• 제목/요약/키워드: Passed tests

검색결과 148건 처리시간 0.031초

임계압력 근처에서의 환형관 채널에 대한 열전달 특성 연구 (Heat Transfer Characteristics of an Annulus Channel Cooled with R-134a Fluid near the Critical Pressure)

  • 홍성덕;천세영;김세윤;백원필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2094-2099
    • /
    • 2004
  • An experimental study on heat transfer characteristics near the critical pressure has been performed with an internally-heated vertical annular channel cooled by R-134a fluid. Two series of tests have been completed: (a) steady-state critical heat flux (CHF) and (b) heat transfer tests for pressure reduction transients through the critical pressure. In the present experimental range, the steady-state CHF decreases with the increase of the system pressure For a fixed inlet mass flux and subcooling, the CHF falls sharply at about 3.8 MPa and shows a trend toward converging to zero as the pressure approaches the critical point of 4.059 MPa. The CHF phenomenon near the critical pressure does not lead to an abrupt temperature rise of the heated wall because the CHF occurred at remarkably low power levels. In the pressure reduction transient experiments, as soon as the pressure passed through the critical pressure, the wall temperatures rise rapidly up to a very high value due to the occurrence of the departure from nucleate boiling. The wall temperature reaches a maximum at the saturation point of the outlet temperature, then tends to decrease gradually.

  • PDF

산업용 인버터의 가속 피로수명 평가에 관한 연구 (A Study on Accelerated Fatigue Life Testing for Industrial Inverter)

  • 이상훈;김원진
    • 한국기계가공학회지
    • /
    • 제21권6호
    • /
    • pp.67-73
    • /
    • 2022
  • Industrial inverters are used in a variety of fields for electric power supply. They may be exposed to vibration and heat once they are installed. This study focused on a framework of accelerated life testing of an industrial inverter considering fatigue damage as the primary source of deterioration. Instead of analyzing detailed failure mechanisms and the product's vulnerability to them, the potential of fatigue failure is considered using the fatigue damage spectrum calculated from the environmental vibration signals. The acceleration and temperature data were gathered using field measurement and spectral analysis was conducted to calculate the vibration signal's power spectral density (PSD). The fatigue damage spectrum is then calculated from the input PSD data and is used to design an accelerated fatigue life testing. The PSD for the shaker table test is derived that has the equivalent fatigue damage to the original input signal. The tests were performed considering the combined effect of random vibration and elevated temperature, and the product passed all the planned tests. It was successfully demonstrated that the inverter used in this study could survive environmental vibration up to its guarantee period. The fatigue damage spectrum can effectively be used to design accelerated fatigue life testing.

Condition assessment of aged underground water tanks-Case study

  • Zafer Sakka;Ali Saleh;Thamer Al-Yaqoub;Hasan Karam;Shaikha AlSanad;Jamal Al-Qazweeni;Mohammad Mosawi;Husain Al-Baghli
    • Structural Engineering and Mechanics
    • /
    • 제90권5호
    • /
    • pp.493-504
    • /
    • 2024
  • This paper presents the methodology and results for the investigation of the structural safety of 40 aged underground water tanks to support the weight of photovoltaic (PV) systems that were supposed to be placed on their roof reinforced concrete (RC) slabs. The investigation procedure included (1) review of available documents; (2) visual inspection of the roof RC slabs; (3) carrying out a series of nondestructive (ND) tests; and (4) analysis of results. Out of the 40 tanks, eleven failed the visual inspection phase and were discarded from further investigation. The roof RC slabs of the tanks that passed the visual inspection were subjected to a series of ND tests that included infrared thermography, impact echo, ultrasonic pulse velocity (UPV), Schmidt hammer, concrete core compressive strength, and water-soluble chloride content. The NDT results proved that eight more tanks were not suitable to support the PV systems. Based on the results of the visual inspection and testing, a probabilistic decision-making criterion was established to reach a decision regarding the structural integrity of the roof slabs. The study concluded that the condition of the drainage filter was essential in protecting the tanks and its intact presence can be used as a strong indication of the structural integrity of the roof RC slabs.

