• 제목/요약/키워드: Parallel connection

검색결과 358건 처리시간 0.023초

모멘트쌍 액추에이터가 적용된 PPF에 의한 평판의 능동진동제어 (Positive Position Feedback Control of Plate Vibrations Using Moment Pair Actuators)

  • 신창주;홍진숙;정의봉;유호영
    • 한국소음진동공학회논문집
    • /
    • 제22권4호
    • /
    • pp.383-392
    • /
    • 2012
  • This paper reports the active vibration control of plates using a positive position feedback(PPF) controller with moment pair actuators. The equations of motion of the plates under a force and moment pairs are derived and the equations of PPF controllers are formulated. The numerical active control system is then achieved. The effect of the parameters - gain and damping ratio - of the PPF controllers on the open loop transfer function was investigated mainly in terms of the system stability. Increasing the gain of the PPF controller tuned at a mode, the magnitude of the open loop transfer function is increased at all frequencies without changing the phase behavior. The increase of the damping ratio of the PPF controller leads to decrease the magnitude of the open loop transfer function and to modify its phase characteristics, ie, system stability. Based on the behavior of the gain and the damping ratio of the controller, PPF controller for reduction of the plate vibration can be achieved. Two PPF controllers are designed with their connection in parallel to control the two modes simultaneously. Each PPF controller is tuned at the $1^{st}$ and $2^{nd}$ modes, respectively. Their parameters were determined to remain the system to be stable based on the results of the parametric study. A significant reduction in vibration at the tuned modes can be obtained.

Numerical Analysis of Si-based Photovoltaic Modules with Different Interconnection Methods

  • Park, Chihong;Yoon, Nari;Min, Yong-Ki;Ko, Jae-Woo;Lim, Jong-Rok;Jang, Dong-Sik;Ahn, Jae-Hyun;Ahn, Hyungkeun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권2호
    • /
    • pp.103-111
    • /
    • 2014
  • This paper investigates the output powers of PV modules by predicting three unknown parameters: reverse saturation current, and series and shunt resistances. A theoretical model using the non-uniform physical parameters of solar cells, including the temperature coefficients, voltage, current, series and shunt resistances, is proposed to obtain the I-V characteristics of PV modules. The solar irradiation effect is included in the model to improve the accuracy of the output power. Analytical and Newton methods are implemented in MATLAB to calculate a module output. Experimental data of the non-uniform solar cells for both serial and parallel connections are used to extend the implementation of the model based on the I-V equation of the equivalent circuit of the cells and to extend the application of the model to m by n modules configuration. Moreover, the theoretical model incorporates, for the first time, the variations of series and shunt resistances, reverse saturation current and irradiation for easy implementation in real power generation. Finally, this model can be useful in predicting the degradation of a PV system because of evaluating the variations of series and shunt resistances, which are critical in the reliability analysis of PV power generation.

Bus-voltage Sag Suppressing and Fault Current Limiting Characteristics of the SFCL Due to its Application Location in a Power Distribution System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1305-1309
    • /
    • 2013
  • The application of the superconducting fault current limiter (SFCL) in a power distribution system is expected to contribute the voltage-sag suppression of the bus line as well as the fault-current reduction of the fault line. However, the application effects of the SFCL on the voltage sag of the bus line including the fault current are dependent on its application location in a power distribution system. In this paper, we investigated the fault current limiting and the voltage sag suppressing characteristics of the SFCL due to its application location such as the outgoing point of the feeder, the bus line, the neutral line and the 2nd side of the main transformer in a power distribution system, and analyzed the trace variations of the bus-voltage and fault-feeder current. The simulated power distribution system, which was composed of the universal power source, two transformers with the parallel connection and the impedance load banks connected with the 2nd side of the transformer through the power transmission lines, was constructed and the short-circuit tests for the constructed system were carried out. Through the analysis on the short-circuit tests for the simulated power distribution system with the SFCLs applied into its representative locations, the effects from the SFCL's application on the power distribution system were discussed from the viewpoints of both the suppression of the bus-voltage sag and the reduction of the fault current.

