• Title/Summary/Keyword: Paper materials

Search Result 12,292, Processing Time 0.053 seconds

지르코니아 표면 처리와 시멘트 종류에 따른 치면과의 전단 결합 강도 비교 연구 (In Vitro Evaluation of Shear Bond Strengths of Zirconia Cerami with Various Types of Cement after Thermocycling on Bovine Dentin Surface)

  • 조수현;조인호;이종혁;남기영;김종배;황상희
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.249-257
    • /
    • 2007
  • State of problem : The use of zirconium oxide all-ceramic material provides several advantages, including a high flexural strength(>1000MPa) and desirable optical properties, such as shading adaptation to the basic shades and a reduction in the layer thickness. Along with the strength of the materials, the cementation technique is also important to the clinical success of a restoration. Nevertheless, little information is available on the effect of different surface treatments on the bonding of zirconium high-crystalline ceramics and resin luting agents. Purpose : The aim of this study was to test the effects of surface treatments of zirconium on shear bond strengths between bovine teeth and a zirconia ceramic and evaluate differences among cements Material and methods : 54 sound bovine teeth extracted within a 1 months, were used. They were frozen in distilled water. These were rinsed by tap water to confirm that no granulation tissues have left. These were kept refrigerated at $4^{\circ}C$ until tested. Each tooth was placed horizontally at a plastic cylinder (diameter 20mm), and embedded in epoxy resin. Teeth were sectioned with diamond burs to expose dentin and grinded with #600 silicon carbide paper. To make sure there was no enamel left, each was observed under an optical microscope. 54 prefabricated zirconium oxide ceramic copings(Lava, 3M ESPE, USA) were assigned into 3 groups ; control, airborne-abraded with $110{\mu}m$ $Al_2O_3$ and scratched with diamond burs at 4 directions. They were cemented with a seating force of 10 ㎏ per tooth, using resin luting cement(Panavia $F^{(R)}$), resin cement(Superbond $C&B^{(R)}$), and resin modified GI cement(Rely X $Luting^{(R)}$). Those were thermocycled at $5^{\circ}C$ and $55^{\circ}C$ for 5000 cycles with a 30 second dwell time, and then shear bond strength was determined in a universal test machine(Model 4200, Instron Co., Canton, USA). The crosshead speed was 1 mm/min. The result was analyzed with one-way analysis of variance(ANOVA) and the Tukey test at a significance level of P<0.05. Results : Superbond $C&B^{(R)}$ at scratching with diamond burs showed the highest shear bond strength than others (p<.05). For Panavia $F^{(R)}$, groups of scratching and sandblasting showed significantly higher shear bond strength than control group(p<.05). For Rely X $Luting^{(R)}$, only between scratching & control group, significantly different shear bond strength was observed(p<.05). Conclusion : Within the limitation of this study, Superbond $C&B^{(R)}$ showed clinically acceptable shear bond between bovine teeth & zirconia ceramics regardless of surface treatments. For the surface treatment, scratching increased shear bond strength. Increase of shear bond strength by sandblasting with $110{\mu}m$ $Al_2O_3$ was not statistically different.

콘크리트의 탄산화 관점에서 CO2 배출량-흡수량 평가에 관한 연구 (Study on the Evaluation CO2 Emission-Absorption of Concrete in the View of Carbonation)

