• 제목/요약/키워드: Passed tests

검색결과 148건 처리시간 0.032초

인상채득 후 시간경과와 반복주입에 따른 부가중합형 실리콘 인상재의 체적변화 (Evaluation of the Time and Pouring Frequency Dependent Dimensional Stability of Additional Silicone Impression Materials.)

  • 최미라
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.239-248
    • /
    • 2007
  • The accuracy and dimensional stability of rubber impression materials are very important for the fitness of the final restoration. The purpose of this investigation was to evaluate the effects of the storage time and pouring frequency of the additional silicone materials on dimensional stability. Total 30 impressions were made of tooth prepared single crown. The dies had 1 buccolingual, 1 mesiodistal and 1 occlusogingival lines. Two additional silicone materials(examixfine, aquasil) were included. 15 specimens were made of each impression material and poured by type IV stone over times(1hour, 24hours, 72hours) after mixing. 5 impressions poured after 1 hour were used for second pouring after 24hours and third pouring after 72hours. The same examiner measured each specimen 3 times after lazer scanning. All statistical tests were performed with the level of significance set at 0.05. The results indicated that significant difference at any measuring point of stone dies except the buccolingual and mesiodistal lines of the specimen made at 1hour after mixing with examixfine when measurements at 1hour, 24hours and 72hours were campared. There were significant difference between two impression materials and at every measuring point of stone dies made at second and third pouring. The length of measuring point increased significantly as time passed by and increase of the pouring frequency. However, this results are clinically acceptable except the dies of the third pouring. Under the conditions of this study, the shrinkage rate of the additional silicone rubber impression materials significantly increased as time passed by and increase of the pouring frequency.

인상채득 후 시간경과에 따른 고무인상재의 체적변화 (AN EVALUATION OF THE TIME-DEPENDENT DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS)

  • 이홍석;조석규;윤태호;박주미;송광엽
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.363-373
    • /
    • 2006
  • Statement of Problem : The accuracy and dimensional stability of elastomeric impression materials have been the subject of numerous investigation. Few studies have addressed the effect of changes in time on the dimensional stability of impression materials. Purpose: The purpose of this investigation was to evaluate the effects of elastomeric impression materials and storage time on dimensional stability. Materials and methods: A total of 75 impressions were made of epoxy resin dies mimicked prepared 3-unit fixed partial denture. The dies had 1 buccolingual, 1 mesiodistal and 1 occlusogingival lines and interpreped dot. Impression materials investigated included two polyether impression materials and three polyvinylsiloxane impression material. 15 specimens were made of each impression material and poured by type IV stone over times (30 minutes, 24 hours, 72 hours) after mixing; the same examiner measured each specimen 3 times at a magnification of 3.5$\times$. All statistical tests were performed with the level of significance set at .05. Results : The results indicated that significant difference at any measuring point of stone dies of the polyether impression materials and when measurements at 30 minutes, 24 hours, and 72 hours were compared ; the length of measuring point increased significantly as time passed by. However this result is not significant clinically. Analysis also showed significant differences at any measuring point when polyvinylsiloxane and polyether impression materials were compared and significant differences clinically. Conclusion: Under the conditions of this study, the shrinkage rate of the polyvinylsiloxane and polyether impression materials significantly increased as time passed by. The polyether impression materials showed higher shrinkage significantly, while the shrinkage rate of all five materials showed a significant time-dependent increase.

Estimation of the zone of excavation disturbance around tunnels, using resistivity and acoustic tomography

