• 제목/요약/키워드: Partial discharge type electrode

검색결과 24건 처리시간 0.023초

이산웨이블렛 변환기법을 이용한 부분방전종류의 신호특징추출에 관한연구 (A Study on Signal Feature Extraction of Partial Discharge Types Using Discrete Wavelet Transform Technique)

  • 박재준;전병훈;김진승;전현구;백관현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.170-176
    • /
    • 2002
  • In this papers, we proposed the feature extraction method due to partial discharge type of transformers. For wavelet transform, Daubechie's filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about acoustic emission signal generated from each partial discharge type. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC electrode and Void electrode. Also, these coefficients are used to identify signal of partial discharge type electrode fault in transformer. As a result, from compare of acoustic emission amplitude and acoustic average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise, In case of skewness and kurtosis, we are obtained results of Needle-Plane electrode electrode> Void electrode> IEC electrode.

  • PDF

웨이블렛변환을 이용한 부분방전 종류의 특징추출에 관한 연구 (A Study on Feature Extraction of Partial Discharge Type Using Wavelet Transform)

  • 박재준
    • 정보학연구
    • /
    • 제6권1호
    • /
    • pp.65-70
    • /
    • 2003
  • 본 논문에서 우리는 변압기의 부분방전형태를 진단하기위하여 새로운 방법을 제시하였다. 웨이블렛 변화을 위하여, 다우비치 필터가 사용되어졌다. 우리는 3개의 전극 종류(침대평판자극, IEC전극, 보이드 전극)마다 고주파 전류신호에 관한 통계적인 특징 파라메터(최대값, 평균값, 분산, 왜도, 첨쇄도)를 추출하기위하여 사용하였다. 역시 이들 계수들은 변압기내 내부부분방전의 신호의 정체를 알기위하여 사용되어졌다. 그 결과로서 고주파전류신호의 진폭과 평균값의 비교로부터 우리는 IEC electrode> Void electrode> Needle-Plane electrode의 결과를 얻었다. 반면에 왜도와 첨쇄도의 경우, 우리는 Void electrode> IEC electrode> Needle-Plane electrode을 얻었다.

  • PDF

웨이블렛-신경망을 이용한 부분방전 종류와 진단에 관한연구 (A Study on Diagnosis of Partial Discharge Type Using Wavelet Transform-Neural Network)

  • 박재준;전현구;전병훈;김성홍;권동진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.894-899
    • /
    • 2002
  • In this papers, we proposed the new method in order to diagnosis partial discharge type of transformers. For wavelet transform, Daubechies filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about high frequency current signal per 3-electrode type (needle-plane electrode, IEC electrode and Void electrode.). Also. these coefficients are used to identify Signal of internal partial discharge in transformer. As a result. from compare of high frequency current signal amplitude and average value. we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise. In case of skewness and kurtosis, we are obtained results of Void electrode> IEC electrode > Needle-Plane electrode. As Improved method in order to diagnosis partial discharge type of transformers, we use neural network.

  • PDF

Effect of Electric Frequency on the Partial Discharge Resistance of Epoxy Systems with Two Diluents

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권6호
    • /
    • pp.317-320
    • /
    • 2013
  • Partial discharge resistance for the epoxy systems with two diluents was investigated in the rod-plane electrodes arrangement, and the effect of electric frequency on the partial discharge resistance was also studied. Diglycidyl ether of bisphenol A (DGEBA) type epoxy was used as a base resin, and 1,4-butanediol diglycidyl ether (BDGE) or polyglycol (PG) as a reactive diluent was introduced to the DGEBA system, in order to decrease the viscosity of the DGEBA epoxy system. BDGE was acted as a chain extender, and PG acted as a flexibilizer, after the curing reaction. To measure the partial discharge resistance, 5 kV alternating current (ac) with three different frequencies (60, 500 and 1,000 Hz) was applied to the specimen in a rod-plane electrode arrangement, at $30^{\circ}C$. PG had a good effect, while BDGE had a bad effect on the partial discharge resistance of the DGEBA system, regardless of the electric frequency.

