• 제목/요약/키워드: Pass-by noise test

검색결과 66건 처리시간 0.027초

초전도베어링을 이용한 300 Wh급 플라이휠 에너지저장장치의 고속운전시험 (High Speed Operating Test of a 300Wh Flywheel Energy Storage System Using Superconductor Bearings)

  • 김영철;최상규;성태현;이준성;한영희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.514-520
    • /
    • 2001
  • A 300Wh class flywheel energy storage system using high Tc superconductor bearings(HTC SFES) is being developed by KIMM and KEPRI. HTC SFES consists of a flywheel rotor, superconductor bearings, a motor/generator and its controller, touch-down bearings, vacuum chamber, etc. Stiffness and damping values of superconductor bearings were experimentally estimated to be 67,700N/m and 29Ns/m respectively. The present HTC SFES was designed to have maximum operating speed of 33000 rpm, which is far above 2 rigid body mode critical speeds of 645rpm and 1,275rpm. Leaf-spring type touch-down bearing were utilized to have the system pass safely through the system critical speeds. It has been experimentally verified that the system can run stably up to 28,000 rpm so that HTC SFES is now expected to reach up to its maximum design speed of 33,000rpm without any difficulties. The Halbach array motor & generator has also been proven its effectiveness on transferring electrical energy to a rotaing composite flywheel in kinetic form.

  • PDF

모터 구동시스템 시험을 위한 개선된 프로그램어블 다이나모메터 제어 (A Improved Programmable-Dynamometer Control For Motor Drive Systems Testing)

  • 김길동;박현준;조정민;전기영;오봉환;이훈구;한경희
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권5호
    • /
    • pp.211-220
    • /
    • 2003
  • The control method of programmable dynamometer for overall test of machine is to load the reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of meter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for meter torque of programmable dynamometer. Therefore, this kind of system could not perform dynamic and nonlinear load. In this paper, the control method using the load torque observer without a measure for torque transducer is Proposed. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction meter. Therefore, the torque controller is not affected by a load torque disturbance. To verify a superiority of the proposed control algorithm, the analysis for a root locus of a conventional control method and the proposed one, and simulation and experiment is performed. Therefore we hope to be extended in industrial application.

구동 시스템 시험을 위한 고성능 다이나모메터 제어 (A Highly Efficient Dynamometer Control For Motor Drive Systems Testing)

  • 김길동;신정렬;이한민;이우동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1291-1293
    • /
    • 2004
  • The control method of programmable dynamometer for overall test of machine is to load the reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of meter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for moter torque of programmable dynamometer. Therefore, this kind of system could not perform dynamic and nonlinear load. In this paper, the control method using the load torque observer without a measure for torque transducer is proposed. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction meter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

UKF를 적용한 레이저 관성항법장치의 외란에 대한 초기정렬 성능분석 (Performance Analysis in Disturbance on Initial Alignment of Laser Inertial Navigation System Using Unscented Kalman Filter)

  • 오주현
    • 한국군사과학기술학회지
    • /
    • 제17권4호
    • /
    • pp.537-543
    • /
    • 2014
  • RLG(Ring Laser Gyroscope) is a main device of LINS(Laser Inertial Navigation System). RLG has the lock-in region in which there is no output signal. To alleviate the lock-in problem, a mechanical oscillation, the dither motion, is applied on RLG. A LPF(Low Pass Filter) is usually used on the output of RLG and accelerometer to remove the noise that is made by the dither motion. When the LINS is induced the disturbance during the initial alignment, it takes more time on alignment due to the use of the LPF and a fixed gain controller. In this paper, an initial alignment using UKF(Unscented Kalman Filter) is designed and analysed. Analysis include comparison between conventional initial alignment loop using fixed gain type controller and proposed initial alignment using UKF. Moreover, Disturbance inducing test results are demonstrated.

Compensation of the Error Rate for the Non-invasive Sphygmomanometer System Using a Tactile Sensor

