• 제목/요약/키워드: Park Kil Yong

검색결과 394건 처리시간 0.034초

이중 노드 복구가 가능한 분산 저장 시스템의 MTTDL (MTTDL for Distributed Storage Systems with Dual Node Repair Capability)

  • 길용성;김상효;박호성
    • 한국통신학회논문지
    • /
    • 제42권2호
    • /
    • pp.345-348
    • /
    • 2017
  • 본 논문은 분산 저장 시스템의 내구도 평가 지표인 기대 데이터 수명(Mean Time To Data Loss; MTTDL)을 이중 노드 복구가 가능한 상황에서 분석하고 단일 노드 복구 상황과 비교하였다.

UPFC를 이용한 선로 과부하 해소에 관한 연구 (A Study on the Line Overload Alleviation Using Unified Power Flow Controller)

  • 강인수;이인용;박규홍;정재길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1023-1025
    • /
    • 1999
  • This paper provides the steady-state UPFC model referred as UPFC injection model for power flow control. The application of UPFC for the line overload alleviation is demonstrated through a numerical example. It is shown that UPFC has the capability of regulating the power flow, therefore alleviating the line overload.

  • PDF

전계 효과 트랜지스터로 제어하는 전계 방출 소자의 시뮬레이션에 의한 특성 평가 (Characteristics of MOSFET-Structured Silicon Field Emitter by Computer Simulation)

  • 김진호;길태현;윤상한;김용상;박진석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1318-1320
    • /
    • 1998
  • We have investigated the electrical characteristics of a MOSFET-structured silicon field emitter by employing Maxwell 2D and Silvaco simulators. The potential distribution is obtained by Maxwell 2D simulator and the field emission current is calculated by Fowler-Nordheim equations. The characteristics of MOSFET is simulated by Silvaco simulator. Simulated results are almost identical to the experimental results. Also, we have studied the emission characteristics as funtions of several geometric parameters.

  • PDF

자외선 반응기의 구성에 따른 해수처리 (Seawater Treatment depending on Configuration of UV Chambers)

  • 최용기;박대원;김일권;이정윤;길경석;천상규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 전기공동학술대회 논문집
    • /
    • pp.190-190
    • /
    • 2011
  • 본 논문에서는 자외선 처리방식의 선박평형수 처리시스템의 최적 설계를 위하여 동일 소비전력에서 살균 챔버의 구성에 따른 해수처리성능에 대하여 기술하였다. 20 W 저압 자외선 램프 9개를 설치한 살균챔버와 10 W 저압 자외선 램프를 18개 사용한 2단 구성의 살균챔버를 사용하여, 15 $m^3$/h로 해수를 처리하고 처리 전후의 해수내 미생물에 대한 처리성능을 비교.분석하였다.

  • PDF

$TiO_2$ 광촉매의 해수살균 (Disinfection of Seawater by a $TiO_2$ Photocatalyst)

  • 박대원;김일권;차상욱;최용기;길경석;천상규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 전기공동학술대회 논문집
    • /
    • pp.189-189
    • /
    • 2011
  • 본 논문에서는 에너지 절감형 선박평형수 처리시스템 개발을 위하여, 저압 자외선 램프의 살균효율의 증대를 위한 광촉매 처리방법에 대하여 기술하였다. $TiO_2$ 광촉매를 석영관 주위에 감싸는 방법으로 살균챔버 내부에 설치하고 253.7 nm파장의 자외선과 광촉매에 의한 해수내 미생물 살균효과를 분석하였다.

  • PDF

Sterols of sewage indicators in marine sediments of Jinhae Bay, Korea

  • Choi, Hee-Gu;Kim, Sang-Gyoon;Kim, Sang-Soo;Moon, Hyo-Bang;Lee, Pil-Yong;Park, Chung-Kil
    • Journal of the korean society of oceanography
    • /
    • 제37권2호
    • /
    • pp.51-57
    • /
    • 2002
  • The ${\Delta}^5$ sterols were measured in be sediments of Jinhae Bay surrounded by industrial cities to assess the sewage-derived contamination. The total concentrations of total sterols ranged from 2.03 to 19.56 ${\mu}g/g$ dry wt. The principal sterol was cholesterol with a contribution of more than 50% to total sterols. Coprostanol, providing an indication of long-term sewage loads, was found in all sediment samples and the concentrations were 0.03-3.86 ${\mu}g/g$ dry wt, accounting for 1-26% to total sterols. The cluster analysis of sampling stations indicated that the sewage-derived contamination was localized in inner Masan Bay.

고압 CV 케이블에서의 부분방전 측정과 위치검출 방법에 관한 연구 (A Study on the measurement and Method of Partial Discharge in High Voltage CV Cable)

  • 송재용;서황동;박대원;길경석;한문섭;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.867-872
    • /
    • 2005
  • This paper describes the measurement and location method of partial discharges in high voltage CV cables. Coupling capacitors were used to detect partial discharge signal. Impedance characteristic of the coupling circuit and an amplifier with a high Common Mode Rejection Ratio(CMRR) were studied to improve sensitivity of the circuit. From the calibration experiment, the sensitivity of the partial discharge detection circuit was about 100pC. Also, we confirmed that the location of partial discharges in cables can be estimated by calculation of time difference between the first pulse and the second one reflected from the other end of the cable.

Transforming Growth Factor-${\alpha}$ Increases the Yield of Functional Dopaminergic Neurons from in vitro Differentiated Human Embryonic Stem Cells Induced by Basic Fibroblast Growth Factor

  • Lee, Keum-Sil;Shin, Hyun-Ah;Cho, Hwang-Yoon;Kim, Eun-Young;Lee, Young-Jae;Wang, Kyu-Chang;Kim, Yong-Sik;Lee, Hoon-Taek;Chung, Kil-Saeng;Park, Se-Pill;Lim, Jin-Ho
    • 한국수정란이식학회:학술대회논문집
    • /
    • 한국수정란이식학회 2003년도 제3회 발생공학 국제심포지움 및 학술대회
    • /
    • pp.102-102
    • /
    • 2003
  • PDF

전원회로용 서지방호장치의 설계 및 제작 (Design and Fabrication of a Surge Protective Device for Electrical Mains on Shipboard)

  • 문승보;박대원;송재용;길경석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1035-1040
    • /
    • 2005
  • This paper deals with the design rule and performance results of the surge protective devices (SPDs) for low-voltage mains on shipboard. The proposed SPDs consists of a metal oxide varistors (MOV) and a L-C filter to improve noise-elimination performance. Three kinds of SPDs are fabricated and tested by using a combination surge generator which produce the standard impulse current of 8/20${\mu}s$ 2.1kA. As a results, the proposed SPDs with series L-C filter have more excellent transient blocking and noise reduction performance than the conventional ones.

  • PDF