• 제목/요약/키워드: Particle counts

검색결과 45건 처리시간 0.024초

광학 입자 계수기의 응답특성 및 오계수에 관한 연구 (A Study of Response Characteristics and False Counts in Optical Particle Counter)

  • 안강호;이재헌
    • 대한기계학회논문집
    • /
    • 제16권3호
    • /
    • pp.547-554
    • /
    • 1992
  • 본 연구에서는 Climet사의 백색광원 OPC인 CI226와 PMS사의 laser 광원 OPC인 LAS-X 및 HS-LAS의 응답특성을 측정하여 제작사가 제시한 응답특성과 비교하여 그 정 확성을 논하였으며 아울러 고유량(high flow rate) Clean Room용 OPC인 Climet CI- 7300, Met One 200, Hiac/Royco5120 등 3가지 장치에 관한 오계수의 원인을 박히고자 하였다.

고청정 작업환경에 적합한 방진복 디자인 개발 -파티클 발생량을 중심으로- (Design and Manufacturing of Clean Room Garments Required at Ultra Clean Environment - Based on comparative analysis of Particle Release-)

  • 박상희;송명견
    • 한국의류학회지
    • /
    • 제25권6호
    • /
    • pp.1037-1045
    • /
    • 2001
  • This research is done to design and manufacture prototype clean room garments to improve the product yield of the clean room processing. To assist the research, other papers and references on the same subject were collected for analysis. Also the researcher made interviews with the workers at the clean room. The prototype garments made for this project was compared against the commercially available clean room garments used in the industry. A set of test was conducted to measure particle release from the garments. The prototype clean room garments was manufactured after having considered all the aspects stated above, and tested for the level of particle release. The test subjects performed 4 different movements(marching, arms stretch, squat and rise, and jogging) while wearing the prototype garments and commercially available clean room garments. Particle counts produced by each movement were measured. The data collected was statistically analyzed. The followings are the result of the test. 1) Overall, the prototype garments yielded less particle release.(p<0.001) 2) It showed greatest difference of particle counts for jogging(p<0.001) and squat and rise(p<0.001). In the arms stretch test. the prototype garments was also more effective in controling the particle, however, in the marching test. no significant difference was detected. 3) The prototype garments had less particle release in upper(p<0.001), middle(p< 0.001), and lower level(p<0.01) than the commercially available clean room garments. Manufacturing a new fabric for the clean room processing is important, but this research proves that the design of the clean room garments also determines the efficiency garments in the particle control. Therefore the same fabric can perform differently according to how it is designed. Improving the design will also improve the 7article control and reduce the cost of research. Eventually, the manufacturers will increase the product yield.

  • PDF

미규제 수질인자를 이용한 정수공정의 효율성 평가 (Evaluation of Treatment Efficiency using non-Control Indicator in Drinking Water Treatment Process)

  • 이재영;강미아
    • 지질공학
    • /
    • 제16권2호
    • /
    • pp.153-159
    • /
    • 2006
  • 수질오염이 심각해지면서 수자원의 이용을 어렵게 하며 수자원의 관리를 위해 사용되는 시간적 기술적 경제적 부하도 증대시키고 있다. 그러므로 본 논문에서는 간단하고 신속하게 수질을 파악 할 수 있는 미규제 수질인자($E_{260}$과 입자수)를 도입하여 정수공정의 효율성을 평가하고자 하였다. 탁도저감을 목적으로 주입하는 알루미늄에 의해 용존성 알루미늄의 잔존량이 증가하는 경향이 있으므로 탁도 모니터링만으로는 안전한 수질을 기대하기가 어려움을 명확히 알 수 있었으며, 잔존알루미늄의 농도를 모니터링 하는 대신 간단 신속하게 분석할 수 있는 $E_{260}$인자를 이용할 수 있음을 밝혔다. 또한 탁도 뿐만 아니라 용존성 비소화합물의 모니터링에도 $E_{260}$은 효율적으로 사용되었다. 수처리공정의 효율을 개선하기 위해 수처리제의 교환을 고려할 때에도 탁도 자료만으로는 질적인 개선정도를 평가하기 어려웠으나, 수중의 입자를 계수함으로써 재선정도의 평가가 용이해져 적절한 수처리제의 선택을 가능하게 하므로 수질개선과 경제적 절약을 모두 달성하게 하였다. 따라서 효율적인 정수처리 뿐만 아니라 수자원의 관리 측면에서도 이들 인자는 매우 유용하게 사용될 수 있을 것으로 기대된다.

