• Title/Summary/Keyword: Passed tests

Search Result 148, Processing Time 0.025 seconds

Heat Transfer Characteristics of an Annulus Channel Cooled with R-134a Fluid near the Critical Pressure (임계압력 근처에서의 환형관 채널에 대한 열전달 특성 연구)

  • Hong, Sung-Deok;Chun, Se-Young;Kim, Se-Yun;Baek, Won-Pil
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2094-2099
    • /
    • 2004
  • An experimental study on heat transfer characteristics near the critical pressure has been performed with an internally-heated vertical annular channel cooled by R-134a fluid. Two series of tests have been completed: (a) steady-state critical heat flux (CHF) and (b) heat transfer tests for pressure reduction transients through the critical pressure. In the present experimental range, the steady-state CHF decreases with the increase of the system pressure For a fixed inlet mass flux and subcooling, the CHF falls sharply at about 3.8 MPa and shows a trend toward converging to zero as the pressure approaches the critical point of 4.059 MPa. The CHF phenomenon near the critical pressure does not lead to an abrupt temperature rise of the heated wall because the CHF occurred at remarkably low power levels. In the pressure reduction transient experiments, as soon as the pressure passed through the critical pressure, the wall temperatures rise rapidly up to a very high value due to the occurrence of the departure from nucleate boiling. The wall temperature reaches a maximum at the saturation point of the outlet temperature, then tends to decrease gradually.

  • PDF

A Study on Accelerated Fatigue Life Testing for Industrial Inverter (산업용 인버터의 가속 피로수명 평가에 관한 연구)

  • Lee, Sanghoon;Kim, Won-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.6
    • /
    • pp.67-73
    • /
    • 2022
  • Industrial inverters are used in a variety of fields for electric power supply. They may be exposed to vibration and heat once they are installed. This study focused on a framework of accelerated life testing of an industrial inverter considering fatigue damage as the primary source of deterioration. Instead of analyzing detailed failure mechanisms and the product's vulnerability to them, the potential of fatigue failure is considered using the fatigue damage spectrum calculated from the environmental vibration signals. The acceleration and temperature data were gathered using field measurement and spectral analysis was conducted to calculate the vibration signal's power spectral density (PSD). The fatigue damage spectrum is then calculated from the input PSD data and is used to design an accelerated fatigue life testing. The PSD for the shaker table test is derived that has the equivalent fatigue damage to the original input signal. The tests were performed considering the combined effect of random vibration and elevated temperature, and the product passed all the planned tests. It was successfully demonstrated that the inverter used in this study could survive environmental vibration up to its guarantee period. The fatigue damage spectrum can effectively be used to design accelerated fatigue life testing.

Condition assessment of aged underground water tanks-Case study

  • Zafer Sakka;Ali Saleh;Thamer Al-Yaqoub;Hasan Karam;Shaikha AlSanad;Jamal Al-Qazweeni;Mohammad Mosawi;Husain Al-Baghli
    • Structural Engineering and Mechanics
    • /
    • v.90 no.5
    • /
    • pp.493-504
    • /
    • 2024
  • This paper presents the methodology and results for the investigation of the structural safety of 40 aged underground water tanks to support the weight of photovoltaic (PV) systems that were supposed to be placed on their roof reinforced concrete (RC) slabs. The investigation procedure included (1) review of available documents; (2) visual inspection of the roof RC slabs; (3) carrying out a series of nondestructive (ND) tests; and (4) analysis of results. Out of the 40 tanks, eleven failed the visual inspection phase and were discarded from further investigation. The roof RC slabs of the tanks that passed the visual inspection were subjected to a series of ND tests that included infrared thermography, impact echo, ultrasonic pulse velocity (UPV), Schmidt hammer, concrete core compressive strength, and water-soluble chloride content. The NDT results proved that eight more tanks were not suitable to support the PV systems. Based on the results of the visual inspection and testing, a probabilistic decision-making criterion was established to reach a decision regarding the structural integrity of the roof slabs. The study concluded that the condition of the drainage filter was essential in protecting the tanks and its intact presence can be used as a strong indication of the structural integrity of the roof RC slabs.