  • 이상현;이성복;이한승
    • 콘크리트학회논문집
    • /
    • 제21권1호
    • /
    • pp.85-92
    • /
    • 2009
  • 콘크리트는 생산과정에서 다량의 이산화탄소를 배출하는 시멘트를 사용하기 때문에 반친환경적 재료로 인식되고 있다. 하지만 콘크리트는 사용기간 중 탄산화 과정을 통하여 대기중의 이산화탄소를 흡수한다. 이에 본 연구에서는 기존문헌 고찰을 통하여 1) 콘크리트 내 탄산화 가능한 물질의 농도, 2) 탄산화된 콘크리트의 체적, 3) 이산화탄소 분자량을 이용, 탄산화를 통한 콘크리트의 이산화탄소 흡수량의 정량적 산출 방법을 제시하였다. 또한 콘크리트 생산에 사용되는 재료들의 이산화탄소 배출량 자료를 이용하여 단위 콘크리트 생산에 따른 이산화탄소 배출량을 정량적으로 산출하였다. 이러한 콘크리트의 이산화탄소 흡수량 및 배출량의 정량적 산출방법을 이용하여 실제 사용중인 아파트 건축물 1동을 대상으로 하여 콘크리트의 생산에 따른 배출량과 사용기간에 따른 이산화탄소 흡수량을 정량적으로 산출하여 이산화탄소의 배출량-흡수량 평가를 실시하였다. 그 결과 건축물을 40, 60, 80년 사용시, 사용된 콘크리트의 이산화탄소 배출량 대 흡수량의 비율이 3.65, 4.47, 5.18%로 나타났다. 본 연구는 콘크리트 생산 및 사용에 따른 이산화탄소 배출량-흡수량의 정량적 산정방법에 연구의 목적을 두었으며 이산화탄소 배출량-흡수량 평가 결과 구조물을 80년 사용할 시 약 5.18%로 그 값이 미비하였으나 시멘트의 혼화재 치환율 증가를 통한 배출량 저감과 탄산화 체적 증가를 통한 이산화탄소 흡수량 증가를 통해 배출량-흡수량을 향상시킬 수 있으며, 향후 콘크리트의 이산화탄소 배출량-흡수량 평가에 본 연구의 방법이 유용하게 활용될 수 있을 것으로 판단된다.

18~19世紀 茁浦灣의 煮鹽 - 鹽場의 分布와 煮鹽法을 중심으로 - (A study on the traditional salt-making of the Joolpo inlet area during the 18th and 19th century)

  • 홍금수
    • 대한지리학회지
    • /
    • 제29권1호
    • /
    • pp.46-64
    • /
    • 1994
  • 본 논문은 18세기에서 19세기에 이르는 전환기적 시기에 줄포만에서 행해진 자염을 소재로하여 당 지역의 역사지리적 경관복원을 시도해 본 것이다. 먼저 자염업의 성립배경과 관련해서 줄포만은 넓은 간석지를 근간으로 한 지형적 측면을 포함해 조석, 기후, 식생, 토 양 등 자연지리적 제 조건의 혜택하에 염업이 활성화 될 수 있었다. 사회경제적으로는 인구 증가, 농민층의 분해, 교환경제및 어업의 발달 등이 자염발달의 촉발요인이 되었다. 당시의 염장은 고부, 부안, 홍덕, 무장 등 4개 군현에 걸쳐 분포하였으며, 이 가운데 고부의 것은 월 경지인 부안면에 소재한 것으로 밝혀졌다. 그리고 본지역 자염의 기원지는 무장의 검당으로 비정하였다. 주요 제염설비에는 염막, 염전, 섯등, 염정, 염조, 염부 등이 있었고 실 작업에는 제염도구로 재래농기구가 동원되었다. 제염은 물때에 맞추어 행해지며 섯등굴착. 염토살포, 염밭갈이, 섯등구축, 염수회득, 자염의 과정을 거쳐 화염을 얻어내는 형태를 취하였다.

  • PDF

Ti-6Al-4V 합금 표면에 생성된 $TiO_2$ 나노튜브의 전석회화 처리 (Precalcification Treatment of $TiO_2$ Nanotube on Ti-6Al-4V Alloy)

