• Title/Summary/Keyword: Particle size measurement

Search Result 441, Processing Time 0.024 seconds

A Numerical Study of Heat and Mass Transfer Model of LII for Nanoscale Soot Particles (나노크기의 매연입자에 대한 LII의 열-물질 전달 모델에 관한 수치적 연구)

  • Kim, Gyu-Bo;Shim, Jae-Young;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.7 s.262
    • /
    • pp.596-603
    • /
    • 2007
  • As increasing interest for soot emission. etc in combustion systems, various studies are being carried out for the reduction and measurement techniques of soot. Especially, laser induced incandescence is the useful measurement technique which has distinguished spatial and temporal resolution for primary particle size, volume fraction and aggregated particle size etc. Time resolved laser induced incandescence is the technique for measuring primary particle size that is decided to solve the signal decay rate which is related to the cooling behavior of heated particle by pulsed laser. The cooling behavior of heated particle is able to represent the heat and mass transfer model which are involved constants of soot property for surround gas temperature on the our previous work. In this study, it is applied to the time-dependence thermodynamic properties for soot temperature instead of constants of soot property for surround gas temperature and compared two different model results.

Measurement and Analysis of Visibility lmpairment during June, 1994 in Seoul (1994년 6월 서울지역 시정장애의 측정 및 분석)

  • 백남준;이종훈;김용표;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.407-419
    • /
    • 1996
  • Characteristics of visual air quality in Seoul have been investigated between June 13 and 21, 1994. Optical properties (extinction coefficient and particle scattering coefficient), meteorological parameters (relative humidity, temperature, wind speed, wind direction, and cloud cover), particle characteristics (mass size distribution, components) were measured and analyzed. During measurement periods, northwest wind with less than 2m/sec of wind speed deteriorates visibility. Effects of relative humidity are though to be not a direct factor which influence to visibility through the size change due to hygroscopic species in aerosol. During the smoggy period both the aerosol mass concentration and fine particle fraction of the size distribution are increased compared to the clear period. Sulfate, organic carbon, and elemental carbon in aerosol are the major species in determining the occurrence and severity of a smog in Seoul.

  • PDF

Effect of DPF Regeneration on the Nano Particle Emission of Diesel Passenger Vehicle (DPF 재생이 경유승용차의 미세입자 배출에 미치는 영향 연구)

  • Kwon, Sang-Il;Park, Yong-Hee;Kim, Jong-Choon;Lee, Chang-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.153-159
    • /
    • 2007
  • Nano-Particles are influenced on the environmental protection and human health. The relationships between transient vehicle operation and nano-particle emissions are not well-known, especially for diesel passenger vehicles with DPF. In this study, a diesel passenger vehicle was measured on condition of DPF regeneration and no regeneration on a chassis dynamometer test bench. The particulate matter (PM) emission from this vehicle was measured by its number, size and mass measurement. The mass of the total PM was evaluated with the standard gravimetric measurement method while the total number and size concentrations were measured on a NEDC driving cycle using Condensation Particle Counter (CPC) and EEPS. Total number concentration by CPC was $1.5{\times}10^{1l}N/km$, which was 20% of result by EEPS. This means about 80% of total particle emission is consist of volatile and small-sized particles(<22nm). During regeneration, particle emission was $6.2{\times}10^{12}N/km$, was emitted 400 times compared with the emission before regeneration. As for the particle size of $22{\sim}100nm$ was emitted mainly, showing peak value of near 40nm in size. This means regeneration decreased the mean size of particles. Regarding regeneration, PM showed no change while the particle number showed about 6 times difference between before and after regeneration. It seems that the regeneration influences on particle number emissions are related to DPF-fill state and filtration efficiency.

A Study on Particle Diffusion to Develop Faraday Cup Array of Particle Beam Mass Spectrometer System (Faraday cup array 개발을 위한 Particle Beam Mass Spectrometer 시스템 내에서의 입자 확산 연구)

  • Mun, Ji-Hun;Shin, Yong-Hyun;Kim, Tae-Sung;Kang, Sang-Woo
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • The Faraday cup electrode of different size has been developed and evaluated to investigate the diffusion effect of particles by Brownian motion in a particle beam mass spectrometer(PBMS). Particles which focused and accelerated by aerodynamic lens are charged to saturation in an electron beam, and then deflected electrostatically into a Faraday cup detector for measurement of the particle current. The concentration of particles is converted from currents detected by Faraday cup. Measurements of particle current as a function of deflection voltage are combined with measured relationships between particle velocity and diameter, charge and diameter, and mass and diameter, to determine the particle size distribution. The particle currents were measured using 5, 10, 20, 40 mm sized Faraday cup that can be move to one direction by motion shaft. The current difference for each sizes as a function of position was compared to figure out diffusion effect during transport. Polystyrene latex(PSL) 100, 200 nm sized standard particles were used for evaluation. The measurement using 5 mm sized Faraday cup has the highest resolution in a diffusion distance and the smaller particles had widely diffused.

