Power plant is that very high reliability when industrial and economic impact on the overall electric power system is required, it is essential to improve the reliability, especially the fault prediction diagnosis. Since an accident caused by the partial discharge in the power plant is above state has a faster response characteristic than the other indications in the case of any, the partial discharge generated in the power plant immediately detect the deterioration of insulation due to the accident of the power plant and the non-drawn It should prevent or reduce. Partial Discharge Measuring Systems for UHV SF6 Gas Insulated Switchgear and power transformer on site installed has some probability of abnormal recognition in case of non-flexible deal with on site noise. Many methode to eliminate these kinds of noises, UHF Detection System is chosen as purchase description in Korea, but this system having a bandwidth between 500MHz 1.5GHz wide band. Initial install periods(about 20 years ago), this band had no strong signal source, but in these days this wide band have strong signals, such as LTE. So, module described in this paper is designed as simultaneously use with wide and narrow band for solve this noise problem, and introduce this system.

Keywords

References

  1. C.J.Lee, W.J.Kang, H.C.Lee, J.W.Park, "A study on the UHF PD measurement for the HV apparatus", Joint conference of ACED & KJ symposium on ED and HVE, pp. 223-226, 2002.
  2. Nicholas de kock, Branko Coric and Ralf Pietsch, "UHF PD detection in gas insulated switchgear-suitability and sensitivity of the UHF method in comparison with the IEC 270 method", IEEE Electrical insulation magazine, Vol. 12, No. 6, pp. 20-26, 1996. https://doi.org/10.1109/57.546277
  3. M. D. Judd, O. Farish, B. F. Hampton, "The excitation of UHF signals by Partial discharges in GIS", IEEE Trans. On Dielectrics and Electrical Insulation, Vol. 3, No. 2, pp.213-228, 1996. https://doi.org/10.1109/94.486773
  4. W.R.Rutgers, R.Ross adn T.G.M Rijn, "On-line PD detection techniques for assessment of the dielectric condition of HV components", pp. 481-484, 7th ICSD, 2001.
  5. E. Gulski, S. Meijer, W.R. Rutgers, R. Brooks, "Recognition of PD in $SF_6$ Insulation Using Digital Data Processing", IEEE Annual Report-Conference on Electrical Insulation and Dielectric Phenomena, San Francisco, pp.577-580, October 20-23, 1996.
  6. CIGRE Task Force 15/33/03.05 of working group 15.03, "Partial discharge detection system for GIS: sensitivity verification for the UHF method and the acoustic method", Electra, No. 183, pp. 75-87, 1999.
  7. Gulski, S. Meijer, W.R. Rutgers, R. Brooks, "Recognition of PD in $SF_6$ Insulation Using Digital Data Processing", IEEE Annual Report-Conference on Electrical Insulation and Dielectric Phenomena, San Francisco, pp.577-580, October 20-23, 1996.
  8. I.Gallimberti, G.. Marchesi and R. Turri, "Corona formation and Propagation in Weakly and Strongly Attaching Gases", 8thInternat.Conf.OnGasDischarges,Oxford,pp.587-594, 1985.
  9. Paul C. Werntz, Warren L. Stutzman, "Design, analysis and construction of an Archimedean spiral antenna and feed structure", Southeastcon '89. proceedings, 'Energy and information technologies in the southease'. IEEE, vol. 1, pp. 308-313, 1989.
  10. R.E. James and B.T. Phung, "Development of Computer-based Measurements and their Application to PD Pattern Analysis", IEEE Trans. on Dielectrics and Electrical Insulation, vol. 2, no. 5, pp.838-855, 1995. https://doi.org/10.1109/94.469978