• Title/Summary/Keyword: Particle Impingement Erosion

Search Result 11, Processing Time 0.02 seconds

An Experimental Investigation of Particle Impingement Erosion in Hydraulic Systems (유압시스템의 입자 침해 침식의 실험적 고찰)

  • 이재천;김성훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.2
    • /
    • pp.117-122
    • /
    • 2002
  • This study assesses the wear process of particle impingement erosion which is a major source of erosion among fluid power components. First, Bitter's theory was modified to simplify engineering calculations. Second, actual experiments were conducted to validate the modified equation. And the effect of concentration and size distribution of impinging particles was tested. Little deviation from the prediction of the modified equation was observed. To develop complete analytical approach to the erosion mechanism, further experimental data are required to establish a correlation with other engineering parameters.

An Experimental Investigation of Particle Impingement Erosion in Hydraulic System (유압시스템의 입자 침해 침식의 실험적 고찰)

  • 이재천
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.15-21
    • /
    • 2001
  • This study assesses the wear process of particle impingement erosion which is a major source of erosion among fluid power components. First, Bitter's theory was modified to simplify engineering calculations. Second, actual experiments were conducted to validate the modified equation. And the effect of concentration and size distribution of impinging particles was tested. Little deviation from the prediction of the modified equation was observed. To develop an analytical approach to the erosion mechanism, further experimental data are required to establish a correlation with other engineering parameters.

  • PDF

Effect of Sealing Treatment on Solid Particle Impingement Erosion of Al-Zn-Zr Thermal Spray Coating Layer (Al-Zn-Zr 용사코팅층의 고체입자 충돌 침식특성에 미치는 봉공처리의 영향)

  • Heo, Ho-Seong;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.68-76
    • /
    • 2022
  • Several technologies are employed to protect substrates from corrosion and erosion damage. In particular, arc thermal spray coating technology is widely used as anti-corrosive technology for steel and concrete structures and is applied to offshore plants and petrochemical and drilling facilities. In this investigation, solid particle impingement erosion experiments were performed on an arc thermal spraying-coated specimen using 85% Al-14% Zn-1% Zr wire rod in KR-RA steel. This study investigated the effect of fluorosilicone sealing on the erosion resistance characteristics of the thermal spray coating layer. The erosion rates of the thermal spray-coated and sealed specimens were 4.1×10-4 and 8.5×10-4, respectively. At the beginning of the experiment, the fluorosilicone sealant was almost destroyed by the impact of the solid particles. The destruction time for the coating layer was 10 minutes for the thermal spray-coated specimen and 13 minutes for the sealed specimens, indicating that the sealed specimens had better erosion resistance characteristics to solid particle impingement.

Study on Erosion of Carbon Fiber Reinforced Plastic Composite (탄소섬유강화복합재료의 마식에 관한 연구)

  • Kim, Am-Kee;Kim, Il-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.291-297
    • /
    • 2008
  • The solid particle erosion behaviour of unidirectional carbon fiber reinforced plastic (CFRP) composites was investigated. The erosive wear of these composites was evaluated at different impingement angles ($30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $90^{\circ}$), different impact velocities (40, 55, 60, 70m/s) and at three different fiber orientations ($0^{\circ}$, $45^{\circ}$, $90^{\circ}$). The erodent was SiC sand with the size $50-100{\mu}m$ of irregula. shapes. The result showed ductile erosion behaviour with maximum erosion rate at $30^{\circ}$ impingement angle. The fiber orientations had a significant influence on erosion. The erosion rate was strongly dependent on impact velocity which followed power law $E{\propto}\;V^n$. Based on impact velocity (V), impact angle (${\alpha}$) and fiber orientation angle (${\beta}$), a method was proposed to predict the erosion rate of unidirectional fiber reinforced composites.

Development of Inspection Methodology for a Nuclear Piping Wall Thinning Caused by Erosion Using Ultrasonic B-Scan Measurement Device (B-Scan 초음파 측정장비를 이용한 원전 배관 침식손상 검사법 개발)

  • Lee, Dae Young;Suh, Heok Ki;Hwang, Kyeong Mo
    • Corrosion Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.89-95
    • /
    • 2012
  • U.S. Electric Power Research Institute (EPRI) has developed CHECWORKS program and applied it to power plant piping lines since some lines were ruptured by flow-accelerated corrosion (FAC) in 1978. Nowadays the CHECWORKS program has been used to manage pipe wall thinning phenomena caused by FAC. However, various erosion mechanisms can occur in carbon-steel piping. Most common forms of erosion are cavitation, flashing, liquid droplet impingement erosion (LDIE), and Solid Particle Erosion (SPE). Those erosion mechanisms cause pipe wall thinning, leaking, rupturing, and even result in unplanned shutdowns of utilities. Especially, in two phase condition, LDIE damages a wide scope of plant pipelines. Furthermore, LDIE is the major culprit to cause such as power runback by pipe leaking. This paper describes the methodologies that manage wall thinning and also predict LDIE wall thinning area. For this study, current properties of two-phase condition are investigated and LDIE areas are selected. The areas are checked by B-Scan method to detect the effect of wall thinning phenomena.

