검색결과 98건 처리시간 0.026초

변압기내 부분방전 탐지 및 위치검출 (Detection and Location of Partial Discharge in Transformers)

  • 곽희노;김재철;황선주;권태원;윤용범
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권4호
    • /
    • pp.53-59
    • /
    • 1992
  • This paper describes an instrument for the detection and geometric location of partial discharge (PD) source in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulses and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used for detecting and locating PD in the transformer.

  • PDF

초음파 신호를 이용한 부분방전 검출 장치 개발에 관한 연구 (Implementation for Partial Discharge Detection using Ultrasonic Signal)

  • 최수안;정형호;곽희로;김재철;정상진;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.588-590
    • /
    • 1993
  • This paper presents a diagnostic technique using ultrasonic for operating power transformer. Two methods are used as a base for detecting a partial discharge. One is a analysis of PD trend using counted ultrasonic signal, the other is a estimation of PD location source using cross-correlation. In this paper we implement detection equipment of partial discharge in power transformer. The desired system is utilized to two methods for PD detection and operated by graphical user interface(GUI). The results of test showed that the system can be adopted to real power transformer.

  • PDF

GIS 감시진단용 다양한 센서를 적용한 PD 검출 및 패턴분석 결과 비교연구 (A Comparate Study for the PD Pattern Analysis using Different Type of Sensors Applicable to the On-line Monitoring of GIS)

  • 구자윤;장용무;최재옥;연만승;이지철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.198-205
    • /
    • 2005
  • Many precedent investigations hate been made for the reliable assessment of the insulation state of large power apparatus for which partial discharge detection is one of tile plausible way. In this work, experimental investigations have been carried out to make the comparison on the PD(partial discharge) pattern analysis related to the five different types of artificial defects such as SFMP (Single Free Moving Particle), MFMP (Multi Free Moving Particle), Void, CFP (Conductor-Fixed Protrusion), EP (Enclosure Protrusion). For each PD pattern, PD detection has been done by tee different types of PD sensors such as HFCT(High Frequency Current Transformer), AE(Acoustic Emission) and UHF(Ultra High Frequency). And, in addition, frequency spectrum by the UHF sensor has been also made for each defect respectively. As a result, it is observed that the possibility of obtaining PD pattern based on PRPD(Phase Resolved Partial Discharge) in connection with the defects tinder investigation is dependant on the type of the sensor while the spectrum analysis is always successful to be achieved for every defect. Therefore, it could be suggested that the nature of PD source can be identified more distinctively when the conventional PRPDA is combined with spectrum analysis.

UWB 안테나를 이용한 MV급 전력케이블의 부분방전 측정 연구 (PD measuring on MV XLPE Calble by Using UWB Antenna)

  • 양상현;임광진;이용성;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.267-268
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band(UWB) sensor design and studying of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with new designed UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both low frequency and high frequency band of partial discharge signal. And experiments of offline PD testing on in medium voltage (22.9kV) underground cable and mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative test, the calibration signal injection test provided with conventional IEC 60270 method and high voltage injection testing are included.

  • PDF

The Design and Experiment of a Planar Patch Sensor for Partial Discharge Diagnostics in 6.6 kV Rotating Machine Stator Windings

  • Yang, Sang-Hyun;Park, Noh-Joon;Park, Dae-Hee;Kim, Hee-Dong;Lim, Kwang-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권5호
    • /
    • pp.173-176
    • /
    • 2009
  • In the stator windings of a 6.6 kV rotating machine, internal discharges, slot discharges, and surface discharges are mainly caused by internal voids and insulation degradation. If a partial discharge(PD) occurs in an inner-part of the stator windings, it will cause electromagnetic pulses with wide frequency ranges. Discharge sparks and electromagnetic pulses generated from a discharge source, can be detected using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, a planar patch sensor was designed and fabricated using a CST-MWS simulation, and PD signals from an artificially defected stator winding were also measured by the sensor proposed in this study. Furthermore, an HFCT was used as a reference sensor and compared with the proposed new planar patch sensor. In the results of the experiment, the planar patch sensor showed a similar performance to the HFCT sensor.

초광대역과 단일주파수(협대역) UHF 부분방전 검출기법 비교 (Ultra-wide bandwidth versus narrow bandwidth PD detection techniques for UHF partial discharge monitoring system)

  • 박기준;구선근;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1655-1657
    • /
    • 2002
  • Ultra-wide bandwidth (UWB), narrow bandwidth (single frequency), and a combination of both technologies have been studied for the ultra-high frequency (UHF) partial discharge (PD) monitoring system as a detection scheme. We have experimentally compared those detection methods using a mock-up of 362 kV class single phase gas-insulated switchgear (GIS) and a stable PD source. A rolling-ball type PD cell that produces PDs of about 10 pC, is placed at one end of the GIS. An internal UHF PD sensor was attached several meters away from the PD source. The PD spectrum was measured up to 3 GHz. A useable bandwidth of more than 1 GHz was used to measure UWB signals from the PD. To simulate the narrow bandwidth scheme a bandwidth of 100 kHz centered at several different frequencies was used.