  • Jeong, In-Cheol;Choi, Yoo-Nah;Yoon, Hyung-Ro
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.136-141
    • /
    • 2007
  • The Purpose Of This Paper Is To Use A Tactile Sensor To Compensate The Error Rate. Most Automated Sphygmomanometers Use The Oscillometric Method And Characteristic Ratio To Estimate Systolic And Diastolic Blood Pressure. However, Based On The Fact That Maximum Amplitude Of The Oscillometric Waveform And Characteristic Ratio Are Affected By Compliance Of The Aorta And Large Arteries, A Method To Measure The Artery Stiffness By Using A Tactile Sensor Was Chosen In Order To Integrate It With The Sphygmomanometer In The Future Instead Of Using Photoplethysmography. Since Tactile Sensors Have Very Weak Movements, Efforts Were Made To Maintain The Subject's Arm In A Fixed Position, And A 40hz Low Pass Filter Was Used To Eliminate Noise From The Power Source As Well As High Frequency Noise. An Analyzing Program Was Made To Get Time Delay Between The First And Second Peak Of The Averaged Digital Volume Pulse(${\Delta}t_{dvp}$), And The Subject's Height Was Divided By ${\Delta}t_{dvp}$ To Calculate The Stiffness Index Of The Arteries($Si_{dvp}$). Regression Equations Of Systolic And Diastolic Pressure Using $Si_{dvp}$ And Mean Arterial Pressure(Map) Were Computed From The Test Group (60 Subjects) Among A Total Of 121 Subjects(Age: $44.9{\pm}16.5$, Male: Female=40:81) And Were Tested In 61 Subjects To Compensate The Error Rate. Error Rates Considering All Subjects Were Systolic $4.62{\pm}9.39mmhg$, And Diastolic $14.40{\pm}9.62mmhg$, And Those In The Test Set Were $3.48{\pm}9.32mmhg,\;And\;14.34{\pm}9.67mmhg$ Each. Consequently, Error Rates Were Compensated Especially In Diastolic Pressure Using $Si_{dvp}$, Various Slopes From Digital Volume Pulse And Map To Systolic-$1.91{\pm}7.57mmhg$ And Diastolic $0.05{\pm}7.49mmhg$.

풍하중 저감형 방음판의 실증 연구 (An Empirical Study of Soundproof wall with Reduced Wind Load)

  • 최진규;이찬영
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.272-278
    • /
    • 2018
  • 최근 도시개발과 생활수준의 향상으로 인해 교통량이 크게 증가하고 있으며, 이와 더불어 증가되는 도로 소음으로 인해 많은 민원이 제기되고 있다. 이에 대한 대책으로 도로변에 높은 방음벽이 설치되고 있으나 방음벽 주요 설계 요건인 풍하중은 공사비의 기하급수적인 증가뿐만 아니라 방음벽 높이 제한의 요인으로 작용하게 된다. 이에 본 연구에서는 기존 방음벽 수준의 차음 성능과 더불어 풍하중을 획기적으로 저감할 수 있는 우수한 가격 경쟁력의 방음벽을 개발 하는 것을 목적으로 한다. 본 연구 대상의 방음판은 헬름홀츠의 공명기 이론을 바탕으로 공기와 같은 유체는 통과하고 소음은 저감할 수 있는 신개념 통기형 방음판에 해당된다. 본 연구에서는 실 크기의 금속재 방음판을 제작하여 음압투과손실실험, 풍동실험 및 재료품질 실험을 수행하여 고속도로의 품질기준을 만족하는 결과를 도출하였다. 또한 신뢰성을 검증하기 위해 현장에 제작 및 설치를 하고 시간대 별로 소음을 측정하여 방음판의 소음 차단 효과를 확인하였다. 향후 도로에 통풍형 방음벽을 설치할 경우 높은 소음 차단 효과로 인하여 쾌적한 생활환경을 조성할 수 있을 것으로 예상된다.

저잡음 · 고신뢰성 Differential Paired eFuse OTP 메모리 설계 (Design of Low-Noise and High-Reliability Differential Paired eFuse OTP Memory)

  • 김민성;김려연;학문초;하판봉;김영희
    • 한국정보통신학회논문지
    • /
    • 제17권10호
    • /
    • pp.2359-2368
    • /
    • 2013
  • 본 논문에서는 power IC에서 파워가 ON되어있는 동안 입력 신호인 RD(Read) 신호 포트에 glitch와 같은 신호 잡음이 발생하더라도 파워-업(power-up)시 readout된 DOUT 데이터를 유지하면서 다시 읽기 모드로 재진입하지 못하도록 막아주는 IRD(Internal Read Data) 회로를 제안하였다. 그리고 pulsed WL(Word-Line) 구동방식을 사용하여 differential paird eFuse OTP 셀의 read 트랜지스터에 수 십 ${\mu}A$의 DC 전류가 흐르는 것을 방지하여 blowing 안된 eFuse 링크가 EM(Electro-Migration)에 의해 blowing되는 것을 막아주어 신뢰성을 확보하였다. 또한 program-verify-read 모드에서 프로그램된 eFuse 저항의 변동을 고려하여 가변 풀-업 부하(variable pull-up load)를 갖는 센싱 마진 테스트 기능을 수행하는 동시에 프로그램 데이터와 read 데이터를 비교하여 PFb(pass fail bar) 핀으로 비교 결과를 출력하는 회로를 설계하였다. $0.18{\mu}m$ 공정을 이용하여 설계된 8-비트 eFuse OTP IP의 레이아웃 면적은 $189.625{\mu}m{\times}138.850{\mu}m(=0.0263mm^2)$이다.

