• Title/Summary/Keyword: Passive

Search Result 7,189, Processing Time 0.04 seconds

A Study on the POE-based Energy Utilization Satisfaction Analysis for Passive House in Germany

  • Chung, Hae Jo;Kim, Sooyong;Yang, Jinkook
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.17-23
    • /
    • 2016
  • Passive House represents energy-saving technologies. It aims to save energy and provide comfort to the dwellers. The design and construction began in Germany, where it is commonly observed. In South Korea, implementation of the Passive House concept is difficult because of high construction costs and technological problems. This study performed a POE analysis to analyze the extents of satisfaction and knowledge about Passive House among those who live in them in Germany. The results found high satisfaction with functional aspects, such as ventilation, windows, doors, and the thermal bridge. These research results will provide application criteria for Passive House construction in South Korea.

Vibration Control of Beams Using Mechanical-Electrical Hybrid Passive Damping System (전기적-기계적 수동감쇠기를 이용한 빔의 진동제어)

  • 안상준;박현철;박철휴
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.362-367
    • /
    • 2003
  • A new mechanical-electrical hybrid passive dam ping treatment is proposed to improve the performance of structural vibration control. The proposed hybrid passive damping system consists of a constrained layer damping treatment and a shunt circuit. In a passive mechanical constrained layer damping, a viscoelastic material damping layer is used to control the structural vibration modes in high frequency range. The passive electrical damping is designed for targeting the vibration amplitude in the low frequency range. The governing equations of motion are derived through the Hamilton's principle. The obtained mathematical model is validated experimentally. The presented theoretical and experimental techniques provide invaluable tools for controlling the multiple modes of a vibrating structure over a wide frequency band.

  • PDF

A Passive Multiple Trailer System with Off-axle Hitching

  • Lee, Jae-Hyoung;Woojin Chung;Kim, Munsnng;Song, Jae-Bok
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.3
    • /
    • pp.289-297
    • /
    • 2004
  • This paper deals with the design and control of passive multiple trailer systems for practical applications. Due to the cost and complexity of the trailer mechanism, passive systems are preferred to active systems in this research. The design and control objective is to minimize the trajectory tracking errors occurring in passive multiple trailers. Three sorts of passive trailer systems, off-hooked, direct-hooked, and three-point, are discussed in this paper. Trajectory tracking performance and stability issues under constant curvature reference trajectories are investigated for these three types. As well, various simulations and experiments have been performed for each type. It is shown that the proposed off-hooked trailer system produces a tracking performance that is superior to the others.

Harm of Passive Smoking (간접 흡연의 유해성)

  • Lee, Dong-Uk
    • Journal of Korea Association of Health Promotion
    • /
    • v.3 no.2
    • /
    • pp.165-171
    • /
    • 2005
  • Passive smoking is the involuntary inhalation of tobacco smoke by a person, especially a non-smoker, who occupies and area with smokers or a smoker. Passive smoking may cause eye and nose irritation, sore throat, headache, cough to everyone, and it is known that non-smokers have the same kinds of illness with smokers. Smoking rate among the adults aged over 20 in Korea is higher than that of the US or European conturies. Therefore we suppose that Koreans may be exposured to passive smoking than the people of other conturies. It is necessary that people have the knowledge on the heath problems caused by passive smoking and on prevention from the involuntary inhalation of tobacco smoke. I propose that the smokers should be informed the importance of smoking cessation.

  • PDF

A Study on Characteristics of De-electrification and Discharge of Self-Discharged Electrostatic Reducer (자기방전식제건기에 의한 대전물체의 제전 및 방전특성)

  • 박수덕;이동훈
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.2
    • /
    • pp.72-76
    • /
    • 1995
  • An electrostatic passive neutralizer without HV power source has been used widely to reduce charges on insulators such as running plastic films, papers and cloths, but its elimination characteristics and safely have been hardly investigated in detail. Especially, an operation of the passive neutralizer depends primarily on the charged insulator and the elimination ability does not depend on only the neutralizer, because an electrostatic elimination is caused by corona discharges occurring between the passive neutralizer and charged insulator. From a reason described above, the purpose of this study is to examine experimentally the elimination ability of the passive neutralizer. Experiments were made on the corona discharges between the passive neutralizer and charged insulator running at high velocity in practical field to make clear the setting condition of the passive neutralizer for operating effectively and safely. Results obtained from field experiments are presented in this paper.

  • PDF

A Study on the Monitoring System of Passive Filter to Improve Power Quality (전력품질 개선을 위한 수동필터 모니터 시스템에 관한 연구)

  • Yu, Jae-Geun;Lee, Sang-Ik;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.89-91
    • /
    • 2007
  • In this paper, we developed DSP based control system to automatically open and close passive filter, which is used to reduce harmonics, according to operating condition of loads. Passive filter control system automatically open and close each branch of filter according to working conditions of loads by sending signals to open and close installation of passive filter after measuring and monitoring voltage, current, harmonics, reactive power, power factor and so on. We verified it's performance by connecting control system with passive filter in the power line using the 100[HP] d.c. motor drive, opening and closing passive filter according to operation condition of motor, and measuring harmonics and reactive power, etc.