Studies on the relationship of the preparation and the particle size of the precipitated calcium carbonate (침강탄산칼슘제조건과 그 입자도에 관한 연구)

  • 나운룡
    • YAKHAK HOEJI
    • /
    • v.12 no.3_4
    • /
    • pp.41-49
    • /
    • 1968
  • The optimum reaction conditions for the preparation of the precipitated calcium carbonate of an average particle size of 0.05.mu. in diameter was set in which the Box-Wilson Plan was applied. The reaction conditions are as follows; 1) concentration of milk of lime; 6.56% w/w 2) temperature; 14.24.deg. C #) velocity of carbon dioxide introducing; 1.95l/min. The crystal form was found that of calcite in X-ray diffraction analysis. The particle size was determined by the sedimentation volume measurement. The shape was identified by the elctron micro-diffraction pattern and the electron microscopic photographs.

  • PDF

Analysis of Measuring Error for Particle Size Analysis by Laser Diffraction Spectrometer (입자크기분석을 위한 레이저회절 분광계의 측정오차 분석)

  • Ha, Sang-An;Son, Heui-Jeong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.713-722
    • /
    • 2000
  • This study analysed error of measurement and reproducibility for particle size analysis by the laser diffraction spectrometer. Laser diffraction spectrometers has become a very important method of particle size analysis. This measuring method has the advantage of simple operation, good reproducibility and rapid analysis. A feeding and dispersing system have been developed, which allows mass throughputs between 0.1~23 g/min in flowing air and 1.4~35% in flowing liquid. It has been used as a feeder unit for wet and dry particle size analysis from diffraction patterns. Relevant parameters, such as particle shape, particle size, dispersion, flow rate, concentration were analysed for measuring error. And system parameters of instruments for measurement of dynamic processes, eg, measuring time, focal plane, injection pressure drop and dispersion effect by the ultrasonic and mixing of preliminary treatment, were also discussed.

  • PDF

The Effect of Water Droplets on the Nano Particle Size Distribution using the SMPS System (SMPS 시스템에서 용매(물)가 나노입도측정결과에 미치는 영향)

  • Hwangbo, Seon-Ae;Chu, Min-Cheol
    • Journal of Powder Materials
    • /
    • v.20 no.2
    • /
    • pp.129-133
    • /
    • 2013
  • In this paper we have studied the effect of water droplet size on nano-particle size distribution using SMPS(Scanning Mobility Particle Sizer)system. It can be seen that the unknown peak at >100 nm was caused by water droplets which did not dry completely when DI water was used as a solvent in the SMPS system. Therefore, it is important to dry water droplets generated from atomizer in the SMPS system when measuring the particle size distribution using less than 100 nm nano-particles in diameter. From this study, It can be concluded that the napion was a useful material as dryer ones and using EAG(Electro Aerosol Generator) as a particle generator was the most effective in reducing the effect of water droplets.

Manufacturing Process of Translucent Microemulsion and Its Stability (Translucent Microemulsion의 제조 공정과 안정성)

  • Bae, Duck-Hwan;Shin, Jae-Sup
    • Journal of the Korean Applied Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.167-173
    • /
    • 2000
  • The process variables for the manufacture of translucent microemulsion prepared with 2-octyl dodecanol, 12-hydroxy stearic acid cholesteryl , POE(40)HCO and 1,3-butandiol were examined initially (primary emulsion) and following aging for three months. The techniques empolyed in this study were particle size, turbidity, interfacial tension and microfluidizer. Particle size analysis and turbidity measurement to evaluate the emulsion stability were used. It was concluded that the process of the emulsification was an important indicator of the stability of the translucent microemulsion. From the particle size and and turbidity measurement of translucent microemulsion, adding the surfactant to the oil phase before the emulsification was found to be the most important factor for the stability of emulsions. We found that interfacial tension of the adding the surfactant to the oil phase is lower than that of the adding the surfactant to aqueous phase. In spite of hydrophilic surfactant, adding the surfactant to aqueous phase produced inferior emulsion to that to oil phase.

Turbidimetric Measurement for On-line Monitoring of SiO2 Particles

  • Kim, In-Sook;Kim, Yang-Sun;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.801-805
    • /
    • 2004
  • In this work, the fundamental study of on-line monitoring of $SiO_2$ particles in the size range of 40 nm to 725 nm was carried out using turbidimetry. The size of particle was measured using a field emission scanning electron microscope (FE-SEM). The factors affecting on the turbidity were discussed, for example, wavelength, size, and concentration. In order to observe the dependence of turbidity on the wavelength, a turbidimetric system equipped with charged coupled detector (CCD) was built. The shape of the transmitted peak was changed and the peak maximum was shifted to the red when the concentration of particle was increased. This result indicates that the turbidity is related to the wavelength, which corresponds to the characteristic of the Mie extinction coefficient, Q, that is a function of not only particle diameter and refractive index but also wavelength. It is clear that a linear calibration curve for each particle in different size can be obtained at an optimized wavelength.

Measurement Technique of Particle Sizing in Spay Flow (분무 유동의 입경 계측 기법에 관한 연구)

  • Yang, Chang-Jo;Kim, Jeong-Hwan;Oh, Jong-Hwan;Kim, Mann-Eung;Lee, Young-Ho
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.534-539
    • /
    • 2005
  • Particle image analyzer for measuring droplet size has been developed. Image processing technique was used with relaxation method. The morphological method based on partial curvature information of pre-processed images was adopted for recognition and separation of overlapped particles. The measurement results show that the present method may be reliable for the analysis of the size and distribution of droplets produced by water mist spay flow.

  • PDF