  • PDF

유입 변압기에서 폴디드 다이폴형 센서의 부분방전 펄스 검출 특성 (The Detection Characteristics of the Partial Discharge Pluses with Folded Dipole Type Sensors in the Oil Transformers)

  • 김광화;이상화;선종호;강동식;김재철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권10호
    • /
    • pp.485-491
    • /
    • 2006
  • This paper describes that the distribution of electromagnetic field occurred by PD(Partial Discharge) pulse was calculated with simulation program and characteristics of calibration and PD pulses measured with folded dipole types sensors were analyzed. As the distribution of electromagnetic field in simulation was very random the wide band measuring methods were good. Therefore three folded dipole antenna types sensors which had different their widths were designed and made. The signal according to direction and distance between sensor and pulse source in these sensor was measured and the spectrum of surface PD were acquired in the experiment of model transformer. In this result the characteristics of sensor which had middle width was better than others and the main spectrum of PD signals in surface discharge were existed in around 220MHz, 320MHz and from 450MHz to 750MHz.

가스절연 개폐장치의 내부절연 성능검증을 위한 UHF 협대역 부분방전 진단법 (UHF Narrow Band Type Partial Discharge Diagnosis Method for the Internal Insulation Performance Verification of the Gas Insulated Switchgear)

  • 송원표;김정배;김민수;정재룡;박승재;고희석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.414-420
    • /
    • 2005
  • A method for partial discharge diagnosis based on UHF narrow band type for GIS has been developed and calibrated. In generally, PD cannot be directly measured under on-line condition, but we can indirectly measure the electromagnetic wave made by PD using the high-frequency antenna. Compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise in high-voltage substation. Therefore, we can detect the real abnormality with several pC in GIS using UHF narrow-band type method. For the case of no internal VHF sensor for GIS of the domestic substation, it has applied to use the external UHF sensor attached in spacer in GIS of existing substation. In this paper, we firstly described the technique of partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity test, the relationship of dBm-pC and diagnosis result of the cause of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on the real GIS in domestic substation. These results make above method applicable for measurement of quantity and cause of PD for real operation GIS in high-voltage substation.

광대역 및 협대역을 동시에 사용하는 부분방전 측정 시스템 모듈 개발 (Development of Partial Discharge Measuring System Module by use of Wide and Narrow Band)

  • 이종오;유경국;신인권;장덕진;안창환
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.98-103
    • /
    • 2015
  • Power plant is that very high reliability when industrial and economic impact on the overall electric power system is required, it is essential to improve the reliability, especially the fault prediction diagnosis. Since an accident caused by the partial discharge in the power plant is above state has a faster response characteristic than the other indications in the case of any, the partial discharge generated in the power plant immediately detect the deterioration of insulation due to the accident of the power plant and the non-drawn It should prevent or reduce. Partial Discharge Measuring Systems for UHV SF6 Gas Insulated Switchgear and power transformer on site installed has some probability of abnormal recognition in case of non-flexible deal with on site noise. Many methode to eliminate these kinds of noises, UHF Detection System is chosen as purchase description in Korea, but this system having a bandwidth between 500MHz 1.5GHz wide band. Initial install periods(about 20 years ago), this band had no strong signal source, but in these days this wide band have strong signals, such as LTE. So, module described in this paper is designed as simultaneously use with wide and narrow band for solve this noise problem, and introduce this system.

N형 실리콘 제어 정류기 소자의 구조 변형을 통한 정전기 보호성능의 향상에 대한 연구 (Improvement of Electrostatic Discharge (ESD) Protection Performance through Structure Modification of N-Type Silicon Controlled Rectifier Device)

  • 양준원;서용진
    • 한국위성정보통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.124-129
    • /
    • 2013
  • PPS 구조가 삽입된 N형 실리콘 제어 정류기 소자를 마이크로 칩의 고전압 I/O 응용을 위해 연구하였다. 종래의 NSCR_PPS_Std 표준소자는 매우 낮은 스냅백 홀딩 전압을 갖는 전형적인 SCR 특성을 가지고 있어 정상적인 동작 동안 래치업 문제가 나타나는 것으로 보고되고 있다. 그러나 본 연구에서 제안하는 CPS 및 부분적으로 형성된 P-Well(PPW) 구조를 갖는 변형된 NSCR_PPS_CPS_PPW 소자는 높은 래치업 면역과 트리거링 전압의 조절이 용이한 안정한 ESD 보호 성능을 나타내어 고전압 동작용 마이크로 칩의 정전기보호 소자로 적용 가능함을 확인하였다.