  • Suzuki Koichi;Nakata Eiji;Minami Masayuki;Hibino Etsuhisa;Tani Tomonori;Sakakibara Jyunichi;Yamada Naouki
    • 지구물리와물리탐사
    • /
    • 제7권1호
    • /
    • pp.62-69
    • /
    • 2004
  • The objective of this study is to estimate the distribution of a zone disturbed by excavation (EDZ) around tunnels that have been excavated at about 500 m depth in pre-Tertiary hard sedimentary rock. One of the most important tasks is to evaluate changes in the dynamic stability and permeability of the rock around the tunnels, by investigating the properties of the rock after the excavation. We performed resistivity and acoustic tomography using two boreholes, 5 m in length, drilled horizontally from the wall of a tunnel in pre-Tertiary hard conglomerate. By these methods, we detected a low-resistivity and low-velocity zone 1 m in thickness around the wall of the tunnel. The resulting profiles were verified by permeability and evaporation tests performed at the same boreholes. This anomalous zone matched a high-permeability zone caused by open fractures. Next, we performed resistivity monitoring along annular survey lines in a tunnel excavated in pre-Tertiary hard shale by a tunnel-boring machine (TBM). We detected anomalous zones in 2D resistivity profiles surrounding the tunnel. A low-resistivity zone 1 m in thickness was detected around the tunnel when one year had passed after the excavation. However, two years later, the resistivity around the tunnel had increased in a portion, about 30 cm in thickness, of this zone. To investigate this change, we studied the relationship between groundwater flow from the surroundings and evaporation from the wall around the tunnel. These features were verified by the relationship between the resistivity and porosity of rocks obtained by laboratory tests on core samples. Furthermore, the profiles matched well with highly permeable zones detected by permeability and evaporation tests at a horizontal borehole drilled near the survey line. We conclude that the anomalous zones in these profiles indicate the EDZ around the tunnel.

장기재령 FA 콘크리트에 대한 염화물 거동 및 확률론적 염해 내구수명 평가 (Evaluation of Chloride Behavior and Service Life in Long-Term Aged FA Concrete through Probabilistic Analysis)

  • 윤용식;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제8권3호
    • /
    • pp.276-285
    • /
    • 2020
  • 본 연구에서는 3가지 수준의 물-결합재 비를 고려한 OPC 및 FA 콘크리트를 대상으로 재령 1,095일에 촉진 염화물 확산 시험을 수행하였다. Tang's method 및 ASTM C 1202에 준하여 촉진 염화물 확산계수 및 통과 전하량을 평가하였으며 시간의 존적으로 개선되는 염화물 확산 거동을 고찰하였다. FA 배합에서는 포졸란 반응에 의해 뛰어난 염해저항성능을 나내었는데, 통과 전하량 평가 결과에 따르면 FA 콘크리트는 재령 1,095일에 "Low" 등급에서 "Very low" 등급으로 감소하였으나, OPC 배합의 경우 "Moderate" 등급에서 "Low" 등급으로 감소하였다. 염해 내구수명 해석 시 사용되는 설계변수를 정규분포 함수로 가정한 후, MCS를 기반으로 각 배합의 내구수명을 확률론적 해석 방법으로 평가하였다. FA 콘크리트에서는 OPC 콘크리트 대비 시간의 증가에 따른 내구적 파괴확률의 증가가 낮게 나타났는데 이는 FA 콘크리트의 시간의존성지수가 OPC 배합 대비 최대 3.2배 높기 때문이다. 또한 목표 내구적 파괴확률을 10%로 설정하였기 때문에 확률론적 해석에 의한 내구수명이 결정론적 해석에 의한 내구수명보다 낮게 평가되었다. 다양한 환경 하의 실태조사 및 실내 시험을 통해 각 구조물에 적합한 목표 내구적 파괴확률을 설정한다면 더욱 경제적인 내구성능 설계가 가능해지리라 사료된다.

원자력발전소 케이블 난연성능 검증 방법론 개선을 위한 연구 (A Study on Validation Methodology of Fire Retardant Performance for Cables in Nuclear Power Plants)

  • 이상규;문영섭;유성연
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.140-144
    • /
    • 2017
  • Fire protection for nuclear power plants should be designed according to the concept of "Defense in Depth" to achieve the reactor safety shutdown. This concept focuses on fire prevention, fire suppression and safe shutdown. Fire prevention is the first line of "Defense in Depth" and the licensee should establish administrative measures to minimize the potential for fire to occur. Administrative measures should include procedures to control handling and use of combustibles. Electrical cables is the major contributor of fire loads in nuclear power plants, therefore electrical cables should be fire retardant. Electrical cables installed in nuclear power plants should pass the flame test in IEEE-383 standard in accordance with NUREG-0800, "Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants". To assure the fire retardant of electrical cables during design life, both aged and unaged cable specimens should be tested in accordance with IEEE-383. It can be generally thought that the flammability of electrical cables has been increased by wearing as time passed, however the results from fire retardant tests performed in U.S.A and Korea indicate the inconsistent tendency of aging and consequential decrease in flammability. In this study, it is expected that the effective methodology for validation of fire retardant performance would be identified through the review of the results from fire retardant tests.

