• Title/Summary/Keyword: Partial flow rate

Search Result 230, Processing Time 0.025 seconds

The Base Sequence of ITS and Genetic Variation in Sarcodon Aspratus (능이버섯의 ITS염기서열과 유전적 변이)

  • Kim Jong Bong
    • Journal of Life Science
    • /
    • v.14 no.6 s.67
    • /
    • pp.963-966
    • /
    • 2004
  • The sequence of ITS (partial 16S ribosomal DNA, complete ITS1, 5.8S ribosomal DNA and ITS2, and partial 28S ribosomal DNA) was analysed by PCR and autosequencing in Sarcodon aspratus. The ITS lenght of S. aspratus was 716 base pair. As this sequence compared with other reports on S. aspratus (ace No AF335110), the sequence variation based on nucleotide deletion and substitution was $1.8\%$. This nucleotide variation rate in same species was very higher than in other species. Also, the sequence varitation rates between this S. aspratus and S. imbricatus, and S. squamus were $8\%\;and\;10\%$, respectively. This results suggested that the high sequence variation of S. aspratus might be caused specific host and inhabitat environment which limited gene flow.

A Study on the Optimum Design for LTCC Micro-Reformer: Design and performance evalution of monolith fuel reformer/PROX (LTCC를 소재로 하는 마이크로 리포머의 최적 설계에 관한 연구 ; 일체형 Reformer/PROX 반응기의 설계 및 성능평가)

  • Chung, C.H.;Oh, J.H.;Jang, J.H.;Jeong, M.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.10a
    • /
    • pp.615-616
    • /
    • 2006
  • A micro-fuel processor system integrating steam reformer and partial oxidation reactor was manufactured using low temperature cofired ceramic (LTCC). A CuO/ZnO/$Al_2O_3$ catalyst and Pt-based catalyst prepared by wet impregnation were used for steam reforming and partial oxidation, respectively. The performance of the LTCC micro-fuel processor was measured at various operating conditions such as the effect of the feed flow rate, the ratio of $H_2O/CH_3OH$, and the operating temperature on the LTCC reformer and CO clean-up system. The catalyst layer was loaded with "Fill and Dry" coating for small volume. The product gas was composed of $70\sim75%$ hydrogen, $20\sim25%$ carbon dioxide, and $1\sim2%$ carbon monoxide at $250\sim300^{\circ}C$, respectively.

  • PDF

Investigation on the Effective Calibration of Annubar (다점식 피토관의 효율적인 교정에 대한 연구)

  • Choi Yong-Moon;Choi Hae-Man;Choi Ji-Chul;Hong Kyung-Ki;Han Sang-Woo;Kim Woong-Sun;Chun Se-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.4 s.247
    • /
    • pp.373-380
    • /
    • 2006
  • Annubar is one of popular tools to measure the exhausted gas flow rate from the stacks. For the accurate monitoring of the amount of discharged pollutants, calibration of annubar is very important. Calibration of annubar has been carried out in a wind tunnel. When the length of annubar is longer than the test section size of wind tunnel, it is very difficult to find out typical value of annubar coefficients. So, a measurement technique to calibrate annubar longer than the size of the test section of wind tunnel must be developed. In the present study, an experiment is performed to measure the annubar coefficients in such a limited size of the wind tunnel. The experimental annubar coefficient by using a partial blocking technique is very close to the annubar coefficient of normal condition.

Experimental Investigation on premixed combustion Characteristics with suction & blow fans (송풍기와 폐풍기를 이용한 연소기내의 부분 예혼합화염 연소 특성에 관한 실험적 연구)

  • Kang, B.K.;Oh, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.143-148
    • /
    • 2001
  • We measured emission indices for $NO_x$, CO, temperature and radical characteristics for partially premixied flames formed by suction & blow fans air condition. At sufficiently high levels of partial premixing a double flame structure consisting of a rich premixed inner flame and outer diffusion flame was established similar to that previously observed in premixed flames. $NO_x$, Temperature, CO values were experimented with approximately constant air flow rate and decreasing equivalence ratios. The reduction in $NO_x$ and temperature at suction condition as compared with that for blow condition was approximately 20%, but on the contrary, CO emission was increased. In addition, We measured temperature distributions and found that temperature increased continuously with increasing partial premixing. We also estimated CH, $C_2$ radical intensity. CH and $C_2$ radicals provide evidence that, for the present measurement, CH and $C_2$ radicals intensity was associsated with their premixed component. And we observed stronger $C_2$, CH radicals intensity at suction conditions than blow conditions.

