• 제목/요약/키워드: Partial Discharge(PD)

검색결과 501건 처리시간 0.028초

Application of Fuzzy Algorithm for Partial Discharge Analysis

  • Kim, Jin-Su;Yeom, Keong-Tae;Kim, Kwan-Kyu;Kim, Ji-Hyoung
    • 한국정보전자통신기술학회논문지
    • /
    • 제1권3호
    • /
    • pp.119-125
    • /
    • 2008
  • This work involves analyzing partial discharge (PD), which has estimated the detected signal accumulation based on Labview, and analyzing by Fuzzy algorithm. In algorithm, we developed system configuration that detected accumulating PD signal. With practical PD logic implementation of theoretical detected system and hardware implementation, the device for 50kV setup has generated and then has applied with 15k~17kV with 1:1 time probe. Our new class of PD detected algorithm has also compared with PRPDA or Fuzzy algorithm, which has diagnose more conveniently by adding numerical values.

  • PDF

K-means 클러스터링을 이용한 케이블 접속재 계면결함의 부분방전 분포 해석 (Partial Discharge Distribution Analysis on Interlace Defects of Cable Joint using K-means Clustering)

  • 조경순;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제20권11호
    • /
    • pp.959-964
    • /
    • 2007
  • To investigate the influence of partial discharge(PD) distribution characteristics due to various defects on the power cable joints interface, we used the K-means clustering method. As the result of PD number(n) distribution analyzing on $\Phi-n$ graph, the phase angle($\Phi$) of cluster centroid shifted to $0^{\circ}\;and\;180^{\circ}$ increasing with applying voltage. It was confirmed that the PD quantify(q) and euclidean distance of centroid were increased with applying voltage from the centroid distribution analyzing of $\Phi-q$ plane. The dispersion degree was increased with calculated standard deviation of the $\Phi-q$ cluster centroid. The PD number and mean value on $\Phi-q$ graph were some different by electric field concentration with defect types.

CAPD기법을 이용한 부분방전 현상 해석에 관한 연구 (Analysis of Partial Discharge Phenomena by means of CAPD)

  • 김성홍
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.939-944
    • /
    • 2002
  • PD phenomena can be regarded as a deterministic dynamical process where PD should be occurred if the local electric field be reached to be sufficiently high. And thus, its mathematical model can be described by either difference equations or differential equations using several state variables obtained from the time sequential measured data of PD signals. These variables can provide rich and complex behavior of detectable time series, for which Chaos theory can be employed. In this respect, a new PD pattern recognition method is proposed and named as 'Chaotic Analysis of Partial Discharges (CAPD)' for this work. For this purpose, six types of specimen are designed and made as the models of the possible defects that may cause sudden failures of the underground power transmission cables under service, and partial discharge signals, generated from those samples, are detected and then analyzed by means of CAPD. Throughout the work, qualitative and quantitative properties related to the PD signals from different defects are analyzed by use of attractor in phase space, information dimensions ($D_0$ and D2), Lyapunov exponents and K-S entropy as well. Based on these results, it could be pointed out that the nature of defect seems to be identified more distinctively when the CAPD is combined with traditional statistical method such as PRPDA. Furthermore, the relationship between PD magnitude and the occurrence timing is investigated with a view to simulating PD phenomena.

  • PDF

Partial Discharge Characteristics in LLDPE-Natural Rubber Blends: Correlating Electrical Quantities with Surface Degradation

  • Aulia, Aulia;Ahmad, Mohd Hafizi;Abdul-Malek, Zulkurnain;Arief, Yanuar Z.;Lau, KwanYiew;Novizon, Novizon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.699-706
    • /
    • 2016
  • Partial discharges (PD) lead to the degradation of high voltage cables and accessories. PD activities occur due to the existence of impurities, voids, contaminants, defects and protrusions during the manufacture and installation of power cables. Commonly, insulation failures occur at cable joints and terminations, caused by inhomogeneous electric field distributions. In this work, a blend of natural rubber (NR) and linear low density polyethylene (LLDPE) was investigated, and the optimal formulation of the blend that could resist PD was discussed. The experiments were conducted under a constant high voltage stress test of 6.5 kV AC and the magnitude of partial discharge activities was recorded using the CIGRE method II. Pattern analysis of PD signals was performed along with the interpretation of morphological changes. The results showed that the addition of 10 wt% of NR and 5 wt% of Alumina Trihydrate (ATH) provided promising results in resisting PD activities. However, as the NR content increased, more micropores existed, thus resulting in increased PD activities within the samples.

