• Title/Summary/Keyword: Parameter Pattern Analysis

Search Result 271, Processing Time 0.029 seconds

Analysis of Luminance Degradation characteristics of OLED using the Hotplate (핫플레이트를 이용한 OLED의 휘도열화특성 분석)

  • Kim, Yun-Cheol;Lee, Duek-Jung;Jang, Joong-Soon
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.356-363
    • /
    • 2016
  • Purpose: The purpose of this study is to propose efficiency of equipment testing the luminance degradation of OLED. Methods: The degradation model of Exponential model and Stretched exponential model is analyzed by goodness of fit test using calculated R-square. The degradation model having the higher R-square is finally selected. Scale parameter and Shape parameter using the selected degradation model is estimated. The activation energy and current density n using peck model among the accelerated model is estimated. the estimated parameters are analyzed by t-test. Results: The results of t-test show that the estimated parameters on chamber and hotplate are equal statistically. we can know the similarity of the luminance degradation rate and degradation pattern on chamber and hotplate. Conclusion: The result of the degradation test on chamber and hotplate is similar. when the accelerated degradation test on the panel of the OLED TV is performed, hotplate is requiring less samples, time and cost than chamber. so the accelerated degradation test on the panel of the OLED TV using the hoplate is efficient of time and cost.

The effect of taping therapy on hemiplegic gait (테이핑 요법이 편마비 환자의 보행에 미치는 영향)

  • Lee, Ilsuk;Lim, Hyungmoon;Choi, Sanho;Oh, Jaegun;Lee, Sangkwan;Sung, Kang-keyng
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.49-60
    • /
    • 2013
  • ■ Objectives The aim of this study is to analyze the change of gait pattern by the taping therapy in a hemiplegic patient. ■ Methods We conducted the taping therapy for 7 days to affected ankle joint of hemiplegic patient and analyzed the change of gait pattern using Treadmill Gait analysis equipment(Zebris Co.Ltd FDM-T) ■ Results In terms of affected side, cadence, total double support, step length and stance phase decreased, while swing phase and step time increased by taping therapy. In terms of unaffected side, step length increased by taping therapy. Center of pressure intersection point moved to posterior and affected side in cyclogram pattern. ■ Conclusion Taping therapy to affected ankle joint of hemiplegic patient would be advantages to gait improvement in hemiplegic patients.

  • PDF

Analysis of Domestic Water Consumption Characteristics for Water Usage Purpose (가정용수의 사용 목적별 소비경향 특성분석)

  • Choi, Sun-hee;Son, Mi-na;Kim, Sang-hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.23-29
    • /
    • 2008
  • Throughout the analysis of field data from water distribution system, valid parameters were determined that can be included in the water service and design plan. This study investigates water consumption patterns to understand the variation of water-demand structures utilizing the pattern analysis of domestic purpose water. Water use data were collected by a public water resources management firm in Korea, Kwater, for 140 houses monitored during three years. Flow meters were installed at the faucet for drinking water, the shower booth, the laundry machine, bathroom sink, toilet, and garden faucet. Data was filtered using multiple physically meaningful criteria to improve analysis credibility. Mann Kendall and Spearman's Rho tests were used to carry out the analysis. Distinct factors of water consumption patterns can be determined for both increasing and decreasing trends of water use. Throughout the data analysis, the characterization of terms was classified and analyzed by the condition of the location of water-demand. Analysis of this data provide a physical basis for the parameter configuration of a reasonable design for a domestic water demand prediction model.

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

A Study on the Effective Symbolic Expression Methods of Uniform Design (유형별 유니폼 디자인의 효과적인 상징표현 방법)

  • Kim, Yun-Hee;Lee, Jae-Jung
    • Journal of the Korean Society of Costume
    • /
    • v.56 no.8 s.108
    • /
    • pp.148-159
    • /
    • 2006
  • The objective of this study is to consider the uniform as visual communication, and analyze the expression of symbol shown on the uniform design by the pattern by applying the visual symbol in the communication and operation of the meaning. Also, it is to construct the systematic modeling method of the expression of design symbol by the pattern of uniform in th e various fields. This study is to analyze the symbolic expression method of the uniform design by the pattern by suggesting the symbolic expression method as a frame through the visual symbolic approach of the uniform design and the analysis of semantic symbol according to that. As a result, there arose simplification and emphasis and a method of symbolic expression with the national flag, a conceptual factor characteristically in the sports uniform design. The characteristics of symbolic expression of uniform design were mainly used in the symbolic expression with the customary code and symbol. Also, the uniform in the enterprises were widely used in the expression of uniform with the suggestion and code by the color. As for the characteristics of symbolic expression shown on the event uniform design, the method of symbolic expression by the pattern of uniform was grasped differently asa result of symbolic expression through the image. The method of symbolic expression suggested on this study could be used on a basis of uniform design in the future. Accordingly, this study has a meaning of suggesting the methodology of uniform design that would be a parameter.

