Browse > Article
http://dx.doi.org/10.14773/cst.2012.11.3.089

Development of Inspection Methodology for a Nuclear Piping Wall Thinning Caused by Erosion Using Ultrasonic B-Scan Measurement Device  

Lee, Dae Young (KEPCO E&C)
Suh, Heok Ki (KEPCO E&C)
Hwang, Kyeong Mo (KEPCO E&C)
Publication Information
Corrosion Science and Technology / v.11, no.3, 2012 , pp. 89-95 More about this Journal
Abstract
U.S. Electric Power Research Institute (EPRI) has developed CHECWORKS program and applied it to power plant piping lines since some lines were ruptured by flow-accelerated corrosion (FAC) in 1978. Nowadays the CHECWORKS program has been used to manage pipe wall thinning phenomena caused by FAC. However, various erosion mechanisms can occur in carbon-steel piping. Most common forms of erosion are cavitation, flashing, liquid droplet impingement erosion (LDIE), and Solid Particle Erosion (SPE). Those erosion mechanisms cause pipe wall thinning, leaking, rupturing, and even result in unplanned shutdowns of utilities. Especially, in two phase condition, LDIE damages a wide scope of plant pipelines. Furthermore, LDIE is the major culprit to cause such as power runback by pipe leaking. This paper describes the methodologies that manage wall thinning and also predict LDIE wall thinning area. For this study, current properties of two-phase condition are investigated and LDIE areas are selected. The areas are checked by B-Scan method to detect the effect of wall thinning phenomena.
Keywords
liquid droplet impingement erosion; ultrasonic thickness measurement; B-Scan; A-Scan; wall thinning;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Jeffrey Horowitz, 2004, Recommendations for Controlling Cavitation, Flashing, Flquid Droplet Impingement, and Solid Particl Erosion in Nuclear Power Piping Systems, EPRI, 1011231, p. 3-2 (2004).
2 G. W. Vickers, W. Johnson, Int. J. Mech. Sci., 14, 765 (1972).   DOI   ScienceOn
3 Olympus, EPOCH XT User's Manual, 910-260-EN, Rev. G, p.185 (2011).
4 Jeffrey Horowitz, Recommendations for an Effective Flow-Accelerated Corrosion Program (NSAC-202L-R3), EPRI, p. 4 (2006).