Design and Evaluation of a Protection Relay for a Wind Generator Based on the Positive- and Negative-Sequence Fault Components

  • Zheng, Taiying;Cha, Seung-Tae;Kim, Yeon-Hee;Crossley, Peter A.;Lee, Sang Ho;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1029-1039
    • /
    • 2013
  • To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a delay for inter-tie or grid faults, and it can avoid operating for parallel WG or adjacent feeder faults. A WG protection relay based on the positive- and negative-sequence fault components is proposed in the paper. At stage 1, the proposed relay uses the magnitude of the positive-sequence component in the fault current to distinguish faults requiring non-operation response from those requiring instantaneous or delayed operation responses. At stage 2, the fault type is first determined using the relationships between the positive- and negative-sequence fault components. Then, the relay differentiates between instantaneous operation and delayed operation based on the magnitude of the positive-sequence fault component. Various fault scenarios involving changes in position and type of fault and faulted phases are used to verify the performance of the relay. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. Results indicate that the relay can successfully distinguish the need for instantaneous, delayed, or non-operation.

페라이트계 스테인리스강(STS430) 이면전단 볼트접합부의 구조거동에 관한 실험적 연구 (An Experimental Study on Structural Behaviors of Double Shear Bolted Connections Fabricated with Ferritic Stainless Steel (STS430))

  • 김태수;김민성
    • 한국강구조학회 논문집
    • /
    • 제25권5호
    • /
    • pp.463-474
    • /
    • 2013
  • 일면전단 오스테나이트계 스테인리스강 및 탄소강에 관한 많은 실험 및 해석적 연구가 수행되어졌고, 수정된 내력평가식이 제안되었다. 본 연구에서는 볼트배열(2행 1열, 2행 2열)과 하중방향 연단거리를 주요변수로 하여 이면전단 볼트접합부 실험체가 제작되었고, 단순인장실험이 실시되었다. 고정변수로는 하중직각방향 연단거리, 볼트직경, 피치, 게이지를 설정하였다. 최대내력과 파단형태와 같은 실험결과와 현행기준식에 의한 예측결과와 비교 검토되었다. 볼트배열에 따른 블록전단내력평가식이 제안되었다.

Current Limiting Characteristics of a Flux-Lock Type SFCL for a Single-Line-to-Ground Fault

  • Oh, Geum-Kon;Jun, Hyung-Seok;Lee, Na-Young;Choi, Hyo-Sang;Nam, Gueng-Hyun
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.70-77
    • /
    • 2006
  • We have fabricated an integrated three-phase flux-lock type SFCL, which consists of an YBCO($YB_a2Cu_3O_7$) thin film and a flux-lock reactor wound around an iron core of each phase. In order to apply the SFCL in a real power system, fault analyses for the three-phase system are essential. The short-circuit currents were effectively limited by adjusting the numbers of winding of each secondary coil and their winding directions. The flux flow generated in the iron core cancelled out under the normal operation due to the parallel connection between primary and secondary windings. However, the flux-lock type SFCL with same iron core was operated just after the fault due to the flux generating in the iron core. To analyze the current limiting characteristics, the additive polarity winding was compared with the subtractive one in the flux lock reactor. Whenever a single line-to-ground fault occurred in any phase, the peak value of the line current of the fault phase in the additive polarity winding increased up to about 12.87 times during the first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to about 34.07 times under the same conditions. This is because the current flow between the primary and the secondary windings changed to additive or subtractive status according to the winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to-ground fault

성과관리의 수용성 제고 방안 : 공기업사례를 중심으로 (A Study on the Method for Promoting Acceptance on Performance Management : Focusing on the Public Enterprises Practices)

  • 김연성;유홍성;김순철
    • 한국경영과학회지
    • /
    • 제40권1호
    • /
    • pp.185-198
    • /
    • 2015
  • This study drew performance management factors analyzed a causal link between acceptance and satisfaction of performance management to present the method for promoting acceptance on the performance management system that most of the public enterprises, government-affiliated organizations are implementing. To achieve this, qualitative analysis and quantitative analysis were conducted in parallel through in-depth case studies and surveys. The results of this study are as follows. First, the analysis of the performance management factors with preceding studies shows that performance management indicators, performance management operations and performance management communications. Second, from the causal relationship of performance management factors affecting performance management acceptance reveals that performance management operation has statistical significance. Third, the analysis of the effect of performance management factors on the management satisfaction shows that operation and indicator of the performance management have statistical significance and reflecting the performance indicators to business, adequacy of target level, training, system support and CEO's Leadership have been revealed as important variables to the management satisfaction. Fourth, the result of the analysis on casual connection between acceptance and satisfaction of the performance management shows that improving management acceptance has a direct impact on satisfaction because performance management receptiveness were deemed statistically significant. Fifth, the result of the in-depth case studies on improving performance management acceptance shows that public enterprises have been putting in an effort to design indicators and try to encourage internal member's involvement during the monitoring and evaluation. The quantitative analysis based on survey has turned out that performance management operation and performance management indicators have statistical significance. The qualitative analysis by in-depth analysis shows that public enterprises put a lot of effort to performance management indicators and communication between internal members. As a result, commitment to performance management operation is required to improve the performance management acceptance. In other words, a detailed implementation plan for training, information system support, and CEO's leadership has to be established and ought to be pushed.