이상적인 음료수 공급을 위한 수질관리에 관한 연구 (Study on the Water Management to get High Quality of Drinking Water)

  • 김형석;신현덕;박경석
    • 환경위생공학
    • /
    • 제6권1호
    • /
    • pp.7-25
    • /
    • 1991
  • Until now, pure drinking water grnerally menas the water without taste, odor, general bacteria, coliform, and other exotic substance. Such a definition has been changing recently due to the finding of numerous other inorganic and organic substances unknown to us. 10 years ago, major causes of death were infectious agents and parasites contained in water, but recently, it has become apparent that some substances contained in drinking water cause cancer and heart diseases. We must drink about 2L of water everyday in order to maintain healthy condition. Waters used for drinking include tap water, well water, spring water, filtered water, etc., but the quality of drinking water has more polluted due to the industrial development and population increase. For example, industrial waste waters from industrial plants pollute the water supply sources ; toxic substances contained in the waste waters pollute the ground water sources by penetrating the geological strata, and municipal, livestock, public building waste waters also pollute the water supply sources. Sometimes, the polluted surface waters were announced to be polluted by various kinds of orgainc substance, and it is reported that the pollution of ground water by orga nic substances has few in number but high in its concectration comparing with those of surface water. As the water quality pollution level increases, so the amount of disinfectant also increase. For example, chlorine solution, one of widely used disinfectants, creates trihalomethane(THM), a carcinogen, and halogen compounds. According to Oliver, through chlorine disinfection process, humine substance and chlorine create bolatile organic halide and nonvolatile organic halide by chemical reaction. There are tens or hundreds filtering devices, but filtering principles and maintenance metjhods are different, so their efficiency tests are needed. According to Smith, the effeciency tests aginst over 30 Ameican filtering devices show that 10 devices can remove 85% of volatile organics and further studies on filtered waters are underway. In consideration of important impacts of polluted drinking water on national health, authors studied the state of water quality pollution against tap water used as drinking water, filtration device passed water, ground water, and conserved drinking water ; tested the efficiency of filtration devices for tap water ; tried to sep up the detection method by using ion chromatography based on negative ion and positive ion by using single column, and attemped the simple filtration method for general households.

  • PDF

CPS 모형 기반 스크래치 프로그래밍 학습이 언어 창의성에 미치는 영향 (Effects of Scratch Programming Learning based on CPS on Verbal Creativity)

  • 김병수;김종훈
    • 컴퓨터교육학회논문지
    • /
    • 제16권6호
    • /
    • pp.11-19
    • /
    • 2013
  • 최근 창의성의 영역 보편성 및 영역 특수성에 대한 논의가 계속되어지고 있는 시점에서 컴퓨터 프로그래밍 학습 활동 또한 창의성과 관련하여 다시 연구되어질 필요가 있다. 기존 교육용 프로그래밍 언어학습의 창의성에 대한 측정을 TTCT 도형 검사를 사용한 것에 반해, 본 연구에서는 프로그래밍 활동이 언어적 사고 양식을 더욱 요구하는 창의적 활동이라는 관점으로 바라보고 있다. 이에 따라, 본 연구에서 컴퓨터 과학의 핵심 개념을 학습 내용으로 하는 창의적 문제 해결(CPS) 모형 기반의 스크래치 프로그래밍 학습을 개발하였다. 이 학습 프로그램을 4, 5학년 학생 17명을 대상으로 5일간 4차시씩 총 20차시 적용하고, 정규성이 검증된 이 실험집단에 TTCT 언어 검사의 평균 표준점수(100)로 t검정을 실시한 결과 언어 창의성의 세가지 하위 요인(유창성, 융통성, 독창성)과 창의성 지수(세 요인의 평균 표준점수)가 유의미하게 증진되었다.