플럭스게이트 센서 기반 드론 자력탐사 시스템 개발 (A Development of Fluxgate Sensor-based Drone Magnetic Exploration System)

  • 노명근;이슬기;이희순;안태규
    • 지구물리와물리탐사
    • /
    • 제23권3호
    • /
    • pp.208-214
    • /
    • 2020
  • 본 연구에서는 플럭스게이트(fluxgate) 센서를 탑재한 드론 자력탐사 시스템 시작품(proto-type)을 개발하였다. 시스템의 하드웨어는 플럭스게이트 자력센서, 관성측정장치(inertial measurement unit, IMU), GPS, 통신 모듈로 구성되어 있다. 또한 측정된 자료를 지상제어시스템(ground control system, GCS)으로 실시간 전송하는 모니터링 소프트웨어를 개발하였다. 측정된 자력값은 띠통과 필터(notch filter)와 대역통과필터(band-pass filter)를 거쳐서 최종적으로 1Hz 데이터로 저장된다. 본 시스템 검증을 위해 자성체 반응을 확인하는 예비 실험이 먼저 수행되었고, 이후 철광산 두 곳에서 현장 실증을 실시하였다. 현장 실증으로 경기도 포천과 강원도 정선 지역에서 자체 개발한 드론 자력탐사 시스템과 한국지질자원연구원(KIGAM)이 제작한 무인비행선 자력탐사 시스템 결과와 비교하였다. 그 결과 예비 실험과 현장 실증을 통해 본 시스템은 야외 항공 자력탐사에 충분히 활용 가능함을 확인할 수 있었다. 향후 양질의 항공자력탐사 자료 획득을 위해 잡음을 최소화하는 필터 기능 및 기구 성능을 고도화하는 연구가 요구된다.

유동형 미세 열유속 센서의 설계 (Design of The Micro Fluidic Heat Flux Sensor)

  • 김정균;조성천;이선규
    • 한국정밀공학회지
    • /
    • 제26권11호
    • /
    • pp.138-145
    • /
    • 2009
  • A suspended membrane micro fluidic heat flux sensor that is able to measure the heat flow rate was designed and fabricated by a complementary-metal-oxide-semiconductor-compatible process. The combination of a thirty-junction gold and nickel thermoelectric sensor with an ultralow noise preamplifier, low pass filter, and lock-in amp has enabled the resolution of 50 nW power and provides the sensitivity of $11.4\;mV/{\mu}W$. The heater modulation method was used to eliminate low frequency noises from sensor output. It is measured with various heat flux fluid of DI-water to test as micro fluidic application. In order to estimate the heat generation of samples from the output measurement of a micro fluidic heat-flux sensor, a methodology for modeling and simulating electro-thermal behavior in the micro fluidic heat-flux sensor with integrated electronic circuit is presented and validated. The electro-thermal model was constructed by using system dynamics, particularly the bond graph. The electro-thermal system model in which the thermal and the electrical domain are coupled expresses the heat generation of samples converts thermal input to electrical output. The proposed electro-thermal system model shows good agreement with measured output voltage response in transient state and steady-state.

Ground-born vibration at multileveled train tunnel crossing

  • Moon, Hoon-Ki;Kim, Kang-Hyun;Kim, Ho-Jong;Shin, Jong-Ho
    • Structural Engineering and Mechanics
    • /
    • 제73권4호
    • /
    • pp.367-379
    • /
    • 2020
  • In recent railway projects where the railway connects between cities, newly planned tunnels are often located close to, or beneath an existing tunnel. Many claims and petitions have voiced public concern about the vibration and noise resulting from the situation. Vibrations and noises are engineering issues as well as environmental problems, and have become more important as people have become more concerned with their the quality of life. However, it is unlikely that the effects of vibration in situations where trains simultaneously pass a multileveled tunnel crossing have been appropriately considered in the phase of planning and design. This study investigates the superposition characteristic of ground-born vibrations from a multileveled tunnel crossing. The results from model tests and numerical analysis show that the ground-born vibration can be amplified by a maximum of about 30% compared to that resulting from the existing single tunnel. Numerical parametric study has also shown that the vibration amplification effect increases as the ground stiffness, the tunnel depth, and the distance between tunnels decrease.