A New Type of Nonthermal Plasma Reactor

  • Geum, Sang-Taek;Moon, Jae-Duk;Jun, Sun-Gon
    • The Korean Journal of Ceramics
    • /
    • 제5권3호
    • /
    • pp.245-249
    • /
    • 1999
  • A new type of nonthermal plasma reactor utilizing ferroelectric pellets is proposed to generate nonthermal plasma efficiently, which is used for simultaneous control of various pollutant gases. Electric charges stored on ferroelctric pellets by corona discharge between a corona tip and a mesh electrode provide partial electrical discharges among ferroelectric pellets. These partial electrical discharges can enhance partial discharges around the surface of ferroelectric pellets. This method utilizes wide reacting area of ferroelectric pellets and partial discharge. Positive and negative dc voltage are applied to the corona tip to generate partial discharges, and corona currents are estimated to investigate charge storage on ferroelectric pellets as function of time and charge relaxation time constants of ferroelectric pellects. As a result, charge relaxationtime, dielectric constants of ferroelectric pellets, polarity of applied voltage and applied time influence partial discharges among ferroelectric pellect.

  • PDF

고체유전체에서 발생한 부시형 전기트리에 수반된 내부 부분방전 펄스 해석 (Internal PD Pulses Analysis Accompanying with Bush-type Tree in Solid Dielectrics)

  • 강성화;홍현문;류부형
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.100-105
    • /
    • 2000
  • Correlation between propagation of bush-type electrical tree and internal partial discharges(PD) was discussed. We used specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope interfaced with computer and investigated characteristics of phase resolved PD pulses accompanying with propagation of electrical tree. Electrical tree generally growed bush-type tree. PD data detected and analyzed were average discharge current and statistical operator of q-n, $\psi$- $q_{avg}$, $\psi$-n, ${\psi}-q_{max}$ distribution. Parameters used were skewness, kurtosis, average discharge phase, cross-correlation factor, asymmetry and etc. In generally, average discharge current had good linear relationship with propagation of bush type electrical tree on this experiment. Peak discharge magnitude and repetition rate were increased, but they had not good linear relationship.p.

  • PDF

PDP용 CuN/Cu/CuN 전극재료의 개발에 관한 연구 (Development of the CuN/Cu/CuN type Electrode Material for the PDP)

  • 성열문;정신수;류재하;김재성;조정수;박정후
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.55-58
    • /
    • 1996
  • A new type CuN/Cu/CuN thin film electrode material with high adhesion to glass was developed by the dc reactive planar magnetron sputtering system for the PDP(Plasma Display Panel). The adhesive force of the CuxN thin film was in the range of 20∼40(N) under the conditions of the N$_2$ partial pressure of 15%, discharge current of 70mA, discharge voltage of 450v and substrate bias voltage of -100V. The adhesive force was depended on the N$_2$ partial Pressure, discharge current and substrate bias voltage.

  • PDF

PDP용 CuN/Cu/CuN 전극재료의 개발에 관한 연구 (A Study on Developement of CuN/Cu/CuN Electrode Material for PDP)

  • 조정수;박정후;성열문;정신수;석복렬;류주연;김준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1572-1575
    • /
    • 1996
  • A new type $Cu_{x}N/Cu/Cu_{x}N$ thin film electrode material with high adhesion to glass was developed by the dc reactive planar magnetron sputtering system for the PDP(Plasma Display Panel). The adhesive force of the $Cu_{x}N$ thin film was in the range of $20{\sim}40(N)$ under the conditions of the $N_2$ partial pressure of 15%, discharge current of 70mA, discharge voltage of 450V and substrate bias voltage of -100V. The adhesive force was depended on the $N_2$ partial pressure, discharge current and substrate bias voltage.

  • PDF

몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작 (Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers)

  • 이경렬;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제35권6호
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.

New Address Electrode Suitable for Fast Addressing with High Xe ac-PDP

  • Lee, Don-Kyu;Lee, Ho-Jun;Lee, Hae-June;Kim, Dong-Hyun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.564-567
    • /
    • 2004
  • New address electrode having separated dual electrode is suggested to reduce addressing time in ac PDP. Addressing characteristics of suggested electrode has been investigated in the test panel with high Xe partial pressure. It has been found that both the formative and jitter width of the suggested electrode is improved by 10 -20 % over the wide range of address voltage level compared with the conventional one. The dynamic margin of the panel also greatly improved. The key feature behind this type of structure is that it can extend the controllability of the wall charge distribution during the reset and address discharge without significant increase in capacitive load of address electrode.

  • PDF