The Neuropsychological Characteristics of the Elementary School Aged Child by 'Computerized Neurocognitive Function Test' ('전산화 신경인지기능검사'를 통한 학령기 정상아동의 신경심리학적 특성)

  • Lee, Jong-Bum;Kim, Jin-Sung;Seo, Wan-Seok;Shin, Hyoun-Jin;Bai, Dai-Seg;Lee, Jun-Heob
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.11 no.2
    • /
    • pp.118-136
    • /
    • 2003
  • Objective: This study is to examine the neuropsychological and developmental characteristics of the Computerized Neurocognitive Function Test among normal children in elementary school. Methods: K-ABC, K-PIC, and Computerized Neurocognitive Function Test were performed to the 120 body of normal children(10 of each male and female) from June, 2002 to January, 2003. Those children had over the average of intelligence and passed the rule out criteria. One-way ANOVA and Bonferroni were used for statistical analysis. Results: In sampling of normal children in elementary school, the control of intelligence level and strict rule out criteria were applied. As a result, although 21.1% were excluded from of total participants, the children that passed the rule out criteria had over the average of intelligence and not differ in the intelligence level among the graders. Comparing Computerized Neurocognitive Function Test results among the graders, almost of variables had significant difference among the graders and especially between the 1st to 2nd and the 5th to 6th graders. In the attention tests, as rising the graders, the performance of tests were improved. In the short-term memory tests, the difference between forward and backward tests were same as the previous research result. The verbal auditory learning test composed of recall task and visual figure memory test composed of recognition task were same as the previous research result using the individual power or achievement test and also as rising the graders, the performance of those tests were improved. The higher cognitive function tests had the same results with other tests. Conclusion: The Computerized Neurocognitive Function Test devised for adult can be used of assessing child neuropsychological characteristics. For this objective, more strict sampling criteria, control of the intelligence and psychopathology were needed.

  • PDF

A Comparison on Running Characteristics of Light Rail Transit Vehicles through Performance Test (성능시험을 통한 경전철 차량의 주행특성 비교 고찰)

  • Jeon, Chang-Sung;Jeon, Hong-Kyu;Kim, Young-Guk;Park, Tae-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.47-50
    • /
    • 2011
  • Test Results of noise, ride comfort and vibration tests are investigated for three kinds of light rail transit vehicles which have passed the performance test and the test criteria has been satisfied. Noise level of light rail transit vehicles was 64~69dB(A) at stop and 74~75dB(A) when operated at full speed. The ride comfort index according to UIC 513R was 2.02 to 2.45. Vibration level of rubber tired light rail transit vehicle was from 'normal' to 'good' and that of iron wheel light rail transit vehicle was 'good' to 'excellent'. These data are the results for three kinds of light rail transit vehicles and more data can be accumulated after further performance test. These data can be used for a reference for the design of light rail transit vehicles.

  • PDF

Comparision of Test Methods for Estimating Chloride Ion Diffusion Coefficient in Concrete (콘크리트중의 염소이온 확산계수 추정 실험법의 비교)

  • 문한영;김홍삼;문재흠;한아름
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.787-790
    • /
    • 1999
  • To estimate durability of reinforced concrete structures located in or nearby seawater, many different kinds of accelerated tests for evaluation of chloride ion permeation in concrete were proposed. At present the only standardized test is the ASTM C 1202(RCP test). This test method is used to estimate the concrete's resistivity of the chloride penetration in concrete by using the total charges passed and sometimes used to calculate the chloride diffusion coefficients. However, this test may lead to an erroneous chloride diffusion coefficient. So this test method was compared with the modified Dhir's test and the traditional concentration diffusion test. Experimental results showed that the diffusion coefficients determined the RCP test and the PD Index gave wrongous values, but the diffusion coefficient acquired by considering a migration term was nearly the same to the CD Test.

