• 제목/요약/키워드: Parallel Flow Type

검색결과 146건 처리시간 0.026초

냉매 충전량에 따른 CO2용 수냉식 열펌프의 성능 특성에 관한 연구 (Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Variation of Refrigerant Charge Amount)

  • 손창효;유태근;장승일;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.558-566
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of refrigerant charge amount was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2400 mm length. The experimental results summarize as the followings : As the refrigerant charge ratio of $CO_2$ heat pump system increases, the discharge pressure and compressor ratio increases, but mass flow rate of refrigerant decreases. Also the compressor work increases with the increase of refrigerant charge ratio. However, the heating and cooling capacity of $CO_2$ heat pump decreases as the refrigerant charge ratio increases. The maximum heating COP of $CO_2$ heat pump system presented at 0.25 refrigerant charge ratio. It is possible to confirm the optimum charge ratio of $CO_2$ heat pump system by the viewpoint of heating COP.

태양열 보조열원을 이용한 흡수식 시스템의 동적 시뮬레이션에 의한 과도운전 특성 평가 (Dynamic Simulation of Transient Operations of a Solar Power-Assisted Absorption Chiller)

  • 신영기;서정아;우성민
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.78-85
    • /
    • 2010
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism were modeled. And solar radiation and the solar collector were also modeled along with its control design. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the issues of the excessive circulation flow rate and the mismatch between available solar power and cooling load discourages the use of the single mode, but the dual use of gas and solar power is recommendable in view of controllability and enhanced COP.

모델휴먼프로세서를 활용한 인지과정 시뮬레이터 구축에 관한 연구 (A Study on Development of a Cognitive Process Simulator Based on Model Human Processor)

  • 이동하;나윤균
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.230-239
    • /
    • 1998
  • Though limited, Model Human Processor (MHP) has been used to explain the complex users' behaviors during human-computer interactions in a simplified manner. MHP consists of perceptual, cognitive and motor systems, each with processors and memories interacting with each other in serial or parallel mode. The important parameters of memory include the storage capacity, the decay time, and the code type of a memorized item. The important parameter of a processor is the cycle time. Using these features of the model, this study developed a computerized cognitive process simulator to predict the cognitive process time of a class match task process. An experimental validity test result showed that the mean prediction time for cognitive process of the class match task simulated 50 times by the simulator was consistent with the mean cognitive process time of the same task performed by 37 subjects. Animation of the data flow during the class match task simulation will help understand the invisible human cognitive process.

  • PDF

종속 접속된 전압제한형 서지방호장치의 에너지협조 (Energy Coordination of Cascaded Voltage Limiting Type Surge Protective Devices)

  • 이복희;신희경
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.29-35
    • /
    • 2013
  • For the purpose of designing and applying optimum surge protection, one of the essential points is to take into account the energy coordination between cascaded surge protective devices(SPDs) and it is important to obtain an acceptable sharing of the energy stress between two cascaded SPDs. In this paper, in case of two voltage-limiting SPDs connected in parallel, the amount of splitting impulse current and energy that flow through each SPDs is investigated as a function of the protective distance. As a result, the energetic coordination between cascaded SPDs is strongly dependent on the voltage protection level of SPDs and the protective distance. It was confirmed that the sharing of the energy between two cascaded SPDs and the limited voltage levels are appropriate when the voltage protection levels of both upstream and downstream SPDs are the same.

입자층(粒子層)을 이용한 열교환기(熱交換器)에서 소요동력(所要動力)에 따른 전열특성(傳熱特性)에 관(關)한 연구(硏究) (The Heat Transfer Performance with Pumping Power for a Particle Bed Heat Exchanger)

  • 유지오;양한주;조용철;서정윤
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.351-359
    • /
    • 1992
  • In order to improve the performance of heat exchanger, fluidized bed is often employed. The experiments are carried out in fluidized double pipe parallel flow heat exchanger in which finned tube is vertically immersed. And the heat transfer coefficients between the heated tube and fluidized bed of alumina beads(dp=0.41, 0.54, 0.65, 0.77mm) are calculated as a function of air fluidized velocity and pumping power. The effects of particle size, static bed height and pumping power on the heat transfer coefficients are investigated. And the heat transfer coefficients are compared with that of single phase forced convection heat exchanger. In particular, the heat transfer performance of each type heat exchanger is evaluated in relation to the pumping power.

