Abstract

A number of piping components in the secondary system of nuclear power plants (NPPs) are exposed to aging mechanisms, such as flow-accelerated corrosion (FAC), cavitation, flashing, solid particle erosion, and liquid droplet impingement erosion. Those mechanisms may lead to thinning, leaking, or rupture of the components. Due to the pipe ruptures caused by wall thinning in Surry unit 2 in the USA in 1986 and Mihama unit 3 in Japan in 1994, pipe wall thinning management has emerged as one of the most important issues in the nuclear industry. To manage pipe wall thinning, a foreign program has been utilized for NPPs in Korea since 1996. As our experience and knowledge of pipe wall thinning management have accumulated, our program needs to reflect our experience, requests from users, and the result of recent experiments using Flow Accelerated Corrosion Testing System (FACTS). FACTS is the empirical experimental facility developed by Korea Atomic Energy Research Institute (KAERI) for tests. Accordingly, KEPCO-E&C developed a 3D-based pipe wall thinning management program called ToSPACE in 2016. This paper describes a comparison between the FAC analysis results using ToSPACE and the experimental results using FACTS to verify their applicability to pipe wall thinning management in NPPs.

Keywords

References

  1. EPRI, TR-1011231J, J. Horowitz, Recommendations for controlling cavitation, flashing, liquid droplet impingement erosion, and solid particle erosion in nuclear power plant piping systems, Final Report (2004).
  2. NRC Bulletin 87-01, Thinning of pipe walls in nuclear power plants (1987).
  3. Maeda and Amano, Automatic Shutdown of Unit 3 - 4th Report, NISA/METI Press Release (2004).
  4. K. M. Hwang, H. Yun, H. K. Seo, G. Y, Lee, and K. W. Kim, World J. Nucl. Sci. Technol., 9, 1 (2019). https://doi.org/10.4236/wjnst.2019.91001
  5. KAERI, KAERI/TR-7513/2018, Pipeline FAC evaluation technology using asymmetric flow analysis, Technical Report (2018).
  6. K. M. Hwang, H. Yun, and H. K. Seo, Corros. Sci. Tech., 17, 317 (2018). https://doi.org/10.14773/cst.2018.17.6.317