• Title/Summary/Keyword: Partial discharge type electrode

Search Result 24, Processing Time 0.029 seconds

A Study on Signal Feature Extraction of Partial Discharge Types Using Discrete Wavelet Transform Technique (이산웨이블렛 변환기법을 이용한 부분방전종류의 신호특징추출에 관한연구)

  • Park, Jae-Jun;Jeon, Byung-Hoon;Kim, Jin-Seong;Jeon, Hyun-Gu;Baek, Kwan-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.170-176
    • /
    • 2002
  • In this papers, we proposed the feature extraction method due to partial discharge type of transformers. For wavelet transform, Daubechie's filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about acoustic emission signal generated from each partial discharge type. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC electrode and Void electrode. Also, these coefficients are used to identify signal of partial discharge type electrode fault in transformer. As a result, from compare of acoustic emission amplitude and acoustic average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise, In case of skewness and kurtosis, we are obtained results of Needle-Plane electrode electrode> Void electrode> IEC electrode.

  • PDF

A Study on Feature Extraction of Partial Discharge Type Using Wavelet Transform (웨이블렛변환을 이용한 부분방전 종류의 특징추출에 관한 연구)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.6 no.1
    • /
    • pp.65-70
    • /
    • 2003
  • In this papers, we proposed the new method in order to diagnosis partial discharge type of transformers. For wavelet transform, Daubechie's filter is used,, we can obtain wavelet coefficients which is used to extract featrue of statistical parameters(maximum value, average value, dispersion, skewness, kurtosis) about high frequency current signal per 3-electrode type(needle-plane electrode, IEC electrode and Void electrode). Also, these coefficients are used to identify signal of internal partial discharge in transformer. As a result, from compare of high frequency current signal amplitude and average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. Otherwise, in case of skewness and kurtosis, we are obtained results of Void electrode> IEC electrode> Needle-Plane electrode. As improved method in order to diagnosis partial discharge type of transformers, we use neural network.

  • PDF

A Study on Diagnosis of Partial Discharge Type Using Wavelet Transform-Neural Network (웨이블렛-신경망을 이용한 부분방전 종류와 진단에 관한연구)

  • Park, Jae-Jun;Jeon, Hyun-Gu;Jeon, Byung-Hoon;Kim, Sung-Hong;Kwon, Dong-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.894-899
    • /
    • 2002
  • In this papers, we proposed the new method in order to diagnosis partial discharge type of transformers. For wavelet transform, Daubechies filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about high frequency current signal per 3-electrode type (needle-plane electrode, IEC electrode and Void electrode.). Also. these coefficients are used to identify Signal of internal partial discharge in transformer. As a result. from compare of high frequency current signal amplitude and average value. we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise. In case of skewness and kurtosis, we are obtained results of Void electrode> IEC electrode > Needle-Plane electrode. As Improved method in order to diagnosis partial discharge type of transformers, we use neural network.

  • PDF

Effect of Electric Frequency on the Partial Discharge Resistance of Epoxy Systems with Two Diluents

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.6
    • /
    • pp.317-320
    • /
    • 2013
  • Partial discharge resistance for the epoxy systems with two diluents was investigated in the rod-plane electrodes arrangement, and the effect of electric frequency on the partial discharge resistance was also studied. Diglycidyl ether of bisphenol A (DGEBA) type epoxy was used as a base resin, and 1,4-butanediol diglycidyl ether (BDGE) or polyglycol (PG) as a reactive diluent was introduced to the DGEBA system, in order to decrease the viscosity of the DGEBA epoxy system. BDGE was acted as a chain extender, and PG acted as a flexibilizer, after the curing reaction. To measure the partial discharge resistance, 5 kV alternating current (ac) with three different frequencies (60, 500 and 1,000 Hz) was applied to the specimen in a rod-plane electrode arrangement, at $30^{\circ}C$. PG had a good effect, while BDGE had a bad effect on the partial discharge resistance of the DGEBA system, regardless of the electric frequency.

