• Title/Summary/Keyword: Paralleling

Search Result 98, Processing Time 0.026 seconds

New Switching Pattern for the Paralleling of SRM Low Voltage Inverter (저전압형 SRM 인버터의 병렬운전 위한 새로운 스위칭)

  • 이상훈;박성준;원태현;안진우;이만형
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.6
    • /
    • pp.359-367
    • /
    • 2004
  • The switched reluctance motor(SRM) has considerable potential for industrial applications because of its high result lily as a result of the absence of rotor windings. In some applications with SRM, paralleling strategy is often used for cost saving, increasing of current capacity and system reliability. A SRM inverter has very low ,switching frequency. This results in reducing the burden for a high-speed of the gate-amp interface circuit. and the linearity of optocoupler is used to protect the instantaneous peak current for the stable operation. In this paper, series resistor is used to equal the current sharing of each switching device and a linear gate-amp is proposed to protect the instantaneous peak current which occurs in transient state. The proposed paralleling strategy is verified by experimental results.

SKIN ABSORBED DOSES FROM FULL MOUTH STANDARD INTRAORAL RADIOGRAPHY IN BISECTING ANGLE AND PARALLELING TECHNIQUES (각이등분법 및 평행법에 의한 전악 구내 표준 촬영시 두경부 피부 흡수선량 비교)

  • Kim Ae-Ji;Nah Kyung-Soo;Doh Shi-Hong;Kim Hyun-Ja;Yoo Meong-Jin
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.315-333
    • /
    • 1990
  • This study was performed to measure the skin absorbed doses from full mouth standard intraoral radiography (l4 exposures) in bisecting angle and paralleling techniques. Thermoluminescent dosimeters were used in a phantom. Circular tube collimator(60㎜ in diameter, 20㎝ in length) and rectangular collimator(35㎜ × 44㎜, 40㎝ in length) were set for bisecting angle and paralleling techniques respectively. All measurement sites were classified into 8 groups according to distance from each point of central rays. The results were as follows: 1. The skin absorbed doses from the paralleling technique were significantly decreased than those from the bisecting technique in both points at central ray and points away from central ray. The percentage rates of decrease were greater at points away from central ray than those at central ray. 2. The skin absorbed doses at the lens of eye, parotid gland, submandibular gland and thyroid region were significantly decreased in paralleling techniuqe, but those of the midline of palate remained similar in both techniques. 3. The highest doses were measured at the site 20mm above the point of central ray for the mandibular premolars in bisecting angle technique and at the point of central ray for the mandibular premolars in paralleling techniques. The lowest doses were measured at the thyroid region in both techniques.

  • PDF

A Comparative Study on Rate of Error with Bisecting Angle Technique and Paralleling Technique (등각촬영법과 평행촬영법에서의 실책 비교 연구)

  • Lee, Kyeong-Hee;Park, Il-Soon;Jung, Jung-Ock
    • Journal of dental hygiene science
    • /
    • v.11 no.3
    • /
    • pp.155-161
    • /
    • 2011
  • The purpose of this study was to obtain data necessary for guiding students in the future by grasping which rate of error is made how much depending on a shooting technique in the filming of periapical radiograph. 14,402 films, which were instructed targeting students for the Department of Dental Hygiene at D Health College and S Health College, were analyzed. The following results were obtained by conducting questionnaire survey targeting 263 students who completed the shooting practice lesson of bisecting angle technique and paralleling technique. 1. In case of having shot with bisecting angle technique, the ratio of error was the highest in both maxillary and mandibular first molar. 2. In case of having shot with paralleling technique, the ratio of error was the highest in the maxillary bicuspid and the mandibular first molar. 3. As for ratio of error in light of a shooting technique, both bisecting angle technique and paralleling technique were indicated to be the highest in inaccuracy of film position. The bisecting angle technique was indicated to have the higher ratio of error compared to the paralleling technique. 4. As for ratio of error in light of the processing technique, both bisecting angle technique and paralleling technique were indicated to be the highest in dark image and light image. The bisecting angle technique was indicated to have the higher ratio of error compared to the paralleling technique. 5. Students were indicated to feel it to be most difficult for grasping the processing level in the film-developing process. As the above results, to reduce ratio of error given the periapical radiography, a method of reducing ratio of error given the periapical radiography is considered to be what correctly understands the morphological and anatomical structure inside the mouth and what acquires the shooting technique by filming several times with having enough time.

The Accuracy of the Radiographic Method in Root Canal Length Measurement (근광장 측정에서 방사선 사진술의 정확도)

  • Jo Eun-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

A Novel Paralleling Method of Converters for Reduction of Hippie in Output Voltage (컨버터의 출력전압 리플 저감을 위한 새로운 병렬운전 방법에 대한 연구)

  • Park, Sung-Woo;Park, Hee-Sung;Jang, Jin-Beak;Jang, Sung-Soo;Kim, Jong-Duck
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.237-240
    • /
    • 2004
  • For the paralleled operation of DC/DC converters, the current sharing between each modules is the most important for the reliability of the power system. Interleaving method is commonly used with many paralleling schemes for the reduction of the ripple in the output voltage of paralleled converters and there are many commercial IC for interleaving application appliable. But for all of them, it is impossible to detect the number of module in operating and then change the phase of them automatically. In this paper, a novel paralleling method is proposed for the converter parallel operation, which detects the number of modules in active and sets the phases of PWM signals applied to each modules autonomously. This can greatly improve the output voltage ripple and reliability of the system. The expandibility of modular number can be done very easily by just adding several parts.

