New Address Electrode Suitable for Fast Addressing with High Xe ac-PDP
- Lee, Don-Kyu (Department of Electrical Engineering, Pusan National University) ;
- Lee, Ho-Jun (Department of Electrical Engineering, Pusan National University) ;
- Lee, Hae-June (Department of Electrical Engineering, Pusan National University) ;
- Kim, Dong-Hyun (Department of Electrical Engineering, Pusan National University) ;
- Park, Chung-Hoo (Department of Electrical Engineering, Pusan National University)
- Published : 2004.08.23
Abstract
New address electrode having separated dual electrode is suggested to reduce addressing time in ac PDP. Addressing characteristics of suggested electrode has been investigated in the test panel with high Xe partial pressure. It has been found that both the formative and jitter width of the suggested electrode is improved by 10 -20 % over the wide range of address voltage level compared with the conventional one. The dynamic margin of the panel also greatly improved. The key feature behind this type of structure is that it can extend the controllability of the wall charge distribution during the reset and address discharge without significant increase in capacitive load of address electrode.