  • PDF

Morestan 합제의 Eimeria tenella 오오시스트에 대한 살멸효과 (Oocysticidal effects of morestan combination preparations against oocysts of Eimeria tenella)

  • 노재욱;김병기;오화균
    • 대한수의학회지
    • /
    • 제34권2호
    • /
    • pp.335-338
    • /
    • 1994
  • The tests on the oocysticidal effects of three formulations (75% o-dichlorobenzene, 7.5% cresol combined with morestan 0.5%, 1.0%, 1.5%, respectively) against immature oocysts of Eimeria tenella, were carried out. A o-dichlorobenzene preparation (72.5% o-dichlorobenzene, 7.5% cresol) on the market was selected and tested as the control. The tests were divided into two ways, the one was evaluated at different dilutions and contact times. The other was performed at different storage days. The test results are summarized as follows. Oocysticidal effects of 100% were revealed at 1 to 3 hours contact time of all morestan combined preparations. On the other hand, the perfect oocysticidal effect was revealed only at 24 hours exposure time of 100 times dilution among dilutes of control preparation. Combined rate of morestan was higher, oocysticidal effect was better. In the latter test, all morestan combined formulations had 100% of oocysticidal effect up to 5 days storage after dilution and 86.4% to 96.7% at two weeks storage after dilution, whereas the oocysticidal effects of the control preparation was gradually decreased by the storage time was passed and there was no effect at 2 weeks storage after dilution. With these results, morestan combined preparations have synergistic effect against oocysts of E tenella and can be used as the most effective oocysticidal disinfectant for broiler industry in future.

  • PDF

화순항내 준설토사의 양빈재 유효활용을 위한 적합성 평가 (An Adaptedness Assessment for Beach Nourishment Utilization of Dredged Materials in Hwasun-Port)

  • 최진환;이상혁
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2940-2944
    • /
    • 2015
  • 화순항에서 유효활용을 위한 준설토의 오염도 분석결과, Ni이 기준치를 전지점에서 초과하는 것으로 나타났다. 그러나 개정된 유효활용기준에 의하면 기준치를 초과하더라도 인위적인 오염원이 없고 펄의 평균 무게 비율이 10%미만이며 생태독성 시험을 통과하였을 경우 양빈재로 활용이 가능하다. 따라서 연구방법으로 해양환경공정시험법에 의한 펄의 평균무게 비율조사와 생태독성실험을 실시하였다. 펄의 평균 무게 비율은 5.37%로 기준치인 10%을 하회하는 것으로 조사되었다. 발광 박테리아를 이용한 생태독성실험 결과는 상대발광저해율이 0~9.13%로 독성없음으로 판정되었으며 저서성 단각류를 이용한 시험에서도 대조구와 시료의 상대평균생존률이 0%로 독성없음으로 판정되었다 따라서, 개정된 유효활용기준을 모두 만족하므로 양빈재로 사용이 가능한 것으로 적합성이 평가되었다.

휴대용 메모리형 방사선 경보장치 개발 (Development of Portable Memory Type Radiation Alarm Monitor)

  • 손중권;이명찬;송명재
    • Journal of Radiation Protection and Research
    • /
    • 제22권4호
    • /
    • pp.263-272
    • /
    • 1997
  • 방사선 작업자의 과피폭을 방지하기 위해 방사선 작업 도중 이상 사태가 발생할 경우 광 음경보가 발생한 후 이상 사태 발생 90분, 발생 30분간의 방사선량과 방사선량율 변화를 저장하고 외부 PC로 데이터를 전송한 후 사고를 분석하여 차후에 같은 유형의 방사선 사고를 사전에 예방할 수 있도록 고안된 방사선 경보장치를 개발하였다. 이 방사선 경보장치의 특징은 넓은 방사선 측정 범위(10mR/h $\sim$ 100 R/h), 방사선 준위의 기록 및 기억, PC와의 data처리 기능, 휴대성, 교정 기능에 의한 높은 정밀도(${\pm}5%$), 인지도가 높은 강력한 경보기능 채택 등이다. 개발된 방사선 경보장치의 물리적 환경 적응시험을 가장 엄격한 ANSI N42.17A의 표준 시험조건에 의거하여 온도, 습도, 진동, 전자기파 간섭 등에 관해 한국표준과학연구원에서 수행하였으며 모든 시험항목을 통과하였다.

  • PDF