• Title/Summary/Keyword: Particulate Matters

Search Result 441, Processing Time 0.027 seconds

Characteristics of Particulate Atmospheric Polycyclic Aromatic Hydrocarbons Pollution in Residential/Roadside Areas of Metropolitan Cities and a Background Area (대도시의 주거/도로변 지역 및 배경 지역의 대기 중 입자상 다환 방향족 탄화수소의 특성)

  • Jang, Jong-Dae;Shin, Seung-Ho;Jo, Wan-Kuen
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.861-869
    • /
    • 2010
  • The present study aims to evaluate the characteristics of atmospheric polycyclic aromatic hydrocarbons (PAHs) pollution in roadside and residential areas of two Korean metropolitan cities (Seoul and Incheon) and a background area (Seokmolee). This purpose was established by analyzing temporal and spacial concentration distribution of total and 7 individual PAHs, which were extracted from ambient particulate matters, and by utilizing a multivariate statistical method (principal component analysis, PCA) for the qualitative determination of potential PAH sources. Target PAHs included benzo(a)anthracene (BaA), benzo(a)pyrene (BaP), benzo(b)fluoranthene (BbF), benzo(k)fluoranthene (BkF), chrysene (Chr), dibenzo(a,h)anthracene (DahA), and indeno(1,2,3-cd)pyrene (IcdP). For all surveyed sites, the concentrations of total PAHs were higher in winter season than in other seasons. However, the concentrations of individual PAHs varied with surveyed sites. In both residential and roadside sites of Seoul and Incheon, BbF revealed the highest atmospheric levels. For all 7 target PAHs, the ambient concentrations were higher in Seoul and Incheon than in a background area (Seokmolee). In both residential and roadside areas, the concentrations of 4 target PAHs (BaA, BbF, BkF, DahA) were higher in Incheon than in Seoul. However, both the residential and roadside Chr concentrations were comparable in Seoul and Incheon. In addition, the residential IcdP concentrations were higher in Incheon than in Seoul, whereas the roadside concentrations were higher in Seoul. The roadside and residential BaP concentrations exhibited the reverse result to the IcdP concentrations. An PCA analysis suggested that atmospheric PAHs in both residential and roadside areas would be due to combined effects of several potential sources such as gasoline- and diesel-fueled vehicles, coal/oil combustion, and waste incineration.

The Correlation between Radon (Rn222) and Particulate Matters (PM10, PM2.5, PM1.0) in Subway Tunnel in Seoul.

  • Versoza, Michael;Park, Duckshin
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.87-95
    • /
    • 2017
  • Radon ($Rn^{222}$) is a radioactive gas and is found at high concentrations underground. Investigations were done in many years specifically on public transportations such as in the subway stations, concourses and platforms for these are located underground areas. This study correlates the $Rn^{222}$ concentrations with the Particulate Matter (PM) concentration for the gas could be attached or trapped inside these particles. It was done on the opening subway tunnel of Miasageori Station going to Mia Station (Line 4) last August 2016. Based on the result, the $Rn^{222}$ were more influenced on the mass ratio (%) of PM present in the air instead of its mass concentration (${\mu}g/m^3$). As the $PM_{10}$ mass ratio increases ($42.32{\pm}1.03%$) during morning rush-hours, radon starts to increase up to $0.97{\pm}0.03pCi/L$. But during the afternoon $Rn^{222}$ concentrations decreased while the composition were stable at $22.96{\pm}3.0%$, $39.04{\pm}0.6%$ and $38.01{\pm}0.3%$ in $PM_1$, $PM_{2.5}$ and $PM_{10}$ respectively. It was then assumed that it could be the composition of the morning hours of the station were influencing the concentration of the radon.

Efficient Anaerobic Digestion for Highly Concentrated Particulate Organic Wastewater (고농도 입자성 유기폐수의 고효율 혐기성 소화 공정)

  • Lee, Sungbum;Shin, Kyuchul;Kim, Huijoo;Kim, Hyunju;Choi, Changkyoo;Kim, Moonil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.2
    • /
    • pp.23-29
    • /
    • 2008
  • It has been mentioned that CSTR (Completely Stirred Tank Reactor) and UASB (Upflow Anaerobic Sludge Blanket) processes, the existing anaerobic processes, have problems in the treatment of highly concentrated particulate organic wastewater (HCPOW). Therefore, this paper discusses the treatment possibility of distillery wastewater which is a typical HCPOW using ADEPT (anaerobic Digestion Elutriated Phased Treatment) process. In the comparison of CSTR and ADEPT, ADEPT produced much higher gas than that of CSTR removing more organic matters and suspended solids in ADEPT process, ADEPT had no effect on the decrease in pH by volatile fatty acids and showed steady pH in spite of relatively short HRT. In the results of removal rate according to recycle ratios between 6Qin and 2Qin in ADEPT, 6Qin showed high removal rate during the operation time. Therefore it appears that ADEPT had an applicability for the treatment of distillery wastewater. ADEPT could be a economical process, due to the short HRT, the energy recovery by the methane production, and the utilization for carbon source of produced organic acid from the ADEPT-acid reactor.

