• 제목/요약/키워드: Particle Counter

검색결과 211건 처리시간 0.028초

Dynamics of charged particles around a compact star with strong radiation

  • 오재석;김홍수;이형목
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.54.2-54.2
    • /
    • 2011
  • It is the conventional wisdom that the Poynting-Robertson effect is essentially the outcome of the interplay between absorption and reemission processes. For a better understanding of the motion of charged particles around a compact star with strong radiation, we reached an alternative interpretation for the Poynting-Robertson effect based on the covariant formalism and found that it is attributed to the combination of the aberration and the Lorentz transformation of the radiation stress-energy tensor. As a general relativistic application of the Poynting-Robertson effect, we studied the dynamics of test particles around the spinning relativistic star with strong radiation. We discovered that the combination of the angular momentum and the finite size of the star generates "radiation counter drag" which exerts on the test particle to enhance its specific angular momentum, contrary to the radiation drag. The balance of the radiation drag and the radiation counter drag renders the particle to hover around the spinning luminous star at the "suspension orbit". The radial position and the angular velocity of the particle on the "suspension orbit" are determined by the angular momentum, the luminosity, and the size of the central star only, and they are independent of the initial position and velocity of the particle.

  • PDF

부산 도심지에서 측정된 에어로졸 농도의 물리적 특성 (Physical Characteristics of Aerosol Concentrations Observed in an Urban Area, Busan)

  • 김연종;김철희
    • 한국환경과학회지
    • /
    • 제19권3호
    • /
    • pp.331-342
    • /
    • 2010
  • Aerosol physical properties have been measured at Pusan National University by using the 16-channel LPC(Laser Particle Counter), and particle characteristics have been examined for the period from Aug. 4 2007 to Dec. 30, 2008. Annual total average, seasonal average, and other averages of the meteorologically classified four categories such as Asian dust, precipitation, foggy, and clear days are respectively described here. Both annually and seasonally averaged number concentration show three peaks at the particle diameter of 0.3, 1.3, and $4{\mu}m$, respectively. However, the first peak for summer season tends to be shifted toward smaller size than other seasons, implying the strong fine particle generation. Meteorological condition shows strong contrast in aerosol concentrations. In Asian dust case, relatively lower number concentrations of fine particles (i.e., smaller than $0.5{\mu}m$) were predominant, while higher concentrations of coarse particles were found particularly for the size bigger than $0.5{\mu}m$. In precipitation day, number concentrations were decreased by approximately 30% due to the removal process of precipitation. Foggy day shows significantly higher concentrations for fine particles, implying the importance of the aerosol condensation process of micro-fine-particle growing to fine-particle. Finally the regressed particle size distribution function was fitted optimally with two log-normal distribution, and discussed the similarities and differences among four categorized cases of the Asian dust, precipitation, foggy, and clear days.

A study on analysis of particle size distribution

  • Min, Shin-Hong
    • Archives of Pharmacal Research
    • /
    • 제3권2호
    • /
    • pp.65-74
    • /
    • 1980
  • Analysis of particle size distribution of a sample of fine aluminum hydroxide powder was carried out by four different methods, i. e., conductivity, air permeability, gas-adsorption and sedimentation. Each method was reproducible. The results obtained by Coulter counter and sedimentation balance were similar, and the data obtained by Lea and Nurse permeameter and Stroehlein areameter were also similar. But the results differ considerabley between the former and the latter. The advantages and disavantages of each method were discussed briefly and a means of comparing the results with those obtianed by surface area measurements was shown.

  • PDF

입자의 형상에 따른 열영동 영향에 대한 실험적 연구 (Experimental Study on Thermophoretic Particle Deposition for an Agglomerated and Non-Agglomerated Particles)

  • 최광열;윤진욱;안강호
    • 대한기계학회논문집B
    • /
    • 제28권7호
    • /
    • pp.741-746
    • /
    • 2004
  • Agglomerated and non-agglomerated SiO$_2$ particles are synthesized in a furnace by oxidation of TEOS vapor. These polydispersed particles are classified with DMA to extract particles. Then these particles are introduced into a thermal precipitator through the ESP(Electrostatic Precipitator) to investigate the themophoretic particle deposition using CNCs(Condensation Nuclei Counter). The efficiency of themophoretic particle deposition according to agglomerated and non-agglomerated particles in the thermal precipitator has been studied as a function of particle size and TEOS mole concentration using monodisperse particles classified by DMA. The results show that the particle deposition efficiency decreases as TEOS mole concentration increases and particle size increases. Thereffre, it is concluded that the thermophoretic deposition efficiency is dependent of the particle morphology.