Discrete-Time Analysis of Throughput and Response Time for LAP Derivative Protocols under Markovian Block-Error Pattern (마르코프 오류모델 하에서의 LAP 계열 프로토콜들의 전송성능과 반응시간에 대한 이산-시간 해석)

  • Cho, Young-Jong;Choi, Dug-Kyoo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.11
    • /
    • pp.2786-2800
    • /
    • 1997
  • In this paper, we investigate how well the channel memory (statistical dependence in the occurrence of transmission errors) can be used in the evaluation of widely used error control schemes. For this we assume a special case named as the simplest Markovian block-error pattern with two states, in which each block is classified into two classes of whether the block transmission is in error or not. We apply the derived pattern to the performance evaluation of the practical link-level procedures, LAPB/D/M with multi-reject options, and investigate both throughput and user-perceived response time behaviors on the discrete-time domain to determine how much the performance of error recovery action is improved under burst error condition. Through numerical examples, we show that the simplest Markovian block-error pattern tends to be superior in throughput and delay characteristics to the random error case. Also, instead of mean alone, we propose a new measure of the response time specified as mean plus two standard deviations 50 as to consider user-perceived worst cases, and show that it results in much greater sensitivity to parameter variations than does mean alone.

  • PDF

Realtime Wireless Monitoring of Abnormal ST in ECG Using PC Based System

  • Jeong, Gu-Young;Yu, Kee-Ho;Kim, Nam-Gyun;Inooka, Hikaru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.176-180
    • /
    • 2004
  • The ST-segment that the beginning part of T wave is the important diagnostic parameter to finding myocardial ischemia. Abnormal ST appears in two types. One is the level change, and the other is the pattern change. In this paper, we describe the monitoring of abnormal ST using PC based system. Hardware of this system consists of transmitter, receiver and PC. The function of transmitter is measuring ECG in three channels which are selected manually and transmitting the data to receiver by digital radio way. Connection with receiver and PC is by RS232C, and the data received on the PC is analyzed automatically by ECG analysis algorithm and saved to file. In the algorithm part for detecting abnormal ST, ST-segments are approximated by a polynomial. This method can detect all of the deviation and pattern change of ST-segment regardless the change in the heart rate or sampling rate. To gain algorithm reliability, the method rejects distorted polynomial approximation by calculation the difference between the approximated ST-segment and original ST-segment. In pre-signal processing, the wavelet transformation separates high frequency bands including QRS complex from the original ECG. Consequently, the process improves the performance of detecting each feature points.

  • PDF

End-to-end Transmission Performance of VoIP Traffics based on Mobility Pattern over MANET with IDS (IDS가 있는 MANET에서 이동패턴에 기반한 VoIP 트래픽의 종단간 전송성능)

  • Kim, Young-Dong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.7
    • /
    • pp.773-778
    • /
    • 2014
  • IDS(Intrusion Detection System) can be used as a countermeasure for blackhole attacks which cause degrade of transmission performance by causing of malicious intrusion to routing function of networks. In this paper, effects of IDS for transmission performance based on mobility patterns is analyzed for MANET(Mobile Ad-hoc Networks), a suggestion for effective countermeasure is considered. Computer simulation based on NS-2 is used in performance analysis, VoIP(Voice over Internet Protocol) as an application service is chosen for performance measure. MOS(Mean Opinion Score), call connection ratio and end-to-end delay is used as performance parameter.

HSA-based HMM Optimization Method for Analyzing EEG Pattern of Motor Imagery (운동심상 EEG 패턴분석을 위한 HSA 기반의 HMM 최적화 방법)

  • Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.8
    • /
    • pp.747-752
    • /
    • 2011
  • HMMs (Hidden Markov Models) are widely used for biological signal, such as EEG (electroencephalogram) sequence, analysis because of their ability to incorporate sequential information in their structure. A recent trends of research are going after the biological interpretable HMMs, and we need to control the complexity of the HMM so that it has good generalization performance. So, an automatic means of optimizing the structure of HMMs would be highly desirable. In this paper, we described a procedure of classification of motor imagery EEG signals using HMM. The motor imagery related EEG signals recorded from subjects performing left, right hand and foots motor imagery. And the proposed a method that was focus on the validation of the HSA (Harmony Search Algorithm) based optimization for HMM. Harmony search algorithm is sufficiently adaptable to allow incorporation of other techniques. A HMM training strategy using HSA is proposed, and it is tested on finding optimized structure for the pattern recognition of EEG sequence. The proposed HSA-HMM can performs global searching without initial parameter setting, local optima, and solution divergence.

A Comparative Study on Software Reliability Model for NHPP Intensity Function Following a Decreasing Pattern (강도함수가 감소패턴을 따르는 NHPP 소프트웨어 신뢰모형에 관한 비교 연구)

  • Kim, Hee Cheul;Kim, Jong Buam;Moon, Song Chul
    • Journal of Information Technology Applications and Management
    • /
    • v.23 no.4
    • /
    • pp.117-125
    • /
    • 2016
  • Software reliability in the software development process is an important issue. In infinite failure non-homogeneous Poisson process software reliability models, the failure occurrence rates per fault. can be presented constant, monotonic increasing or monotonic decreasing pattern. In this paper, the reliability software cost model considering decreasing intensity function was studied in the software product testing process. The decreasing intensity function that can be widely used in the field of reliability using power law process, log-linear processes and Musal-Okumoto process were studied and the parameter estimation method was used for maximum likelihood estimation. In this paper, from the software model analysis, we was compared by applying a software failure interval failure data considering the decreasing intensity function The decreasing intensity function model is also efficient in terms of reliability in the arena of the conservative model can be used as an alternating model can be established. From this paper, the software developers have to consider life distribution by preceding information of the software to classify failure modes which can be gifted to support.