'전산화 신경인지기능검사'를 통한 학령기 정상아동의 신경심리학적 특성 (The Neuropsychological Characteristics of the Elementary School Aged Child by 'Computerized Neurocognitive Function Test')

  • 이종범;김진성;서완석;신현진;배대석;이준엽
    • 정신신체의학
    • /
    • 제11권2호
    • /
    • pp.118-136
    • /
    • 2003
  • 연구목적: '컴퓨터화된 검사'인 전산화 신경인지기능검사가 학령기 정상아동의 신경심리학적 발달특성을 반영하는 지를 알아보고자 하였다. 방 법: 2002년 6월부터 2003년 1월까지 평균 범위 이상의 지능을 유지하고 있고, 배제기준(rule out criteria)을 통과한 학년별 남녀 각각 10명씩, 120명의 정상아동에게 K-ABC, K-PIC 및 전산화 신경인지기능검사를 실시하였다. 결 과: 정상아동의 표집과정에서 지능의 통제와 엄격한 배제기준의 적용을 통하여 전체 아동의 21.1%가 분석과정에서 제외되었지만 학년별 인원과 성비를 동일하게 유지하면서 지능의 차이가 없는 연구 대상자 120명을 선발할 수 있었다. 학년에 따른 CNFT의 결과비교에서, 주의력 검사, 기억력 검사 및 고위인지기능검사 대부분에서 학년에 따른 유의한 차이가 있음을 확인하였으며, 주로 초등학교 저학년(1학년과 2학년)과 고학년(5학년과 6학년)에서 나타남을 확인하였다. 주의력 검사의 경우, 학년이 증가함에 따라 점차 수행이 행상되는 특성을 확인하였고, 단기기억력 검사에서 역방향 검사와 순방향검사의 차이, 연령에 따른 수행차이가 선행연구와 동일함을 발견할 수 있었다. 회상(recall) 과제로 구성된 언어청각검사와 재인(recognition)과제로 구성된 시각도형기억검사 또한 대인검사로 실시된 선행연구에서와 마찬가지로 연령에 따른 변화특성이 확인되었다. 고위인지기능검사에서도 주의력 검사 및 기억력 검사에서 연령에 따른 변화특성이 발견되었다. 결 론: 본 연구에서 성인을 대상으로 하여 개발된 CNFT가 아동의 신경심리학적 특성을 적절히 반영하고 있음을 확인할 수 있었고, 이를 위하여서는 연구 대상자의 표집단계에서부터 지적수준의 통제와 더불어 엄격한 배제기준의 적용이 필요함을 알수 있었다.

  • PDF

성능시험을 통한 경전철 차량의 주행특성 비교 고찰 (A Comparison on Running Characteristics of Light Rail Transit Vehicles through Performance Test)

  • 전창성;전홍규;김영국;박태원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.47-50
    • /
    • 2011
  • Test Results of noise, ride comfort and vibration tests are investigated for three kinds of light rail transit vehicles which have passed the performance test and the test criteria has been satisfied. Noise level of light rail transit vehicles was 64~69dB(A) at stop and 74~75dB(A) when operated at full speed. The ride comfort index according to UIC 513R was 2.02 to 2.45. Vibration level of rubber tired light rail transit vehicle was from 'normal' to 'good' and that of iron wheel light rail transit vehicle was 'good' to 'excellent'. These data are the results for three kinds of light rail transit vehicles and more data can be accumulated after further performance test. These data can be used for a reference for the design of light rail transit vehicles.

  • PDF

콘크리트중의 염소이온 확산계수 추정 실험법의 비교 (Comparision of Test Methods for Estimating Chloride Ion Diffusion Coefficient in Concrete)

  • 문한영;김홍삼;문재흠;한아름
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.787-790
    • /
    • 1999
  • To estimate durability of reinforced concrete structures located in or nearby seawater, many different kinds of accelerated tests for evaluation of chloride ion permeation in concrete were proposed. At present the only standardized test is the ASTM C 1202(RCP test). This test method is used to estimate the concrete's resistivity of the chloride penetration in concrete by using the total charges passed and sometimes used to calculate the chloride diffusion coefficients. However, this test may lead to an erroneous chloride diffusion coefficient. So this test method was compared with the modified Dhir's test and the traditional concentration diffusion test. Experimental results showed that the diffusion coefficients determined the RCP test and the PD Index gave wrongous values, but the diffusion coefficient acquired by considering a migration term was nearly the same to the CD Test.

