• Title/Summary/Keyword: Part Disconnection

Search Result 36, Processing Time 0.027 seconds

Research about point adhesion disconnection type non-exposure composition waterproof method of construction development that use embossing PVC sheet (엠보싱 PVC 시트를 이용한 부분절연(部分絶緣) 블록형 옥상(屋上) 비노출 복합방수(複合防水)공법 개발(開發)에 관(關)한 연구(硏究))

  • Wi, Tae-Hwan;Kang, Hyo-Jin;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.37-40
    • /
    • 2003
  • This present paper mainly contains adhesion part disconnection type exposure composition waterproof method using embossing PVC sheet. The existing polymer resin coating and sheet waterproofing construction method have, however, some weak point such as being decrease life cycle of concrete with water leaking from materials be affected by crack and movement dash bond concrete through the whole-adhere construction. Above the reason, this paper has particular method increasing crack-defending performance from stress occurred concrete movement by part disconnection, adds maintain waterproofing performance subordinate sheet, that can be contributed a convenience of maintenance which is decreasing industrial waste and repair construction cycle through the part repair in case of leaking water.

  • PDF

Research about point adhesion disconnection type non-exposure composition waterproof method of construction development that use embossing PVC sheet (엠보싱 PVC 시트를 이용한 부분절연 블록형 옥상 비노출 복합방수공법 개발에 관한 연구)

  • 위태환;강효진;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.37-40
    • /
    • 2003
  • This present paper mainly contains adhesion part disconnection type exposure composition waterproof method using embossing PVC sheet. The existing polymer resin coating and sheet waterproofing construction method have, however, some weak point such as being decrease life cycle of concrete with water leaking from materials be affected by crack and movement dash bond concrete through the whole-adhere construction. Above the reason, this paper has particular method increasing crack-defending performance from stress occurred concrete movement by part disconnection, adds maintain waterproofing performance subordinate sheet, that can be contributed a convenience of maintenance which is decreasing industrial waste and repair construction cycle through the part repair in case of leaking water.

  • PDF

Design and implementation of ESD cable Disconnection Monitoring System (ESD 접지선 단선 모니터링 시스템 설계 및 구현)

  • Seong, Jung-Mo;Chung, Young-Suk;Park, Koo-Rack
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.77-82
    • /
    • 2017
  • In the splay manufacturing process, conveyor systems are widely used for conveying panels. In this conveyor, a large number of grounding lines are used in order to prevent a product failure due to static electricity. In many cases, the grounding line is disconnected due to the rotation of the transporting roller or curling, leading to product failure. In order to solve such a problem, there is a growing need for a system capable of detecting disconnection of a ground wire in real time. Therefore, in this paper, we propose a disconnection monitoring system of ESD (Electro-Static Discharge) ground wire caused by friction between the conveyor drive part and the panel. The proposed system is a monitoring system that can detect disconnection and disconnection of ground wire using ATmega 2560 and Wheatstone Bridge circuit. It can detect disconnection of ground wire immediately and can take measures to reduce the defect rate due to static electricity. The system proposed in this paper is expected to be applicable to the production and test equipments of all industries where the ground wire is used.

Fault Diagnosis Device for Fire Prevention of the Resistance Heating Type three-Phase Electric Heater (3상 저항가열식 전기히터의 화재예방을 위한 결함 진단장치)

  • Lee, Mun-Hyung;Kim, Chan-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1669-1674
    • /
    • 2017
  • In this study, We have discussed the development of a diagnostic device to detect and prevent electrical fire due to the arc caused by contact failure and partial disconnection at the connection part of the three-phase electric heater wiring used in the industrial field. The arc caused by contact failure and partial disconnection at the connection part of the electric heater shows a change in the current effective value. Therefore, it is possible to determine whether there exists a defect by analyzing the current unbalance factor and the number of current fluctuations with the diagnostic apparatus. The three-phase unbalanced heater is considered to be capable of determining defects through periodic measurement and trend analysis of the current unbalance factor. It is also expected that this device can be used not only for electric heaters but also for detection of defects in wiring and connections of electrical equipment having a characteristic of constant load current.

Analysis of Thermal Characteristic for Wiring at Heater Connector of Semiconductor Chiller Equipment (반도체 공정 칠러 장비의 히터 접속부 전기배선에 대한 열적 특성 분석)

  • Gyu Bin Kim;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.27-34
    • /
    • 2023
  • With the technological development of the semiconductor industry, the roles of electrical and thermal energy supply and control of semiconductor equipment in ultrafine processes have become very important. However, instances of electrical fires in the chiller heater, which is used for cooling in the semiconductor manufacturing process, are increasing. A fire occurs in combustibles due to high heat at the connection part of the chiller heater, that is, when the number of electrical wires in the connection part is reduced or when the wires are completely disconnected. In this study, the temperature characteristics were compared and analyzed through experiments and 3D simulations. The number of electrical wires, which is the connection part of the chiller heater, was reduced by 90%, 50%, 30%, 10%, and 5%, and the wires were completely disconnected. When the number of electrical wires was reduced by 5%, heat of up to 80℃ was generated, which is a relatively high temperature but insufficient to cause a fire in combustibles. Complete disconnection occurred due to the vibration of the motor and other components, and sparks and arcs were generated, resulting in a rapid increase in temperature to up to 680℃. When completely disconnected, the temperature increase was sufficient to cause a fire in the combustibles covering the terminal block. Therefore, in this study, the causes of electrical fires in chiller heaters were investigated and preventive measures were proposed by analyzing abnormal signals and thermal characteristics caused by the electrical wiring being reduced and completely disconnected.