  • PDF

Research on the Urban Ecological Space Changes under Modern Passive Industrialization Case Study of Zhengzhou City in China

  • Yang, Juntao;Baek, Seungman
    • Architectural research
    • /
    • v.23 no.2
    • /
    • pp.29-37
    • /
    • 2021
  • Early in the communist era, many cities in modern China experienced a special period of passive industrialization during which the construction of urban spaces laid the spatial urban foundation. During this period, the city construction was carried out rapidly under the administrative intervention of the government. The passive industrialization caused by taking economic construction as the center made the city construction deviate from the correct track and resulted in a variety of problems. Focusing on ecological space change, this paper selects Zhengzhou as an example of many similar cities in China, and analyzes the impact of passive industrialization on urban ecological spaces from the perspectives of city scale, city layout and city construction management system. The analysis results reveal that the construction of urban ecological space under the influence of passive industrialization induced a lagging characteristic, led to insufficient integrity of urban ecological space, and placed great pressure on the urban environment. Finally, the paper puts forward some methods to optimize the urban ecological space.

Design and Application of Harmonic Passive Filter (고조파 수동필터의 설계 및 적용)

  • Jeon, Jeong-Chay;Kim, Jae-Hyun;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5397-5402
    • /
    • 2012
  • Accidents involving electric equipment and economical loss by power quality deterioration related to harmonics show a rising tendency A passive filter is economic and efficient in suppressing harmonics but many engineers and designers are reluctant to install a passive filter to defect harmonics at their power system because of problems such as harmonic amplification and the probability of generating series or parallel resonance with the power system. This work introduces that passive filters will be very available to defeat harmonic problems of the power system if passive filters are well designed. We describe method and process of harmonic passive filter design. And the passive filter for the power system having harmonic problems due to use of nonlinear loads like as 100HP DC motor system, an extruding machine, an air blower and other loads are designed. Experimental results verify the performance of the passive filter designed by the described method and procedure.

Passive Force Acting on the Kicker Block Used to Support a Raker in Soft and Weathered Soil (연약지반과 풍화토지반에서 경사고임대 지지블록의 수동토압 산정)

  • Kim, Tae Hyung;Park, Lee Keun;Kim, Tae O;Jin, Hyun Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.801-813
    • /
    • 2017
  • Passive force acting on the kicker block used to support a raker is different dependent on soil's type. The passive force incorporating a factor of safety is considered for design of the retaining wall. However, an actual passive force developing on the kicker block is overestimated and it may lead to an unsafe design. In this study, the actual passive forces acting on the kicker block in soil ground are evaluated using 3-D Finite Element Program, PLAXIS. Soft and weathered soils are selected as a soil ground. The relation curves between horizontal displacement and actual passive force of the kicker block for each soil ground are obtained through numerical analyses. From the curves, the actual passive forces are determined as a yielding point, which are about 55.5% and 66% of Rankine's passive forces in soft and weathered soils, respectively.

Effect of Subtalar Joint Neutral Position and Knee Position on the Passive Ankle Dorsiflexion Range of Motion (목말밑 관절의 중립자세와 무릎관절 자세가 수동적인 발등굽힘 가동범위에 미치는 영향)

  • Jung, Do-young
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.23-31
    • /
    • 2019
  • Background: Measurement of passive ankle dorsiflexion range of motion (ADROM) is often part of a physical therapy assessment. Objects: The objective of this study was to identify the effects of subtalar joint neutral position (SJNP) on passive ADROM according to knee position in young adults. Methods: We recruited 14 young adult participants for this study. Two examiners used a universal goniometer to measure passive ADROM with and without SJNP. Dorsiflexion force was applied to the forefoot until maximum resistance was reached in two knee positions (extension and $90^{\circ}$ flexion) in the prone position. Subtalar joint position was also recorded at maximum ADROM. Passive ADROM was measured three times at different knee and subtalar joint positions, in random order. Two-way repeated-measures analysis of variance was used to compare the effects of subtalar joint and knee position on passive ADROM. Results: Passive ADROM was significantly lower with than without SJNP during both knee extension (mean difference: $7.4^{\circ}$) and $90^{\circ}$ flexion (mean difference: $16.9^{\circ}$) (p<.01). Passive ADROM was significantly higher during $90^{\circ}$ knee flexion than during knee extension both with (mean difference: $5.8^{\circ}$) and without SJNP (mean difference: $15.2^{\circ}$) (p<.01). The valgus position of the subtalar joint was significantly lower with than without SJNP during both knee extension (mean difference: $3.3^{\circ}$) and $90^{\circ}$ flexion (mean difference: $4.3^{\circ}$) (p<.01). Conclusion: Our results indicate that the gastrocnemius may limit ankle dorsiflexion more than the soleus does. Greater dorsiflexion at the subtalar and midtarsal joints was observed during passive ADROM measurement without than that with SJNP; therefore, SJNP should be maintained for accurate measurement of ADROM.