Investigation on the Effective Calibration of Annubar |
Choi Yong-Moon
(한국표준과학연구원 기반표준부 역학그룹)
Choi Hae-Man (한국표준과학연구원 기반표준부 역학그룹) Choi Ji-Chul (환경관리공단 측정관리처 측정기검사팀) Hong Kyung-Ki (환경관리공단 측정관리처 측정기검사팀) Han Sang-Woo (환경관리공단 측정관리처 측정기검사팀) Kim Woong-Sun (환경관리공단 측정관리처 측정기검사팀) Chun Se-Jong (한국표준과학연구원 기반표준부 역학그룹) |
1 | Seshadri, V., Gandhi, B. K., Singh, S. N. and Pandey, R. K., 2004, 'Analysis of the Effect of Body Shape on Annubar Factor Using CFD Measurement, Vol. 35, pp. 25-32 DOI ScienceOn |
2 | Dieterich Standard, 1998, 'Anubar: Averaging Pitot Tube Installation and Operation Manual,' 00809-0100-4760, Rosemount Inc |
3 | International Standard Organization, 1977, 'Measurement of Fluid Flow in Closed Conduits Velocity Area Method Using Pitot Static Tubes,' ISO 3966, Geneva, Swiss |
4 | Chung, M. S. (Ed.), 1998, 'KRISS Guide to the Expression of Uncertainty in Measurement,' KRISS-98-096-SP |
5 | Hong, K. K., Choi, Y. M., Lee, S. H., Choi, J. C., Kim, W. S. and Ko, J. Y., 2005, 'Performance Test of a Calibration Wind Tunnel as a Means to Authenticate Anemometers for the Stacks,' Wind Tunnel Workshop, May 4, KARI, Daejeon, Korea |
6 | Jones, F. E. and Schoonover, R M., 2002, 'Handbook of Mass Measurement,' pp. 120-131, CRC Press |
7 | Kline, S. J. and McClintock, F. A., 1953, 'Describing Uncertainty in Single-Sample Experiments,' Mechanical Engineering, Vol. 75, pp. 3-8 |