Study of Fire Appraisal Method According to Electrical Fire Hazards of Hair Dryer (모발건조기의 전기화재 위험요소에 따른 화재 감정기법 연구)

  • Moon, Hyun-Wook;Lee, Ki-Yeon;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.113-118
    • /
    • 2011
  • In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.

Possessions for Me, Experiences for Others: Preferred Gift Type in Gift-giving Behavior for Self or Others and a Moderate Effect of Emotional Disconnection Level (나를 위한 소유, 타인을 위한 경험: 나 vs 타인을 위한 선물 유형의 차이와 감정적 단절의 조절 효과)

  • Rim, Hye Bin;Kim, Seung Hwan;Doh, Eun Yeong;Lee, Byung-Kwan
    • Science of Emotion and Sensibility
    • /
    • v.23 no.2
    • /
    • pp.89-102
    • /
    • 2020
  • Consumers purchase gifts for themselves and for others. This research examined whether one's preferred purchase type (material or experiential) would depend on the gift recipient (self or others). A total of 200 participants took part in online studies via Amazon Mechanical-Turk. Based on the construal-level theory, people will focus on concrete product attributes for psychologically close objects; however, for psychologically distant objects, people will concentrate on abstract product attributes. Study 1 demonstrated that participants preferred material over experiential purchases in self-gifting situations, while they preferred experiential compared to material gifts for others. In Study 2, it was found that individual differences in emotional disconnection moderated the effect of gift recipient on preferred gift type. Specifically, the differences in preferred gift type increased as one's emotional disconnection level increased. The results of this research have theoretical implications in terms of extending construal-level theory to gift-purchasing behaviors. Furthermore, this research has practical implications for marketers and advertisers. Limitations and possible future research directions were also discussed.

The establishment of Proactive Routing Selection and Maintenance Algorithms for Mobile Ad Hoc Networks (이동 Ad Hoc 네트워크에서 사전 활성화 라우팅 선택과 관리유지 알고리즘의 구축)

  • Cho, Young-Joo;Lee, Yeo-Jin;Chung, Il-Yong
    • The KIPS Transactions:PartC
    • /
    • v.14C no.1 s.111
    • /
    • pp.73-80
    • /
    • 2007
  • In conventional on-demand mobile ad hoc routing algorithms, an alternate path is sought only after an active path is broken. It incurs a significant cost in terms of money and time in detecting the disconnection and establishing a new route. In this thesis, we propose proactive route selection and maintenance to conventional mobile ad hoc on-demand routing algorithms. The key idea for this research is to only consider a path break to be likely when the signal power of a received packet drops below an optimal threshold value and to generate a forewarning packet. In other words, if a path is lost with high probability, the neighboring node that may easily be cut off notifies the source node by sending a forewarning packet. Then the source node can initiate route discovery early and switched to a reliable path potentially avoiding the disconnection altogether. For the simulational study, network simulator(NS2) is used. The result of simulation shows that the algorithm significantly improves the performance of networks comparing to conventional on-demand routing protocols based on DSR and AODV in terms of packet delivery ratio, packet latency and routing overhead.

A Recovery Scheme of Mobile Transaction Based on Updates Propagation for Updating Spatial Data (공간데이터를 변경하는 모바일 트랜잭션의 변경 전파 회복 기법)

  • Kim, Dong-Hyun;Kang, Ju-Ho;Hong, Bong-Hee
    • Journal of Korea Spatial Information System Society
    • /
    • v.5 no.2 s.10
    • /
    • pp.69-82
    • /
    • 2003
  • Mobile transactions updating spatial objects are long transactions that update local objects of mobile clients during disconnection. Since a recovered transaction cannot read the write sets of other transactions committed before the recovery due to disconnection, the recovered transaction may conflicts with them. However, aborting of the recovered long transaction leads to the cancellation of all updates including the recovered updates. It is definitely unsuitable to cancel the recovered updates due to the conflicts. In this paper, we propose the recovery scheme to retrieve foreign conflictive objects from the write sets of other transactions for reducing aborting of a recovered transaction. The foreign conflictive objects are part of the data committed by other transactions and may conflict with the objects updated by the recovered transaction. In the scheme, since the recovered transaction can read both the foreign conflictive objects and the recently checkpoint read set, it is possible to reupdate properly the potentially conflicted objects.

  • PDF

Analysis on Momentary Voltage Dips with the Interconnection Operation of Utility-interactive Cogneration Systems Considering Their Generator Type (발전기 형태를 고려한 열병합발전시스템의 배전계통 연계운전시의 순시전압변동 해석)

  • 최준호;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.23-30
    • /
    • 2000
  • Cogeneration systems are seen as a significant innovation for dispersed energy generation since they are both environmentally friendly and has comparatively high degrees of efficiency. It is especially suited for the decentralized provision of electricity and heat. However, it causes operational problems such as voltage regulation, voltage variation, protection and safety. Especially, it is expected that the interconnection/disconnection operation of cogeneration system has an effect on distribution voltage regulation and variation. Recently, with the increased use of customer-owned computers and other sensitive electronic equipment, electric power quality has become an important concerns. Therefore, the voltage quality problems with cogeneration system should be investigated because the voltage quality is an important part of electrical power quality. In this paper, the momentary voltage dips associated with the interconnection/disconnection operation of cogeneration system are analyzed, including restraint solutions at the customer level. In addition, the unit capacity of cogeneration systems per feeder are evaluated from the view point of momentary voltage variations. The results of this paper are useful analysis data for interconnection standards/guidelines of cogeneration systems and dispersed generation (DG)

  • PDF