• 제목/요약/키워드: Parallel Flow

검색결과 1,068건 처리시간 0.029초

병렬 유한요소 해석기법을 이용한 유동장 해석 (Parallel Finite Element Simulation of the Incompressible Navier-stokes Equations)

  • 최형권;김범준;강성우;유정열
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 춘계 학술대회논문집
    • /
    • pp.8-15
    • /
    • 2002
  • For the large scale computation of turbulent flows around an arbitrarily shaped body, a parallel LES (large eddy simulation) code has been recently developed in which domain decomposition method is adopted. METIS and MPI (message Passing interface) libraries are used for domain partitioning and data communication between processors, respectively. For unsteady computation of the incompressible Wavier-Stokes equation, 4-step splitting finite element algorithm [1] is adopted and Smagorinsky or dynamic LES model can be chosen fur the modeling of small eddies in turbulent flows. For the validation and performance-estimation of the parallel code, a three-dimensional laminar flow generated by natural convection inside a cube has been solved. Then, we have solved the turbulent flow around MIRA (Motor Industry Research Association) model at $Re = 2.6\times10^6$, which is based on the model height and inlet free stream velocity, using 32 processors on IBM SMP cluster and compared with the existing experiment.

  • PDF

Hall Effect on Couette Flow with Heat Transfer of a Dusty Conducting Fluid Between Parallel Porous Plates Under Exponential Decaying Pressure Gradient

  • Attia Hazem A.
    • Journal of Mechanical Science and Technology
    • /
    • 제20권4호
    • /
    • pp.569-579
    • /
    • 2006
  • In the present study, the unsteady Couette flow with heat transfer of a dusty viscous incompressible electrically conducting fluid under the influence of an exponential decaying pressure gradient is studied without neglecting the Hall effect. The parallel plates are assumed to be porous and subjected to a uniform suction from above and injection from below while the fluid is acted upon by an external uniform magnetic field is applied perpendicular to the plates. The governing equations are solved numerically using finite differences to yield the velocity and temperature distributions for both the fluid and dust particles.

축소 유로내의 두 평행 유동에 대한 해석 (Analysis on Two Parallel Flows in Convergent Channel)

  • 권진경;김태욱;김진현;김재열
    • 한국추진공학회지
    • /
    • 제10권4호
    • /
    • pp.11-18
    • /
    • 2006
  • 축소 유로에서의 두 평행 유동의 합류에 의한 복합유동과 그 초킹 현상이 일차원 등엔트로피 모델과 완전혼합 모델에 의해 계산되었다. 아음속-아음속의 복합유동에 대해 압력측정과 광학 측정이 실시되었으며 그 결과를 일차원 계산의 결과와 비교하였다. 결과적으로 복합유동의 한쪽 유동의 입구조건은 다른 유동의 거동과 초킹 조건에 영향을 미침을 알 수 있었으며 본 실험의 결과는 일차원 계산 결과와 비교적 잘 일치함을 알았다.

공조장치내의 직렬-직렬 대향류 냉각기에서 최적 변수 (The optimal parameters in series-series counterflow chillers system within air conditioning)

  • 웬민푸;뷔옥훙;이근식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1332-1336
    • /
    • 2009
  • If water-chillers are arranged in series-series counterflow, compressor lift of each chiller will be decreased in comparison with water-chillers in parallel. That means that compressor power of the chillers in series will be lower than that of chillers in parallel. However, the pressure drop of the water flow through the chillers in series will increase, and thus increase the power of water pumps. This disadvantage will be made good by increasing the temperature difference of water flow through evaporator and condenser, but the water flow rates will decrease. This paper explores the optimal parameters in system of series-series counterflow for central chilled water plants such as the leaving chilled water temperature, the leaving condenser water temperature, condenser water flow rate and number of chillers in series.

  • PDF

균일한 전단응력에 의한 혈관내피세포의 운동성 변화 (EFFECTS OF UNIFORM SHEAR STRESS ON THE MIGRATION OF VASCULAR ENDOTHELIAL CELL)

  • 신현정;송석현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1404-1408
    • /
    • 2008
  • The migration and proliferation of vascular endothelial cells (VEC), which play an important role in vascular remodeling, are known to be regulated by hemodynamic forces in the blood vessels. When shear stresses of 2, 6, 15 dynes/$cm^2$ are applied on mouse micro-VEC in vitro, cells surprisingly migrate against the flow direction at all conditions. While higher flow rate imposes more resistance against the cells, reducing their migration speed, the horizontal component of the velocity parallel to the flow increases with the flow rate, indicating the higher alignment of cells in the direction parallel to the flow at a higher shear stress. In addition, cells exhibit substrate stiffness and calcium dependent migration behavior, which can be explained by polarized remodeling in the mechanosensitive pathway under shear stress.