  • PDF

Study on the characteristics of the plasma induced by lap-joint $CO_2$ laser welding of automotive steel sheets (자동차용 강판의 겹치기 $CO_2$ 레이저 용접에서 발생되는 플라즈마 특성에 관한 연구)

  • 남기중;박기영;이경돈
    • Laser Solutions
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 2002
  • In order to investigate the characteristics of the plasma induced by lap-joint CO$_2$ laser welding of automotive steel sheets, the effects of welding speed, shield gas flow rate, gap size, and laser beam defocus to plasma intensity emitted from keyhole have been investigated. The plasma light is measured by fiber and photodiode. Also, the plasma images were captured by the high speed digital camera in 1000frames/sec in order to correlate the plasma light signal with plasma pattern. From the results, it is observed that the difference of the plasma intensity for between the deep penetration and partial penetration exists from 1.2 to 2 times. The plasma light intensity decreased in case of the deep penetration Is observed due to the exhausting of the plasma gas under the sheet. On the other hand, under the conditions of the deep penetration, the plasma intensity is significantly increased by controling the conditions decreasing the penetration depth. It was specially founded that the effect of 0.3mm gap size at partial penetration condition is approximately similar to deep penetration in 0mm gap. It is concluded that the plasma intensity is able to evaluate the penetration depth in lap-joint welding and appears to offer the most straightforward correlation to the welding process.

  • PDF

Experimental Investigation on Premixed Combustion Characteristics with Suction & Blow Fans (Suction과 blow fan을 이용한 연소기내의 부분 예혼합화염 연소 특성에 관한 실험적 연구)

  • Kang, Ki-Bal;Kim, Dong-Il;Oh, Sang-Heun
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.2
    • /
    • pp.15-23
    • /
    • 2002
  • We measured emission indices for $NO_x$, CO, temperature and radical characteristics for partially premixied flames formed by suction & blow fans air condition. At sufficiently high levels of partial premixing a double flame structure consisting of a rich premixed inner flame and outer diffusion flame was established similar to that previously observed in premixed flames. $NO_x$, Temperature. CO concentration were experimented with approximately constant air flow rate and decreasing equivalence ratios. The reduction in $NO_x$, and temperature at suction condition as compared with that for blow condition was approximately 20%, but on the contrary, CO emission was increased. In addition, We measured temperature distributions and found that temperature increased continuously with increasing partial premixing. We also estimated CH, $C_2$ radical intensity. CH and $C_2$ radicals provide evidence that, for the present measurement, CH and $C_2$ radicals intensity was associsated with their premixed component. And we observed stronger $C_2$, CH radicals intensity at suction conditions than blow conditions.

  • PDF

Process Diagnosis of Reactive Deposition of MgO by ICP Sputtering System (유도결합 플라즈마 스퍼터링 장치에서 MgO의 반응성 증착 시 공정 진단)

  • Joo, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.5
    • /
    • pp.206-211
    • /
    • 2012
  • Process analysis was carried out during deposition of MgO by inductively coupled plasma assisted reactive magnetron sputtering in Ar and $O_2$ ambient. At the initiation of Mg sputtering with bipolar pulsed dc power in Ar ambient, total pressure showed sharp increase and then slow fall. To analyse partial pressure change, QMS was used in downstream region, where the total pressure was maintained as low as $10^{-5}$ Torr during plasma processing, good for ion source and quadrupole operation. At base pressure, the major impurity was $H_2O$ and the second major impurity was $CO/N_2$ about 10%. During sputtering of Mg in Ar, $H_2$ soared up to 10.7% of Ar and remained as the major impurity during all the later process time. When $O_2$ was mixed with Ar, the partial pressure of Ar decreased in proportion to $O_2$ flow rate and that of $H_2$ dropped down to 2%. It was understood as Mg target surface was oxidized to stop $H_2$ emission by Ar ion sputtering. With ICP turned on, the major impurity $H_2$ was converted into $H_2O$ consuming $O_2$ and C was also oxidized to evolve CO and $CO_2$.

