• Title/Summary/Keyword: Partial Field

Search Result 932, Processing Time 0.029 seconds

Analysis of the Pressure Distribution for Press Shoe considering Partially Changed Curvature of Bearing Surface

  • Park, Sang-Shin;Park, Young-Ha;Lee, Young-Ze;Han, Man-Cheol
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.123-124
    • /
    • 2002
  • A press shoe is an element of a machine for squeezing water from wood pulp in the field of manufacturing paper. This is used to compress the pulp enveloped by felt sheet with a large roller. The squeezing force is made by hydraulic pressure. The press shoe has a mechanism similar to a partial hydrostatic bearing. The pressure profile between press shoe and roller affects their squeezing ability, and partial peak pressure can tear the wet pulp. The curvature of the surface of press shoe varies to reduce the peak pressure and increase the mean pressure simultaneously. Therefore, the prediction of pressure distribution considering partially changed curvature of hydrostatic bearing is very important for designing the press shoe. In this study, the difference formulation of Reynolds' equation for partial hydrostatic bearing is by direct numerical method and a computer program to calculate the pressure distribution is developed. We investigate the effect of partially changed curvature of bearing surface on the pressure distribution. Other design parameter for hydrostatic bearing such as depth of pocket and relative velocity are also studied.

  • PDF

Features Extraction and Mechanism Analysis of Partial Discharge Development under Protrusion Defect

  • Dong, Yu-Lin;Tang, Ju;Zeng, Fu-Ping;Liu, Min
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.344-354
    • /
    • 2015
  • In order to study the development of partial discharge (PD) under typical protrusion defects in gas-insulated switchgear, we applied step voltages on the defect and obtained the ${\varphi}-u$ and ${\varphi}-n$ spectrograms of ultra-high frequency (UHF) PD signals in various PD stages. Furthermore, we extracted seven kinds of features to characterize the degree of deterioration of insulation and analyzed their values, variation trends, and change rates. These characteristics were inconsistent with the development of PD. Hence, the differences of these features could describe the severity of PD. In addition, these characteristics could provide integrated characteristics regarding PD development and improve the reliability of PD severity assessment because these characteristics were extracted from different angles. To explain the variation laws of these seven kinds of parameters, we analyzed the relevant physical mechanism by considering the microphysical process of PD formation and development as well as the distortion effect generated by the space charges on the initial field. The relevant physical mechanism effectively allocated PD severity among these features for assessment, and the effectiveness and reliability of using these features to assess PD severity were proved by testing a large number of PD samples.

A Study on the Nozzle-Rotor Interactions of Partial Admission Supersonic Turbines (부분입사형 초음속 터빈의 노즐과 익렬의 상호작용에 관한 연구)

  • Seong Young-Sik;Han Seong-Hoon;Kim Kui-Soon;Park Chang-Kyoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.3
    • /
    • pp.53-60
    • /
    • 2004
  • In order to investigate the nozzle - rotor interactions and the effect of partial admission, the flows in supersonic turbine rotor cascades with a nozzle have been computed. Extensive computations of partial admission supersonic turbines provide the shock structures and flow patterns in the nozzle and rotor. The governing equations were discretized with Euler implicit method in time and 2nd-order upwind scheme of FVM in space. The $\kappa$-$\varepsilon$ turbulence model was utilized to describe the turbulent flow field. It is clearly shown that the nozzle flow is highly affected by the shocks or expansion waves propagated from the rotor leading edge. And the rotor flow is also affected by the shocks or wakes originated from the nozzle.

Analysis of the Pressure Distribution for Press Shoe considering Partially Changed Curvature of Bearing Surface

  • Park, Sang-Shin;Park, Young-Ha;Lee, Young-Ze;Han, Man-Cheol
    • KSTLE International Journal
    • /
    • v.3 no.2
    • /
    • pp.90-94
    • /
    • 2002
  • A press shoe is an element of a machine for squeezing water from wood pulp in the field of manufacturing paper. This is used to compress the pulp enveloped by felt sheet with a large roller. The squeezing farce is made by hydraulic pressure. The press shoe has a mechanism similar to a partial hydrostatic bearing. The pressure profile between press shoe and roller affects their squeezing ability, and partial peak pressure can tear the wet pulp. The curvature of the surface of press shoe varies to reduce the peak pressure and increase the mean pressure simultaneously, Therefore, the prediction of pressure distribution considering partially changed curvature of hydrostatic bearing is very important far designing the press shoe. In this study, the difference formulation of Reynolds equation far partial hydrostatic bearing is derived by direct numerical method and a computer program to calculate the pressure distribution is developed. We investigate the effect of partially changed curvature of bearing surface on the pressure distribution. Other design parameter far hydrostatic bearing such as depth of pocket and relative velocity are also studied.

Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings (13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석)

  • Chang, Jeong-Ho;Lee, Dong-Keun;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

The Frequency Characteristics of Radiated Electromagnetic Waves in accordance with AC Discharge Progress in Liquid Nitrogen (액체질소중 교류방전 진전에 따른 방사전자파 주파수 특성)

  • Park, Kwang-Seo;Lee, Sang-Hun;Ju, Jea-Hyun;Choi, Byoung-Ju;Kim, Ki-Chai;Park, Won-Zoo;Do, Dae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1975-1977
    • /
    • 2000
  • In this study, a relationship between AC discharge progress and the radiated electromagnetic waves were investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The characteristics of frequency spectrum of the radiated electromagnetic waves was measured at the atmospheric pressure in liquid nitrogen($LN_2$) during partial discharges progress in nonuniform electric field depend on AC power supply. From this results, it was confirmed that when partial discharge was produced in liquid nitrogen, the signal of partial discharge was detected by frequency spectrum of the radiated electromagnetic waves. It is considered that these results obtained from this investigation may be used as fundamental data for diagnosis and prediction of insulation on superconducting and cryogenic power equipments.

  • PDF

Partial thyrotomy (갑상연골 부분절개술)

  • 이종원;김성남;김성곤;권영찬;양한모
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.10.2-10
    • /
    • 1977
  • Thyrotomy is very useful surgical procedure for laryngeal lesions; however, the web-formation at the anterior part of vocal cords is a frequent troublesome sequel of this procedure. Since the anterior commissure is not injured in Hayashi's hemithyrotomy, a web never results from this procedure. But the intralaryngeal exposure is too small to perform the surgery in this method. Partial thyrotomy was deviced as a new surgical technique to the glottic subglottic lesion. In partial thyrotomy, surgical procedure can be easily carried out under local anesthesia, in a wide field. This procedure has no side effects such as the web-formation at the anterior commissure, nor dyspnea after the surgery.

  • PDF

Assessment of 23 kV Capacitive Coupler for On-line Partial Discharge Measurements

  • Jeong, J.Y.;Kang, D.S.;Sun, J.H.;Heo, J.C.;Park, C.H.
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.123-130
    • /
    • 2009
  • The partial discharge (PD) measurement is a very effective method to assess the winding insulation condition of high-voltage machines, since most of the insulation failure processes are directly or indirectly caused by PD. On-line PD measurements, which can detect insulation defects of winding in the early stages on rotating machines in operation, have been accepted as the most important technique. The epoxy mica capacitive coupler is currently and extensively used for on-line detection of PD pulses of high-voltage rotating machines. To evaluate the feasibility of developing a capacitive coupler that is easier to manufacture at a lower cost compared to epoxy mica couplers, a 100pF capacitive coupler made of ceramic material is designed, fabricated and tested for on-line PD measurements of 23 kV electrical machines. A series of electrical tests and accelerated aging tests are performed on the ceramic coupler to evaluate the performance requirements, long-term reliability and thermal stability for in field application. The test results show that the newly developed ceramic coupler provides equal and improved performance at a lower cost compared to epoxy mica couplers, and estimated voltage life is anticipated to surpass 100 years.

Partial Discharge Characteristics of XLPE According to Electrode Shape and Void (전극형상 및 보이드에 따른 XLPE의 부분방전 특성)

  • Shin, Jong-Yeol;Kim, Guin-sik;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.50-57
    • /
    • 2016
  • Transmission equipment is mainly used for the XLPE (cross-linked polyethylene) insulation cable for ultra high voltage power to minimize power loss. The experiment examined the partial discharge characteristics according to the insertion of the bar electrode and needle electrode into the XLPE specimen and the air voids. XLPE insulation cable manufactured by T. company and tungsten electrode material by K. company were used for specimens, by adhering conductive tape on the semi-conductive material of the lower electrode of XLPE specimen with the dimension of $16{\times}40{\times}30$ [mm] was used as negative electrode. In order to investigate the PD with ${\phi}$-q-n of XLPE specimen according to the electrode shape and the size of air voids. we examined the PD by varying the voltage after applying voltage of 3~20 kV on the electrode. Therefore, it was confirmed from the result of PD characteristics of specimen that the larger the air void than the gap between electrode (+) and electrode(-), the larger effect on the discharge when the bar electrode and needle electrode inserted into XLPE, and the closer the distance between the insulation and the needle electrode, the faster insulation breakdown.

Analysis of the Temperature Influence on Insulation Characteristics in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 온도변화에 따른 절연특성 분석)

  • Kong, Tae-Sik;Ju, Young-Ho;Kim, Hee-Dong;Park, Tae-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.786-790
    • /
    • 2012
  • A variety of diagnostic tests are widely applied in the field in industry to evaluate the condition of high voltage (HV) motor stator insulation. In this paper, the influence of temperature on the stator insulation diagnostic tests such as the insulation resistance, AC current, dissipation factor, and partial discharge measurements are studied and reported. The tests are performed with the HV motor stator winding temperature set between $40^{\circ}C$ to $80^{\circ}C$ in $10^{\circ}C$ intervals. It is shown that the AC current, dissipation factor, and partial discharge magnitude steadily increase with temperature, which suggests that temperature must be taken into account in the interpretation of the test results.