다중이용시설 및 학교 교사내 실내공기중 섬유상 입자의 농도 특성 (Characterizations of Airborne Fiber Particle Concentrations in Public Facilities and Schools)

  • 박정호;서정민
    • 한국환경과학회지
    • /
    • 제19권4호
    • /
    • pp.509-516
    • /
    • 2010
  • This study was investigated the characteristics of indoor air concentration of fiber particles in 30 public facilities and 245 schools by PCM (phase contrast microscopy). Also SEM/EDX (scanning electron microscope / energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber and to classify asbestos and non-asbestos of fiber particles. The airborne concentrations of fiber particles were $0.0009\pm0.0009$ counts/mL in public facilities and $0.0012\pm0.0006$ counts/mL in schools by PCM. All the samples were satisfied with the IAQ (indoor air quality) level of 0.01 counts/mL. In classification of 4 type shapes, over 80% of the fiber particles were identified as single fiber type. And this study analysed airborne fiber particles in 4 sites for identifying asbestos of by SEM/EDX. The asbestos fibers in most samples could not be found.

Extended Neutral Particle Analyzer System for the KSTAR

  • Kim, Sun-Ho;Gu, Dong-Jin;Park, Min;Ahn, Chan-Yong;Wang, Son-Jong;Kim, Sung-Kyu
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.272-272
    • /
    • 2012
  • Additional neutral particle analyzer has been installed to investigate the variation of fast ion tails with regard to the line of sight during 2012 KSTAR campaign. The system has the same photo-diode particle detector as previous system [1]. Both newly installed system and previous system modifield for 2012 campaign have two channels. One has a particle stopper transparent to hard X-ray, the other has no one. It will be used to separate the hard X-ray component from total hard X-ray and fast neutral counts. It is expected to measure fast ion tails more clearly through this extended system. A detailed system and calibration result will be presented in the conference.

  • PDF

Effects of hydrodynamics and coagulant doses on particle aggregation during a rapid mixing

  • Park, Sang-Min;Heo, Tae-Young;Park, Jun-Gyu;Jun, Hang-Bae
    • Environmental Engineering Research
    • /
    • 제21권4호
    • /
    • pp.365-372
    • /
    • 2016
  • The effects of hydrodynamics and alum dose on particle growth were investigated by monitoring particle counts in a rapid mixing process. Experiments were performed to measure the particle growth and breakup under various conditions. The rapid mixing scheme consisted of the following operating parameters: Velocity gradient (G) ($200-300s^{-1}$), alum dose (10-50 mg/L) and mixing time (30-180 s). The Poisson regression model was applied to assess the effects of the doses and velocity gradient with mixing time. The mechanism for the growth and breakup of particles was elucidated. An increase in alum dose was found to accelerate the particle count reduction. The particle count at a G value of $200s^{-1}$ decreased more rapidly than those at $300s^{-1}$. The growth and breakup of larger particles were more clearly observed at higher alum doses. Variations of particles due to aggregation and breakup of micro-flocs in rapid mixing step were interactively affected by G, mixing time and alum dose. Micro-flocculation played an important role in a rapid mixing process.

Development, validation and implementation of multiple radioactive particle tracking technique

  • Mehul S. Vesvikar;Thaar M. Aljuwaya;Mahmoud M. Taha;Muthanna H. Al-Dahhan
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4213-4227
    • /
    • 2023
  • Computer Automated Radioactive Particle Tracking (CARPT) technique has been successfully utilized to measure the velocity profiles and mixing parameters in different multiphase flow systems where a single radioactive tracer is used to track the tagged phase. However, many industrial processes use a wide range of particles with different physical properties where solid particles could vary in size, shape and density. For application in such systems, the capability of current single tracer CARPT can be advanced to track more than one particle simultaneously. Tracking multiple particles will thus enable to track the motion of particles of different size shape and density, determine segregation of particles and probing particle interactions. In this work, a newly developed Multiple Radioactive Particle Tracking technique (M-RPT) used to track two different radioactive tracers is demonstrated. The M-RPT electronics was developed that can differentiate between gamma counts obtained from the different radioactive tracers on the basis of their gamma energy peak. The M-RPT technique was validated by tracking two stationary and moving particles (Sc-46 and Co-60) simultaneously. Finally, M-RPT was successfully implemented to track two phases, solid and liquid, simultaneously in three phase slurry bubble column reactors.