  • PDF

원형강관에 부착된 ㄱ형 perfobond 리브 전단연결재의 정적실험 (Static Tests of ㄱ Type Perfobond Rib Shear Connectors when using Steel Tube)

  • 이흥수;정철헌;최외호;김석기;유성근;김영호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.778-781
    • /
    • 2004
  • This paper summarizes the results of push-out test specimens with a new type of shear connector called ㄱ type perfobond rib. This connector is a flat steel plate with a number of holes punched through and strengthen rib's head part. According to experiment result, ㄱ type perfobond rib shear connector appeared that resistance force is increased than stud shear connector by $108\%$ and perfobond rib shear connector by $26\%$. The results obtained indicate that the perfobond rib connector is a viable alternative to the headed studs. An appreciable improvement in the shear capacity of the connection was observed when additional reinforcing bars were passed through the perfobond rib holes. For composite beams with concrete filled steel tubes, ㄱ type perfobond shear connectors exhibit adequate ductility and substantially higher capacities.

  • PDF

생물학적 검정법을 이용한 소규모 수계내 수질 오염물질의 환경독성 평가 -상추씨 발아시험과 Microtox 시험 비교- (Evaluation of Environmental Toxicities for Priority Water Pollutants in a Small Watershed by Bioassays - Comparision between Lettuce Seed Germination Test and Microtox Bioassay -)

  • 이지나;황인영
    • Environmental Analysis Health and Toxicology
    • /
    • 제14권4호
    • /
    • pp.135-144
    • /
    • 1999
  • Environmental toxicities of priority water pollutants were evaluated by two selected bioassays, Lettuce seed germination/elongation test and Microtox acute toxicity test. Toxic chemicals (heavy metals, polycyclic aromatic hydrocarbons, and phenolic compounds) inhibited the germination rate and root elongation of Lettuce seed, as well as the bioluminescence of Microtox bacteria. When test biota were exposed to target chemicals, the sensitivity of Lettuce bioassay was relatively lower than that of Microtox bioassay. However, Lettuce bioassay may be a good candidate for prescreening the environmental toxicities of priority water pollutants, since the testing method with Lettuce seed was relatively easier and more economic than with Microtox bacteria. Toxicity tests were conducted to compare the validity and sensitivity of both bioassays for sediment from a small stream passed through urban area as well as leachate from a municipal solid waste landfill. From experimental results, we found that Lettuce test and Microtox test are compensated each other as a battery of bioassay for evaluating the environmental toxicities of field samples obtained from a small stream contaminated by pollutants.

  • PDF

고정도 챔퍼링 공구 셋트의 개발 (A Development of High-Precision Chamfering Tool Set)

  • 김철;최용훈;소병환;김창호
    • 한국기계가공학회지
    • /
    • 제14권1호
    • /
    • pp.117-122
    • /
    • 2015
  • There has been a string of negligent accidents at the seaside, and there is presently a shortage of professional equipment to deal with such accidents. The purpose of this paper is to assess the development of a rescue lift. The critical load of a support pipe, and the stability of the rescue lift, were investigated using structural analysis. Critical-load analysis was used to study the effects of variations in the pipe length and the ratio of the moment of inertia. The total weight of the developed rescue lift is approximately 20.7 kg, and the lift passed the load tests.

구조해석을 통한 구조용 인양기 개발 (Rescue Lift Development Using Structural Analysis)

  • 손인수;김창호;배성호;이준용
    • 한국기계가공학회지
    • /
    • 제14권1호
    • /
    • pp.111-116
    • /
    • 2015
  • There has been a string of negligent accidents at the seaside. In addition, there is a shortage of professional equipment to deal with these negligent accidents at present. The purpose of this paper is to assess the development of a rescue lift using a structural analysis. The critical load of a support pipe on the rescue lift is investigated in this paper. The stability of the rescue lift is also determined in a structural analysis. In the critical load analysis, the effects of variations in the pipe length and the ratio of the moment of inertia are investigated. The total weight of the developed rescue lift is approximately 20.7kg, and the lift passed the load tests.