive method, 29.6 to $257.5{\mu}g/m^3$ (mean $81.8{\mu}g/m^3$; median $49.4{\mu}g/m^3$) during winter and 1.2 to $5,131.1{\mu}g/m^3$ (mean $1,758.8{\mu}g/m^3$; median $1,375.1{\mu}g/m^3$) during summer. Forty-nine VOCs were quantified and toluene showed the highest concentration regardless of the season and the sampling method studied. The distribution of VOCs was relatively varied by using the active method. However, it showed a low correlation with indoor environmental factors such as room temperature, humidity and ventilation time. The correlation between indoor environmental factors and VOCs were relatively high in the passive method. In particular, these characteristics were confirmed by principal component analysis.

A Study on Effect of Pad Design on Assembly and Adhesion Reliability of Surface Mount Technology (SMT) (표면실장기술(SMT)의 조립 및 접합 신뢰성에 대한 패드설계의 영향에 관한 연구)

  • Park, Dong-Woon;Yu, Myeong-Hyeon;Kim, Hak-sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.3
    • /
    • pp.31-35
    • /
    • 2022
  • Recently, with the 4th industrial revolution, the demand for high-density semiconductors for large-capacity data processing is increasing. Researchers are interested in researching the reliability of surface mount technology (SMT). In this study, the effect of PCB pad design on assembly and adhesion reliability of passive component was analyzed using design of experiment (DOE). The DOE method was established using the pad length, width, and distance between pads of the PCB as variables. The assembly defect rate of the passive element after the reflow process was derived according to the misplacement direction of the chip resistor. The shear force between the passive element and the PCB was measured using shear tests. In addition, the shape of the solder according to the pad design was analyzed through cross-sectional analysis.

A study of real-time holographic display based on volume hologram (체적 홀로그램을 이용한 실시간 홀로그래픽 디스플레이 연구)

  • 강훈종;안충현;이승현
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.203-206
    • /
    • 2003
  • This study is focused on proposing a creative system that can display 3D hologram on the real-time basis. This method applies 3D display on volume hologram based on CGH. The process of implementing the system consists of two stages of fringe pattern recording for passive component that includes information on hologram, and irradiating object beam. Distinguished from an existing electronic holographic display system, this system is free from the process of a huge calculation that is necessary to compose CGH for a real-time 3D display.

  • PDF

Insulation Performance Analysis of Exposed Concrete Sandwich Wall (노출콘크리트 중단열 벽체의 단열성능 분석)

  • Yeo, Chang-Jae;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.105-106
    • /
    • 2016
  • The study of the sandwich wall with the increasing interest in building energy consumption have been actively conducted. This study designed exposed sandwich wall in the light of energy saving design standard and thermal bridge of share connection. The heat insulating performance was analyzed U-fator using calculation program provided in passive houses association and KS F 2277 (method of measuring thermal insulation of construction component materials).

  • PDF

Statistical Modeling of 3-D Parallel-Plate Embedded Capacitors Using Monte Carlo Simulation

  • Yun, Il-Gu;Poddar, Ravi;Carastro, Lawrence;Brooke, Martin;May, Gary S.
    • ETRI Journal
    • /
    • v.23 no.1
    • /
    • pp.23-32
    • /
    • 2001
  • Examination of the statistical variation of integrated passive components is crucial for designing and characterizing the performance of multichip module (MCM) substrates. In this paper, the statistical analysis of parallel plate capacitors with gridded plates manufactured in a multilayer low temperature cofired ceramic (LTCC) process is presented. A set of integrated capacitor structures is fabricated, and their scattering parameters are measured for a range of frequencies from 50 MHz to 5 GHz. Using optimized equivalent circuits obtained from HSPICE, mean and absolute deviation is calculated for each component of each device model. Monte Carlo Analysis for the capacitor structures is then performed using HSPICE. Using a comparison of the Monte Carlo results and measured data, it is determined that even a small number of sample structures, the statistical variation of the component values provides an accurate representation of the overall capacitor performance.

  • PDF

Compensation of Source Voltage Unbalance and Current Harmonics in Series Active and Shunt Passive Power Filters

  • Lee G-Myoung;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.586-590
    • /
    • 2001
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for hybrid active power filters is proposed, where no low/high-pass filters are used in compensation voltage composition. The phase angle and compensation voltages for source harmonic current and unbalanced voltage components are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. Since a balanced set of the source voltage obtained by scaling the positive sequence components is used as reference values for source current and load voltage, it is possible to eliminate the necessity of low/high-pass filters in the reference generation. Therefore the control algorithm is much simpler and gives more stable performance than the conventional method. In addition, the source harmonic current is eliminated by compensating for the harmonic voltage of the load side added to feedback control of the fundamental component.

  • PDF

A Study on the Characteristic of Capacitor by Asymmetrical Voltage Unbalance (비대칭 전압 불평형에 의한 커패시터 동작 특성)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • As the increasing of Non-linear load, we have been growing interest for the harmonics. Harmonics has been focused on the current component rather than voltages. Voltage harmonics can be mainly generated at the PCC with non-linear load and act on voltage unbalance. Voltage harmonics can be enlarged at the capacitor with low impedance as frequency increases. Capacitor is basically used for the power-factor compensation and sometimes as the passive filter. Small voltage of low-order acts on quite a few at the capacitor by the current increase. Capacitor has easily fall under by harmonic components. In this paper, we measured the magnitude and phase angle of asymmetrical voltage with harmonics components at the PCC and calculated with the same condition. we concluded that voltage harmonics of higher order increase each current component but have a little effect on capacitor rating.

Fall arresting system

  • Leamon, T.S.;Malone, C.;Son, D.H.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.23-28
    • /
    • 1991
  • A major inhibition of past work in a slip/fall accident study has been due to the lack of a facility and a methodology to experimentally investigate such behavior without expowting human subjects to the natural danger of injury resulting from a fall. In order to carry out a slip/fall research, a unique facility must be created specially to investigate falling and slipping behavior. One component of this facility will be used to focus a research towards experimental investigations of the basic mechanisms involved in falls. Especially, this compo- nent must be designed, developed, and fabricated to provide passive, reactive support at the point of loss of ba- lance. This component must allow both normal and reduced friction surfaces to be designated to investigate human falling in the experimental conditions. This study will address how a fall arresting system was designed and it would be implemented in actual case of a slip/fall study.

  • PDF

Analysis for Electrical Stress of Power Capacitor (전력용 커패시터의 전기적 스트레스 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong;Lee, Dong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.370-376
    • /
    • 2008
  • Power capacitors is widely used for power factor correction and component of passive filter in the user power systems. Recently, application of non-linear load is gradually increased. Non-linear load produces harmonic components of current. There are series resonance and parallel resonance when capacitors are applied in the user electrical application. If this harmonic component matches resonance, voltage and current is magnified and has severely an influences on capacitor. This paper purposes a new method for the magnitude of voltage and current by the frequency scan analysis without equivalent circuit for the actual circuit at the resonance condition.