PD 측정과 HFPD의 감도특성에 관한 연구 (A Study on the Sensitivities Characteristics in a PD and a HFPD)

  • 임장섭;김덕근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.29-32
    • /
    • 2000
  • The partial discharge testing is widely used in insulation property measurement because it gives low stress to high voltage equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power transformer that requires on-line & on-site diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and PD/HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구 (A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System)

  • 김성주;장석훈;조국희
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.

수력발전기 고정자 권선의 운전중 부분방전 특성 (Properties of On-Line Partial Discharge in Hydrogenerator Stator Windings)

  • 김병한;김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.172-177
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) tests were performed with partial discharge analyzer(PDA) in two hydrogenerators. Six cable couplers were installed in circuit ring bus and endwinding of three phases. PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude$(Q_m)$ were very low in hydrogenerator #1 and #2, respectively. The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in hydrogenerator stator windings. The insulation condition of stator winding can be assessed. Discharge at conductor surface was discovered in B phase(C2 coupler) of hydrogenerator #1. Internal discharges were generated in A and C phases(C2 coupler) of hydrogenerator #1 and in A, Band C phases(C1 and C2 couplers) of hydrogenerator #2. Slot discharges occurred in A, Band C phases(C1 coupler) of hydrogenerator #1. The stator windings of two hydrogenerators were in good condition.

Comparison of Partial Discharge Characteristics in SF6 Gas Under AC and DC

  • Jo, Hyang-Eun;Wang, Guoming;Kim, Sun-Jae;Kil, Gyung-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권6호
    • /
    • pp.323-327
    • /
    • 2015
  • In this paper, parameters related with partial discharge (PD) were analyzed in SF6 gas under AC and DC voltages. Three electrode systems (protrusion on conductor, protrusion on enclosure, and free particle) were fabricated to simulate PD defects in a gas-insulated switchgear (GIS). All electrode systems were filled with SF6 gas at 0.5 MPa. PD pulses were detected using an oscilloscope and a data acquisition (DAQ) based on IEC 60270. To analyze the PD characteristics under AC and DC voltages, parameters such as discharge inception voltage (DIV), discharge extinction voltage (DEV), pulse magnitude, repetition rate, and T-F map were compared. From the experimental results, PD was revealed to have different characteristics under AC and DC, and these results may be useful for diagnosis of power facilities operated under HVDC.

3상 전력케이블 크로스본딩 접속에서 부분방전 펄스 전파 특성 고찰 (Considerations on the Propagation of Partial Discharge Pulse in 3-Phase Power Cable Systems including Cross-Bonding Joints)

  • 김정태;김동욱;김지홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1606-1607
    • /
    • 2011
  • In this study, the propagation characteristics of partial discharge(PD) pulses in the 3-phase cable systems including crossbonding joints were discussed. For the purpose, experiments for 22.9kV CNCV cables were performed using simulated PD pulses, and on-site partial discharge measurements were carried out for the 345kV XLPE cable system.

  • PDF

지중 송전케이블 PD진단 기술 현황 및 정확도 향상방안 검토 (Present Status and Accuracy Improvement Plan on Partial Discharge Diagnosis Technology for Underground Transmission Cable)

  • 장태인;강연욱;강지원;김종채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.537-538
    • /
    • 2011
  • 본 논문은 지중송전 XLPE 케이블에 대한 국내외 부분방전(Partial Discharge) 진단기술 현황과 정확도 향상방안을 다룬다. 먼저, 최근의 국내 XLPE 케이블 설치 및 고장 현황을 살펴보고, 국내외 PD진단 동향, PD 진단장비의 특징, 접속부 계면 PD의 주파수 특성을 차례로 알아본다. 마지막으로 이를 종합하여 진단 정확도 향상 방안 및 케이블 고장예방을 위한 향후 연구방향을 제시한다.

  • PDF