  • PDF

병렬화 컴파일러의 구조 (Organization of Parallelizing Compilers)

  • 이재경;지동해;창병모
    • 전자통신동향분석
    • /
    • 제9권4호
    • /
    • pp.9-21
    • /
    • 1994
  • Wide variety of the architectural complexity of parallel computer often makes it difficult to develop efficient programs for them. One of approaches to improve this difficulty is to program in familiar sequential languages such as Fortran or C and to parallelize sequential programs into equivalent parallel programs automatically. This paper presents an organization of parallelizing compiler which transforms sequential programs into equivalent parallel programs. The parallelizer consists mainly of syntax analysis, control and data flow analysis, program transformation, and parallel code generation. In particular, the program restructuring in this parallelizer maximizes loop parallelism.

평행선 지지식 추력베어링에 관한 연구 (A Study on the Parallel Line Pivoted Pad Thrust Bearing)

  • 이경우;김종수;제양규
    • Tribology and Lubricants
    • /
    • 제15권1호
    • /
    • pp.24-28
    • /
    • 1999
  • This paper describes a new pivoting technique to improve bearing performance in pivoted pad thrust bearings. This new technique adjusts the pivot line in a line pivoted pad thrust bearing to be parallel to the trailing edge of a sector shaped pad. Bearing performance factors such as load carrying capacity, frictional torque and flow rate are numerically investigated for conventional point-pivoted and line-pivoted pads and for the new parallel-line pivoting technique. It is shown that the load carving capacity can be maximized with the new technique.

INFLUENCE OF SLIP CONDITION ON RADIATIVE MHD FLOW OF A VISCOUS FLUID IN A PARALLEL POROUS PLATE CHANNEL IN PRESENCE OF HEAT ABSORPTION AND CHEMICAL REACTION.

  • VENKATESWARLU, M.;VENKATA LAKSHMI, D.;DARMAIAH, G.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제20권4호
    • /
    • pp.333-354
    • /
    • 2016
  • The present investigation deals, heat and mass transfer characteristics with the effect of slip on the hydromagnetic pulsatile flow through a parallel plate channel filled with saturated porous medium. Based on the pulsatile flow nature, exact solution of the governing equations for the fluid velocity, temperature and concentration are obtained by using two term perturbation technique subject to physically appropriate boundary conditions. The expressions of skin friction, Nusselt number and Sherwood number are also derived. The numerical values of the fluid velocity, temperature and concentration are displayed graphically whereas those of shear stress, rate of heat transfer and rate of mass transfer at the plate are presented in tabular form for various values of pertinent flow parameters. By increasing the slip parameter at the cold wall the velocity increases whereas the effect is totally reversed in the case of shear stress at the cold wall.

Numerical Analysis of the Effect of a Three-Dimensional Baffle Structure with Variable Cross-Section on the Parallel Flow Field Performance of PEMFC

  • Xuejian Pei;Fayi Yan;Jian Yao;He Lu
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권4호
    • /
    • pp.333-348
    • /
    • 2023
  • In this study, a 3D model of the proton exchange membrane fuel cell is established, and a new 3D baffle structure is designed, which is combined with the parallel flow field and then optimized by numerical simulation methods. The number of baffles and the cross-sectional trapezoidal base angle are taken as the main variables, and their impacts on the performance indexes of the cathode side are analyzed. The results show that the 3D baffle can facilitate the convection and diffusion mass transfer of reactants, improve the uniformity of oxygen distribution, enhance the drainage capacity, and make the cell performance superior; however, too small angle will lead to excessive local convective mass flux, resulting in the decrease of the overall uniformity of oxygen distribution and lowering the cell performance. Among them, the optimal number of baffles and angle are 9 and 58°, respectively, which improves the net output power density by 10.8% than conventional flow field.

알루미늄 평행류 열교환기에서 냉매패스와 분배량 변화의 영향 (The Effect of refrigerant pass & distribution in aluminum parallel flow heat exchanger)

  • 김정식;김내현;김광희
    • 한국산학기술학회논문지
    • /
    • 제10권12호
    • /
    • pp.3546-3552
    • /
    • 2009
  • 본 연구에서는 천정 설치형 공조기 적용을 위해 연구가 활발히 진행되고 있는 알루미늄 평행류 증발기 해석 프로그램을 개발하여 190mm*650mm*25mm(W*H*D) 크기의 열교환기를 해석하였다. R410A냉매의 분배비가 일정하고 상하로 유동하는 2, 3 패스의 경우와 3 패스이고 분배비율(1:1:1, 1:2:2)을 달리할 때, 열교환 성능을 예측하였다. 계산 결과, 2 패스가 3 패스보다 국소 전열량이 30% 정도 높았지만, 건도에 따른 열전달계수는 25% 낮았으며, 3 패스의 경우, 분배비 1:1:1 보다 1:2:2가 냉매 압력손실이 높게 나타났다. 본 해석에서는 패스당 냉매가 균일하게 분포하는 것으로 가정하였으므로, 패스별로 불균일하게 유동되는 실제의 경우보다 열교환성능을 과대 예측하는 것으로 판단된다.