The purpose of this study was to obtain data necessary for guiding students in the future by grasping which rate of error is made how much depending on a shooting technique in the filming of periapical radiograph. 14,402 films, which were instructed targeting students for the Department of Dental Hygiene at D Health College and S Health College, were analyzed. The following results were obtained by conducting questionnaire survey targeting 263 students who completed the shooting practice lesson of bisecting angle technique and paralleling technique. 1. In case of having shot with bisecting angle technique, the ratio of error was the highest in both maxillary and mandibular first molar. 2. In case of having shot with paralleling technique, the ratio of error was the highest in the maxillary bicuspid and the mandibular first molar. 3. As for ratio of error in light of a shooting technique, both bisecting angle technique and paralleling technique were indicated to be the highest in inaccuracy of film position. The bisecting angle technique was indicated to have the higher ratio of error compared to the paralleling technique. 4. As for ratio of error in light of the processing technique, both bisecting angle technique and paralleling technique were indicated to be the highest in dark image and light image. The bisecting angle technique was indicated to have the higher ratio of error compared to the paralleling technique. 5. Students were indicated to feel it to be most difficult for grasping the processing level in the film-developing process. As the above results, to reduce ratio of error given the periapical radiography, a method of reducing ratio of error given the periapical radiography is considered to be what correctly understands the morphological and anatomical structure inside the mouth and what acquires the shooting technique by filming several times with having enough time.
Keywords
Bisecting angle technique; Paralleling technique; Ratio of error;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 강은주, 이경희, 주온주: 치과 방사선 촬영실의 촬영실태와 방사선 안전관리 실태에 관한 조사 연구. 치위생과학회지 5(2): 83-88, 2005.
2 박창서 등: 구강영상학. 제 1판. 고문사, 서울, pp. 165, 2009.
3 이영애, 조민정: 등각촬영법과 평행촬영법에 따른 실책율 비교. 치위생과학회지 4(3): 97-192, 2004
4 이혜진, 이정화: 등각촬영법 실책율 비교에 대한 조사. 치위생과학회지 12(2): 25-31, 2006.
5 이삼선: 치과에서의 방사선안전관리. 치학연구소 37(1): 117-126, 2007.
6 Crandell CE: Cause and frequency of intraoral X-ray errors by dental hygiene student. J Dent Edue 22(1): 189-196, 1971.
7 장계원: 일부 치과위생학생들의 치과방사선 실습에 관한 분석. 진주보건대학논문집 25(2): 1-9, 2004.
8 International Commossion on Radiological Protection 1990 Recommendation of the international commission on Radiological Protection. Ann ICRP 21: 1-201, 1991.
9 Mettler FA Jr, Wiest PW, Locken JA, Kelsey CA. CT scanning: Patterns of use and dose. J Radiol Prot 10: 353-359, 2000.
10 최갑식, 변종수, 최순철: 구내전악표준방사선사진 촬영시 촬영법과 필름유지법에 따른 촬영상의 실책. 대한구강악안면방사선학회지 16(1): 103-112, 1986.
11 Pharoah MJ: Imaaging techniques and their clinical significance. Int J Prosth 6(1): 176-179, 1993.
12 이미희: 치근단 필름 촬영법의 실책율 비교. 제주관광대학 논문집 11(1): 35-41, 2005.
13 박일순 등: 구강방사선학 실습. 제 3판. 고문사, 서울, pp.30, 2007.