  • PDF

Emission Characteristics of Fine Particles from Thermal Power Plants (화력발전소의 미세먼지 배출특성)

  • Park, Sooman;Lee, Gayoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.455-460
    • /
    • 2020
  • In order to identify the characteristics of fine particle emissions from thermal power plants, this study conducted measurement of the primary emission concentration of TPM, PM10 and PM2.5 according to Korea standard test method (ES 01301.1) and ISO 23210 method (KS I ISO 23210). Particulate matters were sampled in total 74 units of power plants such as 59 units of coal-fired power plants, 7 units of heavy oil power plants, 2 units of biomass power plant, and 6 units of liquid natural gas power plants. The average concentration of TPM, PM10, PM2.5 by fuel are 3.33 mg/m3, 3.01 mg/m3, 2.70 mg/m3 in coal-fired plant, 3.02 mg/m3, 2.99 mg/m3, 2.93 mg/m3 in heavy oil plant, 0.114 mg/m3, 0.046 mg/m3, 0.036 mg/m3 in LNG plant, respectively. These results of TPM, PM10 and PM2.5 were satisfied with the standards of fine dust emission allowance in all units of power plants, respectively. Also, this study evaluated the characteristics of fine particle emissions by conditions of power plants including generation sources, boiler types and operation years and calculated emission factors and then evaluated fine particle emissions by sources of electricity generation.

Emission Characteristics of Air Pollutants and Black Carbon from Wood-pellet Stove and Boiler (목재 펠릿 난로와 보일러 사용에 의한 대기오염물질과 블랙카본의 배출 특성)

  • Park, Sung Kyu;Lyu, Kun Jung;Kim, Daekeun;Kim, Dong Young;Jang, Young Kee;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.6 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • This study was carried out simulating domestic utilization conditions of a wood pellet stove and a wood pellet boiler in order to determine emission factors (EFs) of macro-pollutants, i.e., carbon monoxide, nitrogen oxides, sulfur oxides, ammonia, particulate matters (total suspended particulate, $PM_{10}$, $PM_{2.5}$, black carbon) and trace pollutants (i.e., ten different volatile organic compounds). The composite pollutants EFs for the pellet stove were: for TSP 4.58 g/kg, for $PM_{10}$ 3.35 g/kg, for $PM_{2.5}$ 2.48 g/kg, CO 119.23 g/kg, NO 14.40 g/kg, $SO_2$ 0.17 g/kg, TVOC 37.73 g/kg, $NH_3$ 0.02 g/kg and emissions were similar to the pellet boiler appliance: for TSP 4.73 g/kg, for $PM_{10}$ 3.41 g/kg, for $PM_{2.5}$ 2.63 g/kg, CO 161.51 g/kg, NO 13.67 g/kg, $SO_2$ 0.19 g/kg, TVOC 45.22 g/kg, $NH_3$ 0.02 g/kg.

Emission Characteristics of Air Pollutants and Black Carbon from Wood Stove and Boiler (화목 난로와 보일러 사용에 의한 대기오염물질과 블랙카본의 배출 특성)

  • Park, Sung Kyu;Choi, Sang Jin;Kim, Dae keun;Kim, Dong Young;Jang, Young Kee;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.6 no.1
    • /
    • pp.49-54
    • /
    • 2015
  • Manually fed firewood burning appliances, i.e., stove and boiler, were tested in order to determine emission factors (EFs) of macro-pollutants, i.e., carbon monoxide, nitrogen oxides, sulfur oxides, ammonia, particulate matters (total suspended particulate, $PM_{10}$, $PM_{2.5}$, black carbon) and trace pollutants (i.e., ten different volatile organic compounds). The composite pollutants EFs for the wood stove were: for TSP 15.45 g/kg, for $PM_{10}$ 6.53 g/kg, $PM_{2.5}$ 4.16 g/kg, CO 175.49 g/kg, NO 1.58 g/kg, $SO_2$ 0.15 g/kg, TVOC 48.02 g/kg, $NH_3$ 0.02 g/kg and emissions were similar to the wood boiler appliance: for TSP 12.23 g/kg, for $PM_{10}$ 5.84 g/kg, $PM_{2.5}$ 3.66 g/kg, CO 146.74 g/kg, NO 1.42 g/kg, $SO_2$ 0.15 g/kg, TVOC 47.78 g/kg, $NH_3$ 0.01 g/kg.