Chemical Properties of the Individual Asian Dust Particles Clarified by Micro-PIXE Analytical System

  • Ma, Chang-Jin;Kang, Gong-Unn;Kasahara, Mikio;Tohno, Susumu
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권3호
    • /
    • pp.154-161
    • /
    • 2014
  • The present study was undertaken to evaluate the chemical characteristics of Asian dust (hereafter called "AD") particles with the aid of the most advanced micro-PIXE (Particle-induced X-ray emission) analytical technique. To this end, size-selected particles were sampled on a rural peninsula of Korea (Byunsan, 35.37N; 126.27E) during AD and non-AD periods in 2004. The coarse particle (> $2{\mu}m$) number density during an AD event were 170 times higher than those of the non-AD counterpart. The average net-count of silica in individual particles collected on AD event was roughly 11 times higher than that of non-AD counterpart. The X-ray net-counts of trace elements (Zn, Co, Mn, and V) were also considerably high in AD relative to the non-AD day. Particle classification based on the inter ratio analysis of elemental net-count suggests that a large portion of the coarse particles collected during AD event underwent chemical transformation to a certain degree. The visual interpretation of micro-PIXE elemental maps and elemental localization data in and/or on individual AD particles clarified the internal mixture of AD particles with sea-salt and artificial metallic particles.

Physicochemical Properties of Indoor Particulate Matter Collected on Subway Platforms in Japan

  • Ma, Chang-Jin;Matuyama, Sigeo;Sera, Koichiro;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권2호
    • /
    • pp.73-82
    • /
    • 2012
  • This study was aimed to thoroughly estimate the characteristics of indoor particulate matter (PM) collected on subway platforms by the cooperative approach of semi-bulk and single particle analyses. The size-resolved PM and its number concentration were measured on the platform in a heavily traveled subway station in Fukuoka, Japan. Particle Induced X-ray Emission (PIXE) and micro-PIXE techniques were applied to the chemical analyses of semi-bulk and single particle, respectively. There was the close resemblance of timely fluctuation between PM number concentration and train service on the third basement floor (B3F) platform compared to the second basement floor (B2F) and its maximum level was marked in rush hour. Higher number counts in large particles ($>1{\mu}m$) and lower number counts in fine particles ($<1{\mu}m$) were shown on the platform compared to an above ground. PM2.5 accounted for 58.2% and 38.2 % of TSP on B3F and on B2F, respectively. The elements that were ranked at high concentration in size-resolved semi-bulk PM were Fe, Si, Ca, S, and Na. The major elements tending to have more elevated levels on B3F than B2F were Fe (4.4 times), Ca (17.3 times), and Si (46.4 times). Although concentrations were very low, Cr ($11.9ng\;m^{-3}$ on B3F, $2.4ng\;m^{-3}$ on B2F), Mn ($3.4ng\;m^{-3}$ on B3F, $0.9ng\;m^{-3}$ on B2F), and Pb ($0.6ng\;m^{-3}$ on B3F, $1.6ng\;m^{-3}$ on B2F) were detected from PM2.5. Individual PM was nearly all enriched in Fe with Si and Ca. Classifying and source profiling of the individual particles by elemental maps and particle morphology were tried and particles were presumably divided into four groups (i.e., train/rail friction, train-rail sparking, ballast/abrasive, and cement).

PIXE 분석에 의한 대기에어로졸의 원소분석 -표준시료의 작성 및 정량화- (PIXE Analysis of Aerosol Particles - Preparation of Standard Samples and Calibration Test -)

  • 崔琴簒
    • 한국대기환경학회지
    • /
    • 제7권2호
    • /
    • pp.114-118
    • /
    • 1991
  • Particle Induce X-Ray Emission (PIXE) analysis is one of the most useful methods which can determine the elemental concentration of aerosol particles in nano-gram range. The main purpose of this paper is to establish the measurement system and the procedure of PIXE analysis. The standard samples were prepared to calibrate the PIXE analysis by three different techniques. The linear relationships between the peak counts from PIXE spectra and the mass density from RBS spectra were obtained for each standardized element under the applied measurment geometry and conditions. The sensitivity curves for PIXE analysis were determined from these relationships.

  • PDF