Long Length YBCO Coated Conductors Prepared by an MOD Process on Buffered Metallic Tapes

  • Chung, Kook-Chae;Yoo, Jai-Moo;Ko, Jae-Woong;Kim, Young-Kuk;Kim, Tae-Hyung;Ko, Rock-Kil
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.4
    • /
    • pp.12-14
    • /
    • 2006
  • YBCO coated conductors have been fabricated by the reel-to-reel processing using TFA-MOD method. In this work, the fluorine-free Y & Cu precursor solution was synthesized to shorten the calcining time by reducing the evolution of HF gas, thus the meter-long YBCO precursor films can be made within few hours by the continuous slot-die coating & calcination step using the F-free Y & Cu precursor solution. The annealing step was followed to make the YBCO films by the reel-to-reel method with the vertical gas flow system onto the moving tape. To increase the growth rate of the YBCO films by enhancing the removal of HF gas, the low total pressure was adopted in the annealing processing. And the water partial pressure and the oxygen partial pressure were varied to optimize the growth conditions of the MOD-YBCO films on the buffered metal tape. FE-SEM and XRD were used to investigate the surface morphologies and the texture of the meter-long YBCO films. The end-to-end critical current $(I_c)$ of 63A/cm-width and the critical current density $(J_c)$of $0.9MA/cm^2$ with the thickness of $0.7{\mu}m$ were obtained in the 0.42m long coated conductor.

Experimental Study on the Effective Use of Thermally Stratified Hot Water Storage System (열성층 온수저장시스템의 효율적 이용에 관한 실험적 연구)

  • Pak, Ee-Tong
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.45-52
    • /
    • 1993
  • The benefits of thermal stratification in sensible heat storage were investigated for residential solar applications. The effect of increased thermal useful efficiency of hot water stored in an actual storage tank due to stratification has been discussed and illustrated through experimental data and computer simulation, which were taken by changing dynamic and geometric parameters. When the flow rate was 8 liter/min and ${\Delta}T=40^{\circ}C$ was $40^{\circ}C$, the useful efficiency(${\eta}_u$) was about 90% in case of using a distributor, but not using a distributor the useful efficiency(${\eta}_u$) was about 82%. So these kinds of distributor would be recommendable for a hot water storage system and residential solar energy application to increase useful efficiency(${\eta}_u$). In the case of the uniform circular distributor, when the flow rate was 8 liter/min partial mixing was decreased and a stable stratification was obtained. Furthermore, if the distrbutor was manufactured so that the flow is to be the same from all perforations in order to enhance stratification, it might be predicted that further stable stratification and higher useful efficiency(${\eta}_u$) are obtainable.

  • PDF

A Study on Measuring Method of Wind Resources for Wind Farm Design (풍력단지 설계를 위한 풍황자원의 측정방법 연구)

  • Sung-Min Han;Geon-Ung Gim;Sang-Man Kim;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.3
    • /
    • pp.387-396
    • /
    • 2023
  • The representative equipments currently used for weather observations are meteorological masters and wind lidars. According to international regulations, meteorological masters can be used for standalone measurements, but in case of wind lidars, it is mandatory to install a meteorological master that matches the height of the bottom of the wind turbine blade or a 40m meteorological masters and correct the measurement data. Turbulence flow occurs frequently at altitudes below 100m due to its nature, and wind lidars are more susceptible to the effects of turbulence than meteorological masters. However, while the turbulence intensity for meteorological masters is specified by international regulations, there is no separated specification for wind lidars. This study collected data measured under the same conditions using both meteorological masters and wind LiDARs, analyzed the uncertainties and turbulence intensity ratio. The analysis of the data showed that there were partial sections where the proportion of turbulent flow intensity exceeded 3%. Therefore, it is suggested to include a specification for the turbulence intensity error rate for wind LiDARs in the international regulations.