Abstract
This study was investigated the characteristics of indoor air concentration of fiber particles in 30 public facilities and 245 schools by PCM (phase contrast microscopy). Also SEM/EDX (scanning electron microscope / energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber and to classify asbestos and non-asbestos of fiber particles. The airborne concentrations of fiber particles were $0.0009\pm0.0009$ counts/mL in public facilities and $0.0012\pm0.0006$ counts/mL in schools by PCM. All the samples were satisfied with the IAQ (indoor air quality) level of 0.01 counts/mL. In classification of 4 type shapes, over 80% of the fiber particles were identified as single fiber type. And this study analysed airborne fiber particles in 4 sites for identifying asbestos of by SEM/EDX. The asbestos fibers in most samples could not be found.
Keywords
Indoor air; Fiber particle; Asbestos; PCM; SEM/EDX;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 함승헌, 황성호, 윤충식, 박동욱, 2009, 석면분석방법에 대한 고찰, 한국산업위생학회지, 19(3), 213-232.
2 황진연, 2009, 부산지역 다중이용시설의 석면사용에 대한 환경영향조사 및 개선방안, 부산지역환경기술개발센터, 최종연구보고서 08-2-70-72-1.
3 환경부, 2004a, 다중이용시설등의 실내공기질 관리법 시행규칙.
4 환경부, 2004b, 실내공기질 공정시험방법, 환경부 고시 제2004-80호.
5 환경부, 2009, 석면관리 총람, 1-19.
6 環境省, 2007, アスベストモニタリグマニュアル, 第3版.
7 International Agency for Research on Cancer (IARC), 1973, IARC Monographs on the Evaluation of Carcinogenic Risks to Humans Vol. 2 Some Inorganic and Organometallic Compounds Asbestos, IARC, 17-47.
8 Robert, L. V., 2006, Worldwide Asbestos Supply and Consumption Trends from1900 through 2003, U.S. Department of the Interior, U.S. Geological Survey, Circular 1298.
9 Shinji, K., Norio, K., 2008, Adverse Health Effects among Residents who Lived near Asbestos Industries, Earozoru Kenkyu, 23(1), 5-9.
10 강동묵, 2009, 환경성 석면노출의 건강영향, 한국환경보건학회지, 35(2), 71-77.   DOI
11 관계부처합동, 2010, 2010년도 석면관리 종합대책 세부 추진계획.
12 교육과학기술부, 2009, 학교석면 실태조사 및 관리 매뉴얼.
13 김윤신, 이철민, 박원석, 문정숙, 엽무종, 이태형, 2003, 건물의 실내공기 중 석면분포 특성, 한국대기환경학회 2003 춘계학술대회 논문집, 35, 427-428.
14 노동부, 2007, 산업안전보건법 제37조 및 동법시행령 제29조.
15 석면안전관리센터, 2009, http://info-asbestos.org/.
16 노영만, 박화미, 이철민, 김윤신, 이상운, 석미희, 정춘화, 2007, 일부 공공 및 학교시설에서의 석면 분포특성 조사, 한국실내환경학회지, 4(3), 184-193.
17 박정호, 서정민, 2005, 대기 점오염원에서 배출되는 개별 입자상물질의 물리화학적 특성, 한국환경과학회지, 14(8), 761-770.
18 박정호, 정혜미, 양수명, 정성진, 김명종, 서정민, 2007, 다중이용시설에서 발생되는 휘발성유기화합물(VOCs) 의 주요 구성성분, 한국환경과학회 봄학술발표회지, 16(1), 95-96.
19 안종주, 1989, 석면공해-조용한 시한폭탄, 동화기술.
20 유성환, 1993, 건축재료에서 발생되는 석면입자의 특성 연구, 한국대기보전학회지, 9(3), 191-199.
21 유성환, 김현욱, 1996, 전자현미경을 이용한 건물내 비고형 표면자재의 석면 오염 및 기중 석면농도 특성조사, 한국산업위생학회지, 6(2), 165-175.
22 정헌준, 백승화, 김종헌, 2002, 대전지역 지하상가에서의 석면농도에 관한 연구, 환경관리학회지, 8(2), 207-215.
23 최영아, 이태정, 김동술, 2007, SEM/EDX를 이용한 석면 및 비석면의 오염원분류표 개발, 한국대기환경학회지, 23(6), 718-726.
24 하권철, 2004, 경남지역 지하생활공간 중 석면 및 라돈의 농도 분포 특성, 한국산업위생학회지, 14(3), 319-324.