  • PDF

직류 열 플라즈마의 발생및 그 특성에 관한 연구 (A Study On D.C. Thermal Plasma Generation And Its Characteristics)

  • 김원규;연충규;김준식;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.451-454
    • /
    • 1989
  • A DC thermal plasma generation system for both LPPS and APPS was designed and its characteristics was analysed. Discharge experiments for 60 conical and cylindrical type anode nozzle were conducted and the results were compaerd each other. The flow dependence and the electrode gap dependence were precisely explained and especially voltage jump phenomena under the existance of the parallel magnetic field was studid.

  • PDF

PVA 배열층을 이용한 펜타신 유기 박막 트랜지스터의 전기적 특성 (An Electrical Characteristics on the Pentacene-Based Organic Thin-Film Transistors using PVA Alignment Layer)

  • 전현성;오환술
    • 한국전기전자재료학회논문지
    • /
    • 제23권3호
    • /
    • pp.177-182
    • /
    • 2010
  • The pentacene-based organic thin film transistors(OTFTs) using polyvinylalcohol(PVA) alignment layer were fabricated on the $SiO_2$ evaporated to n-type (111) Si substrates. The pentacene film was deposited by thermally evaporated at $10^{-7}$ torr. X-ray diffraction (XRD) and atomic force microscope(AFM) measurement showed pentacene film which deposited on rubbed PVA layers were partially crystallized at (001) plane. The pentacene OTFTs with PVA layers rubbed perpendicular to the direction of current flow was shown to align better orientation than parallel rubbed case and thus to enhance the mobility and saturation current by a factor of 2.3 respectively. We obtained mobility by 0.026 $cm^2$/Vs and on-off current ratio by ${\sim}10^8$.

고주파 임피던스를 이용한 토양수분함량 측정에 관한 연구 (Measurement of Soil Moisture Content Using RF Impedance in the Range of 1 to 30MHz)

  • 김기복;이남호;노상하
    • 한국농공학회지
    • /
    • 제40권6호
    • /
    • pp.79-88
    • /
    • 1998
  • This study was conducted to measure the moisture content of soil using RF impedance in the range of 1 to 30MHz. Considering the water potential flow in the soils, two types of sensor such as parallel cylinder and perpendicular plate type were fabricated and tested. The capacitance and resistance of sonsors for soil samples having moisture content range of 2 to 27% were measured by Q-meter (HP4342). The higher soil moisture content was and the larger soil bulk density was, the more the capacitance of sensors increased. To eliminate the effect of bulk density on measuring soil moisture content using RF impedance, two kinds of model having the density independent functions such as the ratio of capacitance change to conductance change and weight of water and dry soils respectively were developed and estimated by regression analysis.

  • PDF

거친사각채널에서 왕복운동이 열전달에 미치는 효과 (The Effect of Reciprocating Motion on Heat Transfer in the Roughened Rectangular Channel)

  • 안수환;손강필
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권6호
    • /
    • pp.646-652
    • /
    • 2002
  • The influence of reciprocating frequency and radius on heat transfer in the roughened rectangular channel is experimentally investigated. The aspect ratio (width/height) of the duct is 2.33 and the rib height is one fifteenth of the duct height. And the ratio of rib-to-rib distance to rib height is 10. The discrete ribs were periodically attached to the button wall of the duct with a parallel orientation. The parametric test matrix involves Reynolds number, reciprocating, and reciprocating radius, in the ranges, 1,000∼6,000, 1.7∼2.5 HB and 7∼15cm, respectively. The combined effects of reciprocating frequency and reciprocating radius have considerable influence on the heat transfer due to the modified vortex flow structure.

비용절감형 컨버터 구조를 갖는 3상-3상 PWM 정류기/인버터 시스템 (Novel Converter Topology for a Three Phase to Three Phase PWM Rectifier/Inverter System)

  • 김기택;박태열;이해춘
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.323-328
    • /
    • 1998
  • A current controlled VSI-PWM rectifier and inverter with capacitor dc link is regarded as one of the most promising structures for three-phase to three-phase to three-phase power conversion. This type of converter normally requires twelve switches for a rectifier and inverter composed of self turn-off switch such as a bi-polar transistor or IGBT with an anti-parallel diode. In this paper, a new three-phase to three-phase converter for ac motor drives is proposed. The proposed converter employs only eight switches and has the capability of delivering sinusoidal input currents with unity power factor and bidirectional power flow. This paper describes the feasibility and the operational limitations of the proposed structure. A mathematical model of the system is derived using generalized modulation theory and experimental results for steady state and dynamic behavior are presented to verify the developed model.

  • PDF