하수처리장 주요 기자재의 고장확률밀도함수를 이용한 가용도 모델링 및 평가에 관한 연구 (A Study on the Availability Modelling and Assessment with Failure Density Function of Major Equipment for a Sewage Treatment Plant)

  • 이홍철;곽필재;이현동;황인주
    • 대한환경공학회지
    • /
    • 제35권11호
    • /
    • pp.763-768
    • /
    • 2013
  • 본 논문에서는 하수처리장 주요 장비 고장밀도함수를 기반으로 시스템 가용성 평가가 수행되었다. 프로세스 구성과 구성요소의 고장률에 따른 시스템 가용성 및 위험요소 분석에 초점을 맞추고 있다. 하수처리장 시스템 가용성 분석을 위하여 기자재 분류와 해당기자재의 고장확률밀도함수를 정립하였다. 가용성 평가 과정의 불확실성의 해소를 위하여 몬테카를로 시뮬레이션 기법과 이벤트기법을 도입하였다. 하수처리장 시스템 가용성은 구성장비가 직렬연결 상태인 경우에 50.4%로 평가되었으며, 장비별 보조시스템이 추가 적용된 경우 80.1% 이상으로 증가하였다. 슬러지 탈수 및 농축 공정의 시스템 오작동은 전체 시스템 오작동의 77% 이상에 해당하고 있어 주 위험 요인으로 평가되었다.

손실이 있는 Left-Handed 전송선로를 이용한 감쇠기와 벡터 변조기 응용 (Attenuator using Lossy Left-Handed Transmission Line and Vector Modulator Application)

  • 김승환;김일규;김영;윤영철
    • 한국항행학회논문지
    • /
    • 제13권3호
    • /
    • pp.399-405
    • /
    • 2009
  • 본 논문은 메타 재질 구조를 바탕으로 한 가변 감쇠기와 그 응용에 대하여 기술 하였다. 손실이 존재하는 전송선로를 이용한 감쇠기 단위 셀은 CRLH(Composite Right/Left Handed) 전송선로와 다이오드 바이어스 전압에 따라서 내부 저항값의 변화에 따라서 손실을 제어할 수 있는 PIN다이오드로 구성되어 있다. 또한, 내부의 초기 삽입 손실을 줄이기 위해서 두 개의 PIN 다이오드를 병렬로 연결하였다. 이 감쇠기는 감쇠기 단위 셀 숫자를 증가시킴으로서 감쇠량을 증가시킬 수 있는 주기적 구조로 설계되었다. 단위 셀의 전기적 특성은 주파수 1.5 GHz ~ 2.5 GHz에서 10dB의 감쇠량과 최대 15o의 위상변화를 확인하였다. 이러한 특성의 감쇠기를 직렬로 연결하여 벡터 변조기에 응용하였다.

  • PDF

초광대역 대역통과여파기의 설계와 제작에 관한 연구 (A Study on the Design and Fabrication of the UWB Bandpass Filter)

  • 국정형;최병하;김규철;박정률;함민수
    • 한국항행학회논문지
    • /
    • 제13권1호
    • /
    • pp.41-47
    • /
    • 2009
  • 이 논문에서는 마이크로스트립을 이용하여 차단주파수가 10.2 GHz인 계단형 임피던스 구조의 저역 통과 여파기를 설계하고, 차단주파수 3.2 GHz인 병렬 스터브를 이용한 고역 통과 여파기를 설계하여 서로 결합하고 삽입하여 소형화하는 방식으로 UWB 대역을 포함하는 대역통과여파기를 설계, 제작하였다. 설계에 사용된 기판의 유전율은 2.2, 높이 0.508mm, loss tangent 0.0009이고, 대역통과 여파기의 넓이는 약 3 cm의 소형으로 제작되었다. 통과 대역에서의 측정 결과 -10 dB 대역폭은 7.5 GHz, -3dB 이하의 삽입손실의 특성을 보였다. 이 연구의 결과 UWB 통신 시스템과 MIC/MMIC, RFIC 시스템에 충분히 이용될 수 있을 것이다.

  • PDF