  • PDF

Switch Paralleling Characteristic Analysis for FB Converter in 1[kW] Fuel-Cell System (풀브리지 컨버터를 갖는 1[kW] 연료전지 시스템 스위치 병렬 특성 분석)

  • Choi, Jung-Muk;Han, Dong-Hwa;Lee, Young-Jin;Jeong, Byong-Hwan;Choe, Gyu-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.62-70
    • /
    • 2010
  • Fuel cell system which can solve the environmental problem is receiving attention. To use utility power necessary power conversion system from low voltage that is generated by fuel cell system. because fuel cell has special characteristic of low voltage high current. To improve PCS's efficiency the paralleling method is used. Available the method could reduce the switching loss. But the existing research could not be found optimal result and accompanying several effects. In this study analysis several effects causing the parallel method. The effects have been demonstrated through simulations and experiments.

Dynamic Paralleling Behaviors of High Power Trench and Fieldstop IGBTs

  • Wu, Yu;Sun, Yaojie;Lin, Yandan
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.788-795
    • /
    • 2014
  • This paper demonstrates the dynamic behaviors of paralleled high power IGBTs using trench and fieldstop technologies. Four IGBTs are paralleled and standard deviation is adopted to represent the imbalance. Experiments are conducted under three different operation conditions and at different temperatures ranging from $-25^{\circ}C$ to $125^{\circ}C$. The experimental results show that operation at very low and very high temperatures usually aggravates the switching behaviors. There is a trade-off between the balance and the losses at low temperatures. These results can help in the design of heat sinks in paralleling applications confronting very low temperatures.

Comparison of the Rate of Error with the Bisecting Angle Technique and the Paralleling Technique (등각촬영법과 평행촬영법에 따른 실책율 비교)

  • Lee, Yeong-Ae;Jo, Min-jung
    • Journal of dental hygiene science
    • /
    • v.4 no.3
    • /
    • pp.97-102
    • /
    • 2004
  • In order to find out the rate of error according to intraoral standard radiographic techniques, this study analyzed 3,251 standard films, and conducted a questionnaire with 120 Daegu Health College students who have used the bisecting angle technique and the paralleling technique. Followed are the results of the study: 1. The rate of error was the highest in canine from both maxilla and mandible when used by the bisecting angle technique. 2. The rate of error was the highest in premolar from both maxilla and mandible when used by the paralleling technique. 3. The technical error was occurred most frequently in elongation. 4. The rate of error and distortion was higher in the bisecting angle technique than in the paralleling technique. 5. The processing error was occurred most frequently in light film. 6. In applying radiographic techniques, the subjects indicated that the vertical angulation of central radiation in the bisecting angle technique and the oral fixation of film holder in the paralleling technique were the most difficult.

  • PDF

A Study about Output Filter of Paralleled Three-Phase Grid-Connected PV Inverters

  • Vu, Trung-Kien
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.271-272
    • /
    • 2011
  • The rising popularity of renewable energy sources resulted in development of the units of higher rated powers. As a result of the limited power handling capacity of individual devices, paralleling is the choice to increase the equipment rating, while keeping the THD of the current at the PCC within the agency specified standards. And their typical power circuit configuration limits the stress on individual devices to an appreciable extent. The main scope of this paper is the analysis of filter structure in paralleling inverter system's operation. Simulation results are shown to verify the theoretical analysis.

  • PDF

A survey study on recognition of periapical radiography in dental hygiene students (치위생과 학생의 치근단 촬영법 인식에 관한 조사 연구)

  • Park, Il-Soon;Jung, Jung-Ock;Lee, Kyeong-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.5
    • /
    • pp.987-997
    • /
    • 2012
  • Objectives : This study was carried out in order to obtain basic data for students' efficient acquirement and instruction of radiography technology in the future by surveying dental hygiene students' recognition of periapical radiography. Methods : This study carried out a questionnaire survey targeting dental hygiene students from December 2009 to December 2010, and obtained the following results. Results : 1. As a result of examining recognition on periapical radiography, the bisecting angle technique was indicated to be averagely $3.84{\pm}0.566$ points. The paralleling technique was indicated to be $2.66{\pm}0.701$ points. 2. As a result of examining about problems given the bisecting angle technique, what had been most difficult given the bisecting angle technique was indicated to be the highest in cone positioning with 34.2%. The most difficulty given deciding on the X-ray vertical-angel irradiation direction was indicated to be the highest with 66.9% in adjusting the cone direction on the virtual bisector. 3. As a result of examining about problems given the paralleling technique, what had been most difficult in the process of the paralleling technique was indicated to be the highest with 56.7% in fixing the film immobilization device inside the mouth. Conclusions : Examining the above results, it is considered that there is a need of understanding morphological and anatomical structure inside the mouth in order to reduce the mistake rate given the periapical radiography, and that it is important to increase skill level by repetitively shooting several times with having enough time.