A New Type of Nonthermal Plasma Reactor

  • Geum, Sang-Taek;Moon, Jae-Duk;Jun, Sun-Gon
    • The Korean Journal of Ceramics
    • /
    • v.5 no.3
    • /
    • pp.245-249
    • /
    • 1999
  • A new type of nonthermal plasma reactor utilizing ferroelectric pellets is proposed to generate nonthermal plasma efficiently, which is used for simultaneous control of various pollutant gases. Electric charges stored on ferroelctric pellets by corona discharge between a corona tip and a mesh electrode provide partial electrical discharges among ferroelectric pellets. These partial electrical discharges can enhance partial discharges around the surface of ferroelectric pellets. This method utilizes wide reacting area of ferroelectric pellets and partial discharge. Positive and negative dc voltage are applied to the corona tip to generate partial discharges, and corona currents are estimated to investigate charge storage on ferroelectric pellets as function of time and charge relaxation time constants of ferroelectric pellects. As a result, charge relaxationtime, dielectric constants of ferroelectric pellets, polarity of applied voltage and applied time influence partial discharges among ferroelectric pellect.

  • PDF

Internal PD Pulses Analysis Accompanying with Bush-type Tree in Solid Dielectrics (고체유전체에서 발생한 부시형 전기트리에 수반된 내부 부분방전 펄스 해석)

  • 강성화;홍현문;류부형
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.100-105
    • /
    • 2000
  • Correlation between propagation of bush-type electrical tree and internal partial discharges(PD) was discussed. We used specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope interfaced with computer and investigated characteristics of phase resolved PD pulses accompanying with propagation of electrical tree. Electrical tree generally growed bush-type tree. PD data detected and analyzed were average discharge current and statistical operator of q-n, $\psi$- $q_{avg}$, $\psi$-n, ${\psi}-q_{max}$ distribution. Parameters used were skewness, kurtosis, average discharge phase, cross-correlation factor, asymmetry and etc. In generally, average discharge current had good linear relationship with propagation of bush type electrical tree on this experiment. Peak discharge magnitude and repetition rate were increased, but they had not good linear relationship.p.

  • PDF

Development of the CuN/Cu/CuN type Electrode Material for the PDP (PDP용 CuN/Cu/CuN 전극재료의 개발에 관한 연구)

  • 성열문;정신수;류재하;김재성;조정수;박정후
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.55-58
    • /
    • 1996
  • A new type CuN/Cu/CuN thin film electrode material with high adhesion to glass was developed by the dc reactive planar magnetron sputtering system for the PDP(Plasma Display Panel). The adhesive force of the CuxN thin film was in the range of 20∼40(N) under the conditions of the N$_2$ partial pressure of 15%, discharge current of 70mA, discharge voltage of 450v and substrate bias voltage of -100V. The adhesive force was depended on the N$_2$ partial Pressure, discharge current and substrate bias voltage.

  • PDF

A Study on Developement of CuN/Cu/CuN Electrode Material for PDP (PDP용 CuN/Cu/CuN 전극재료의 개발에 관한 연구)

  • Cho, J.S.;Park, C.H.;Sung, Y.M.;Jeong, S.S.;Seok, B.Y.;Ryu, J.Y.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1572-1575
    • /
    • 1996
  • A new type $Cu_{x}N/Cu/Cu_{x}N$ thin film electrode material with high adhesion to glass was developed by the dc reactive planar magnetron sputtering system for the PDP(Plasma Display Panel). The adhesive force of the $Cu_{x}N$ thin film was in the range of $20{\sim}40(N)$ under the conditions of the $N_2$ partial pressure of 15%, discharge current of 70mA, discharge voltage of 450V and substrate bias voltage of -100V. The adhesive force was depended on the $N_2$ partial pressure, discharge current and substrate bias voltage.

  • PDF

Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers (몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작)

  • Lee, Gyeong-Yeol;Kim, Sung-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.

New Address Electrode Suitable for Fast Addressing with High Xe ac-PDP

  • Lee, Don-Kyu;Lee, Ho-Jun;Lee, Hae-June;Kim, Dong-Hyun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.564-567
    • /
    • 2004
  • New address electrode having separated dual electrode is suggested to reduce addressing time in ac PDP. Addressing characteristics of suggested electrode has been investigated in the test panel with high Xe partial pressure. It has been found that both the formative and jitter width of the suggested electrode is improved by 10 -20 % over the wide range of address voltage level compared with the conventional one. The dynamic margin of the panel also greatly improved. The key feature behind this type of structure is that it can extend the controllability of the wall charge distribution during the reset and address discharge without significant increase in capacitive load of address electrode.

  • PDF