Evaluation of Liquid Droplet Impingement Erosion through Prediction Model and Experiment (예측모델 및 실험을 통한 액적충돌침식 손상 평가)

  • Yun, Hun;Hwang, Kyeong-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1105-1110
    • /
    • 2011
  • Flow-accelerated corrosion (FAC) is a well-known phenomenon that may occur in piping and components. Most nuclear power plants have carbon-steel-pipe wall-thinning management programs in place to control FAC. However, various other erosion mechanisms may also occur in carbon-steel piping. The most common forms of erosion encountered (cavitation, flashing, Liquid Droplet Impingement Erosion (LDIE), and Solid Particle Erosion (SPE)), have caused wall thinning, leaks, and ruptures, and have resulted in unplanned shutdowns in utilities. In particular, the damage caused by LDIE is difficult to predict, and there has been no effort to protect piping from erosive damage. This paper presents an evaluation method for LDIE. It also includes the calculation results from prediction models, a review of the experimental results, and a comparison between the UT data in the damaged components and the results of the calculations and experiments.

Solid Particle Erosion of Plasma-Sprayed Coatings (플라즈마 용사시킨 Carbide Coating층의 공상입자 Erosion 특성에 관한 연구)

  • 전승범;남승훈;김종집;이주진
    • Journal of the Korean institute of surface engineering
    • /
    • v.23 no.2
    • /
    • pp.11-17
    • /
    • 1990
  • The erosion characteristice of plasma-sprayed tungsten carbide chromium carbide coatings were investigated. Erosion tests were perfomed at room temperature by using Al2O3 and SiC particles accleerated in air stream. Weight losses of the coatings were measured over a range of paricle velocities and impingement angle. It was found that, for both of this coatings, the maximum erosion occurrd at a normal angle of impact, and the erosion rate at this impact angle was a power function of pparticle velocity. The values of the velocty emponent were between 3.07 and 3.50 Erosion value of chromium carbide coating was higher than that of tungsten carbide coating.

  • PDF

Comparison of Wall Thinning Analysis Results between CHECWORKS and ToSPACE (CHECWORKS와 ToSPACE 프로그램의 배관감육 해석결과 비교)

  • Hwang, Kyeongmo;Yun, Hun;Seo, Hyeokki
    • Corrosion Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.317-323
    • /
    • 2018
  • Assumptions have always been that wall thinning on the secondary side piping in nuclear power plants is mostly caused by Flow-Accelerated Corrosion (FAC). Recent studies have showed that wall thinning on the secondary side piping is caused by Liquid Droplet Impingement Erosion (LDIE), Solid Particle Erosion (SPE), cavitation, and flashing. To manage those aging mechanisms, several software such as CHECWORKS, COMSY, and BRT-CICERO have been used in nuclear power plants. Korean nuclear power plants have been using the CHECWORKS program since 1996 to date. However, many site engineers have experienced a lot of inconveniences and problems in using the CHECWORKS program. In order to work through the inconveniences and to remedy problems, KEPCO-E&C has developed a "3D-based pipe wall thinning management program (ToSPACE)" based on the experience of over 30 years in relation to the pipe wall thinning management. This study compares the results of FAC and LDIE analysis using both the CHECWORKS and ToSPACE programs with respect to validation of the wall thinning analysis results.

Effects of Aluminum Oxide Particles on the Erosion of Nozzle Liner for Solid Rocket Motors (고체 추진기관에서 산화알루미늄 입자가 노즐 내열재의 삭마에 미치는 영향)

  • 황기영;임유진;함희철
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.8
    • /
    • pp.95-103
    • /
    • 2006
  • The compositions, the gas properties in motor chamber and the aluminum oxide (Al2O3) particle size for two kinds of solid propellants with approximately 20% aluminum powder have been investigated. The SEM photographs of $Al_2O_3$ taken from nozzle entrance liner show that the aluminized PCP propellant with 47% volumetric fraction AP/HNIW and bimodal oxidizer 200-5 ${\mu}m$ can offer greater possibility for increasing aluminum agglomeration than the aluminized HTPB propellant with 64% volumetric fraction AP and trimodal oxidizer 400-200-6 ${\mu}m$. The nozzle entrance liner of solid rocket motor with the PCP propellant shows greater erosion at 4 circumferential sections in line with grain slots due to the impingement of large particles, but that with the HTPB propellant shows uniform erosion with circumferential angle.

Comparison Between FAC Analysis Result Using ToSPACE Program and Experimental Result (ToSPACE 프로그램을 이용한 FAC 해석결과와 실험결과 비교)

  • Hwang, Kyeongmo;Yun, Hun;Seo, Hyukki;Jung, Euije;Kim, Kyungmo;Kim, Dongjin
    • Corrosion Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.131-137
    • /
    • 2020
  • A number of piping components in the secondary system of nuclear power plants (NPPs) are exposed to aging mechanisms, such as flow-accelerated corrosion (FAC), cavitation, flashing, solid particle erosion, and liquid droplet impingement erosion. Those mechanisms may lead to thinning, leaking, or rupture of the components. Due to the pipe ruptures caused by wall thinning in Surry unit 2 in the USA in 1986 and Mihama unit 3 in Japan in 1994, pipe wall thinning management has emerged as one of the most important issues in the nuclear industry. To manage pipe wall thinning, a foreign program has been utilized for NPPs in Korea since 1996. As our experience and knowledge of pipe wall thinning management have accumulated, our program needs to reflect our experience, requests from users, and the result of recent experiments using Flow Accelerated Corrosion Testing System (FACTS). FACTS is the empirical experimental facility developed by Korea Atomic Energy Research Institute (KAERI) for tests. Accordingly, KEPCO-E&C developed a 3D-based pipe wall thinning management program called ToSPACE in 2016. This paper describes a comparison between the FAC analysis results using ToSPACE and the experimental results using FACTS to verify their applicability to pipe wall thinning management in NPPs.