  • PDF

Static Tests of ㄱ Type Perfobond Rib Shear Connectors when using Steel Tube (원형강관에 부착된 ㄱ형 perfobond 리브 전단연결재의 정적실험)

  • Lee Heung-Su;Chung Chul-Hun;Choi Wae-Ho;Kim Seok-Ki;You Sung-Kun;Kim Young-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.778-781
    • /
    • 2004
  • This paper summarizes the results of push-out test specimens with a new type of shear connector called ㄱ type perfobond rib. This connector is a flat steel plate with a number of holes punched through and strengthen rib's head part. According to experiment result, ㄱ type perfobond rib shear connector appeared that resistance force is increased than stud shear connector by $108\%$ and perfobond rib shear connector by $26\%$. The results obtained indicate that the perfobond rib connector is a viable alternative to the headed studs. An appreciable improvement in the shear capacity of the connection was observed when additional reinforcing bars were passed through the perfobond rib holes. For composite beams with concrete filled steel tubes, ㄱ type perfobond shear connectors exhibit adequate ductility and substantially higher capacities.

  • PDF

Evaluation of Environmental Toxicities for Priority Water Pollutants in a Small Watershed by Bioassays - Comparision between Lettuce Seed Germination Test and Microtox Bioassay - (생물학적 검정법을 이용한 소규모 수계내 수질 오염물질의 환경독성 평가 -상추씨 발아시험과 Microtox 시험 비교-)

  • 이지나;황인영
    • Environmental Analysis Health and Toxicology
    • /
    • v.14 no.4
    • /
    • pp.135-144
    • /
    • 1999
  • Environmental toxicities of priority water pollutants were evaluated by two selected bioassays, Lettuce seed germination/elongation test and Microtox acute toxicity test. Toxic chemicals (heavy metals, polycyclic aromatic hydrocarbons, and phenolic compounds) inhibited the germination rate and root elongation of Lettuce seed, as well as the bioluminescence of Microtox bacteria. When test biota were exposed to target chemicals, the sensitivity of Lettuce bioassay was relatively lower than that of Microtox bioassay. However, Lettuce bioassay may be a good candidate for prescreening the environmental toxicities of priority water pollutants, since the testing method with Lettuce seed was relatively easier and more economic than with Microtox bacteria. Toxicity tests were conducted to compare the validity and sensitivity of both bioassays for sediment from a small stream passed through urban area as well as leachate from a municipal solid waste landfill. From experimental results, we found that Lettuce test and Microtox test are compensated each other as a battery of bioassay for evaluating the environmental toxicities of field samples obtained from a small stream contaminated by pollutants.

  • PDF

A Development of High-Precision Chamfering Tool Set (고정도 챔퍼링 공구 셋트의 개발)

  • Kim, Chul;Choi, Yong-Hoon;Sho, Byung-Hwan;Kim, Chang-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.1
    • /
    • pp.117-122
    • /
    • 2015
  • There has been a string of negligent accidents at the seaside, and there is presently a shortage of professional equipment to deal with such accidents. The purpose of this paper is to assess the development of a rescue lift. The critical load of a support pipe, and the stability of the rescue lift, were investigated using structural analysis. Critical-load analysis was used to study the effects of variations in the pipe length and the ratio of the moment of inertia. The total weight of the developed rescue lift is approximately 20.7 kg, and the lift passed the load tests.

Rescue Lift Development Using Structural Analysis (구조해석을 통한 구조용 인양기 개발)

  • Son, In-Soo;Kim, Chang-Ho;Bae, Sung-Ho;Lee, Joon-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.1
    • /
    • pp.111-116
    • /
    • 2015
  • There has been a string of negligent accidents at the seaside. In addition, there is a shortage of professional equipment to deal with these negligent accidents at present. The purpose of this paper is to assess the development of a rescue lift using a structural analysis. The critical load of a support pipe on the rescue lift is investigated in this paper. The stability of the rescue lift is also determined in a structural analysis. In the critical load analysis, the effects of variations in the pipe length and the ratio of the moment of inertia are investigated. The total weight of the developed rescue lift is approximately 20.7kg, and the lift passed the load tests.