Contingent Valuation Survey on Changes in Citizens' Perception on Atmospheric Pollution in Seoul, Korea (조건부 가치 설문조사를 통한 대기 오염에 대한 서울 시민의 인식 변화 조사)

  • Hong, Je-Woo;Hong, Jinkyu;Kim, Junghwan
    • Atmosphere
    • /
    • v.29 no.2
    • /
    • pp.213-218
    • /
    • 2019
  • A valuation of air pollution is critical for relevant policy-making for the public and research direction. This study conducted a willingness-to-pay (WTP) survey using contingent valuation method (CVM) in Seoul Korea. In detail, this study puts an emphasis on its temporal changes referred on two surveys conducted in 2014 and 2019. In reference to the previous studies in 2002, our survey indicated that the public awareness of air pollution and interests on its sources and solutions increased noticeably. Our survey showed that WTP increased significantly from 2588 to 4827 and 8240 Korean Won $month^{-1}$ in 2002, 2014, and 2019, respectively. Moreover, the percentage of respondents to pay the WTP also increased from 48% to 68% and 79% in 2002, 2014, and 2019, respectively. Our analysis based on the number of Google search on particulate matters (PMs) strongly suggests that such the noticeable increases of the public attention to air pollution is well accorded with the moment of the announcement of a standard for ultra-fine particles and the start of PM prediction in late 2013. But the Google search rate grew about 16.7 times in 2009 compared to 2014, which is much larger than the growth rate of interest and WTP between 2014 and 2019. Our results shed light on policy decision for the right person in the right place on the right time in the era of air pollution.

Investigation on Generation and Emission of Particulate Matters and Ammonia from Mechanically-ventilated Layer House (강제환기식 산란계 사육시설의 PM, NH3 발생·배출 특성 조사)

  • Jang, Dong-Hwa;Yang, Ka-Young;Kwon, Kyeong-Seok;Kim, Jong-Bok;Ha, Tae-Hwan;Jang, Yu-Na
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.1
    • /
    • pp.99-110
    • /
    • 2022
  • In this study, the generation and emission characteristics of particulate matter and gaseous matter in a mechanically ventilated layer house were evaluated. Each concentration of PM10, PM2.5, inhalable dust, respirable dust, and NH3 was measured and compared with occupational limit considering seasons and respiratory disorder. CAPPS (Clean Air Policy Support System) of the Ministry of Environment proposes the emission factors of PM10, PM2.5, and NH3 for a layer houses however, emission factors are still calculated from foreign factors such as CONINAIR values. As a result, it is urgent to develop national emission factors for domestic layer house. Emission coefficients of the studied mechanically-ventilated layer house in a summer season were calculated as 0.052 kg/head/year for PM10, about 12% lower than that of CAPSS, and 0.0068±0.0038 kg/head/year for PM2.5, showing no significant difference. Emission factor of NH3 was calculated as 0.159±0.031 kg/head/year, about 51% lower than that of CAPSS.

Study on the characterization of dissolved organic matters in Nakdong River (낙동강의 용존 유기물질 특성에 관한 연구)

  • Heo, Seong-Nam;Park, Jeong-Min;Im, Tae-Hyo;Shin, Chan-Ki
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.13-26
    • /
    • 2007
  • Changes in the characteristics of dissolved organic matter was studied at selected stations in the Nakdong river basin using physical and chemical methods. Characteristics of dissolved organic matters were analysed and assessed. Production of disinfection byproducts were also investigated. 1. Result of relatedness study among each items of analyses showed that relatedness on BOD values were highest with cattle excrement treatment facilities where there is no synthetic organic materials and relatedness on $COD_{Mn}$ were highest at the mainstream Nakdong river. In case of $COD_{Cr}$ (which has more oxidative power than $COD_{Mn}$), the values were higher in the sidestreams indicating the higher content of recalcitrant compounds. The relatedness values for the $UV_{254}$ also showed higher values in the sidestreams and treatment facilities than mainstream indicating the presence of organic aromatic compounds. 2. Ratio of DOC on total organic carbon were higher in the mainstream which is attributable to the influent particulate organic materials produced by agricultural activities. The values were 10-15% higher in the mainstream compared with sidestreams. 3. Result of biodegradability test indicate that concentrations of recalcitrant DOC were higher in the sidestreams than in the mainstream. The values of recalcitrant DOC were higher with the forest stream indicating the effect of soil oriented humic substances. 4. Result of THM production test carried out at 10 stations in the Nakdong river show that $CHCl_3$ was detected with the highest value and the value was highest at Waekwan station.

Experimental Study on Particle Collection Efficiency of Axial-flow Cyclone in Air Handling Unit (공기조화기 장착용 축상유입식 싸이클론의 입자제거효율에 대한 실험적 연구)

  • Kim, Se-Young;Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jin-Ho;Kim, Myung-Joon;Kim, Tae-Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.3
    • /
    • pp.272-280
    • /
    • 2011
  • A novel particle removal system for air handling unit (AHU) of subway station was evaluated experimentally. The novel system was designed in order to minimize the maintenance cost by applying axial-flow cyclones. The system consists of multiple cyclone units and dust trap. Based on our previous numerical study, it was found to be effective for removal $1\sim10{\mu}m$ sized dust particles. In this study, we manufactured the mock-up model and evaluated the model experimentally. Liquid and solid test particles were generated for evaluating collection efficiency of the system and the pressure drop was monitored. The collection efficiency was varied from 41.2% to 85.9% with increasing the sizes of particle from 1 to $6.5{\mu}m$ by particle count ratio of inlet and outlet. The pressure drop was maintained constant less than $20mmH_2O$. In addition, the collection efficiency was estimated by total mass for solid test particles. It was found that the collection efficiency was 65.7% by particle mass ratio of inlet and outlet. It shows that present system can replace current pre-filters used in subway HVAC system for removing particulate matters with minimal operational cost.