응집입자와 비응집 입자의 CNC 내에서 응축성장에 관한 실험적 연구 (The growth effect of agglomerated and nonagglomerated particles in Condensation Nuclei Counter (CNC))

  • 김영원;문형우;윤진욱;안강호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.579-584
    • /
    • 2001
  • Agglomerated and nonagglomerated SiO2 particles are synthesized in furnace by the electrohydrodynamic spraying method and the vapor feeding method for the test particle generator this study. These polydispersed particles are classified with DMA to extract equal mobility particles. Then these particles are introduced into CNC (Condensation Nuclei Counter) to see the pulse height using Multi-channel Analyzer. The response characteristics of these two kinds of particles in CNCs (TSI CNC 3022 and 3025A) have been studied as a function of particle size using mono disperse particles classified by DMA. The results show that the higher drag resistance particles, so called agglomerated particles have generated a lower CNC pulse height than the spherical particles for these two different CNCs, which means the nonagglomerated particles may start to grow larger than the agglomerated particles.

  • PDF

Precise Measurement of Beam Energy and Range with TOF and Counter Telescope System

  • Nanbu, Shuya;Kanai, Tatsuaki;Kohno, Toshiyuki;Ohno, Yumiko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.225-227
    • /
    • 2002
  • In order to improve the accuracy of charged-particle radiation therapy, the beam energy was measured precisely using a TOF-system, and the range using a counter telescope system. A Si detector and a Ge detector were used to estimate the range straggling as a $\Delta$E and an E detector, respectively, because they have good energy resolution and the output pulse heights don't depend on the atomic number of detected particles. The results were compared with the theoretical values by a calculation code.

  • PDF

Construction of a Dynamic Laser Light Scattering System Using a Personal Computer$^\dag$

  • Kim, Myung-Joong;Lee, Sang-Yong;Chung, Koo-Soon;Lee, Hoo-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • 제8권5호
    • /
    • pp.403-405
    • /
    • 1987
  • A dynamic laser light scattering system has been constructed using a personal computer. The intensity of the scattered light was detected with a photomultiplier tube and a photon counter. The BCD output of the photon counter which is proportional to the intensity of scattered light is fed into a personal computer via an interface card. The personal computer was programmed as an autocorrelator in machine language. The data acquisition rate of the system was about 600 samples/s which is adequate for studies on the molecular dynamics of concentrated polymer solutions, polymer latices with large particle size, and polymer glass systems. The constructed system was tested with polystyrene latex and the measured diameter of the latex particle agrees well with the supplier's value.

자동차 주행풍과 브레이크 캘리퍼 위치에 따른 비산먼지 포집기의 특성연구 (A Study on the Evaluation of a Scattering Dust Collector in Vehicle-Induced Wind and Brake Caliper Locations)

  • 손병래;안준형;이영환;황영국
    • 한국기계가공학회지
    • /
    • 제21권3호
    • /
    • pp.43-48
    • /
    • 2022
  • A scattering dust collector in automobile brake pads was investigated in this study. The dust scattering was measured by mounting a booth with a particle counter for both the vehicle-induced wind and brake caliper locations. In addition, the collection effect of the dust scattering was analyzed using the designed dust collector. The results of this study can be used to develop an advanced dust collector and the field test modes for dust scattering in an automotive brake system.

SMPS(Scanning Mobility Particle Sizer)를 이용한 안산지역 대기중 초미세입자(30\~500nm) 분포연구 (Monitoring of Airborne Fine Particle using SMPS in Ansan Area)

  • 김용민;안강호
    • 한국대기환경학회지
    • /
    • 제21권3호
    • /
    • pp.295-301
    • /
    • 2005
  • The fine particles in the range of $30\~500nm$ are monitored at Hanyang University campus in Ansan using house made DMA (differential mobility analyzer) and commercial CPC (condensation particle counter, TSI inc.) in SMPS mode. The monitoring period is March 16th 2004 through May 7th, 2004. During the monitoring period, Aitken nuclei mode $(30\~100nm)$ particle concentration has a tendency of increase in the morning and evening hours. However, the accumulation mode $(100\~500nm)$ particle concentration stays rather stable than that of Aitken mode.

조리과정에서 생성된 미세먼지의 크기분포 특성 (Size Distribution Characteristics of Particulate Matter Emitted from Cooking)

  • 주상우;지준호
    • 한국입자에어로졸학회지
    • /
    • 제16권1호
    • /
    • pp.9-17
    • /
    • 2020
  • The characteristics of particulate matter made from daily cooking at a Korean residential apartment house with three dwellers had been investigated for about 3 months. All data were recorded by an optical particle counter every minute at the kitchen. Types of cooking such as boiling, frying, and grilling that performed in the house were listed. Boiling only was used in 32% cases among total 234 meals. Frying and grilling were 14% and 11%, respectively. From an initial indoor particulate matter smaller than 10 ㎛ in diameter, the increases due to cooking are reported by size. In case of boiling, PM at 1-10 ㎛ size and under 1 ㎛ size little increased. Normally, particles from oil or combustion in a process of frying or grilling increased indoor PM. In a case of grilling, particle mass concentration in a region of 1-10 ㎛ in diameter increased as much as 295 ㎍/㎥. Mass concentration of particles smaller than 1 ㎛ increased as much as 33 ㎍/㎥.