  • 김시정;박지만;배태성;박은진
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.39-45
    • /
    • 2009
  • 연구목적: 최근 치과용 임플란트의 임상 경향이 전체 치료기간을 줄일 수 있는 방법에 관심이 집중됨에 따라 불활성의 티타늄 임플란트 표면에 활성을 부여하기 위한 다양한 표면처리 방법이 검토되고 있다. 본 연구에서는 높은 강도가 요구되는 부위의 임플란트 재료로서 사용되고 있지만 표면 특성이 순 티타늄에 비해 떨어지는 Ti-6Al-4V 합금의 골전도성을 개선할 목적으로 시행되었다. 연구 재료 및 방법: $20{\times}10{\times}2\;mm$의 Ti-6Al-4V 합금판을 준비한 다음 $TiO_2$ 나노튜브를 형성하기 위해 DC 정전원 장치의 양극과 음극에 각각 시편과 백금판을 결선하고 0.5 M $Na_2SO_4$와 1.0 wt% NaF를 함유하는 전해액을 사용하여 전압 20 V와 전류밀도 $30\;㎃/cm^2$ 조건에서 2시간 동안 양극산화 처리하였다. $TiO_2$ 나노튜브 형성 후 산화 피막층의 결정화를 유도하기 위해 $600^{\circ}C$에서 2시간 동안 열처리하였고, 표면활성도를 개선하기 위해 0.5 M $Na_2HPO_4$ 수용액 24시간 침적과 $Ca(OH)_2$ 포화 수용액에 5시간 침적을 시행하였다. 준비한 시편의 표면 반응성을 조사하기 위해 pH와 무기이온의 농도를 사람의 혈장과 유사하게 조절한 Hanks 용액 (H2387, Sigma Chemical Co., USA)에 2주간 침적하였다. 결과: 20 V에서의 양극산화처리로 직경 48.0 - 65.0 ㎚ 범위의 무정형의 $TiO_2$ 나노튜브가 전체 표면에 걸쳐서 균일하게 생성되는 양상을 보였다. $TiO_2$ 나노튜브는 $600^{\circ}C$에서 2시간 열처리 후 상대적으로 강한 anatase 피크와 함께 rutile 피크가 관찰되었다. $TiO_2$ 나노튜브의 표면활성도는 0.5 M $Na_2HPO_4$ 수용액 24시간 침적과 $Ca(OH)_2$ 포화수용액에 5시간 침적으로 개선되었다. 열처리와 전석회화 처리 후 SBF에 침적한 결과, $TiO_2$ rutile 피크의 상대적 강도는 크게 증가되었지만 HA의 석출은 저하되는 경향을 보였다. 결론: 이상의 결과로 미루어 볼 때, 양극산화 처리한 $TiO_2$ 나노튜브는 $600^{\circ}C$에서의 열처리에 의해 피막층이 안정화되고, 0.5 M $Na_2HPO_4$ 수용액 24시간 침적과 $Ca(OH)_2$ 포화수용액에 5시간 침적으로 표면에 인산칼슘층을 형성하는 것이 표면활성도를 개선하는데 유효함을 알 수 있었다.

만성 폐질환 환자에서 재택 호흡재활치료방법 개발 연구 (Development of the Home-Based Pulmonary Rehabilitation Program for Patients with Chronic Lung Disease)

  • 윤성호;나주옥;제갈양진;김명화;김응석;심태선;임채만;이상도;고윤석;김우성;김원동;김동순
    • Tuberculosis and Respiratory Diseases
    • /
    • 제52권6호
    • /
    • pp.597-607
    • /
    • 2002
  • Background : Even though it is well known that pulmonary rehabilitation (PR) improves exercise capacity, and the quality of life, in patients with chronic lung diseases, not many patients can attend hospital based intensive PR in Korea. The purpose of this study was to develop a method for a home-based PR program, and study its effectiveness. Materials and Methods : Twenty patients with chronic lung diseases were randomly divided into two groups : a home PR group comprising of 10 male patients, with a mean age of 70 years, and a control group comprising of 10 male patients, with a mean age of 65 years. We developed exercise programs, depending on the exercise capacity of each patient, which were easy to do at home. The PR program consisted of a 12 week period of enforced aerobic (mostly walking) and muscle strengthening exercises, as prescribed by the exercise specialist, in accordance with the functional capacity of the patient. In addition to the education, nutritional and psychiatric consultation was undertaken, and respiratory muscle training arranged. Patients visited hospital every 2 weeks for evaluation and exercise prescription. Results : All patients finished the 12 week course of therapy. Following the home PR, the endurance times and work capacity of the upper and lower extremities were significantly increased in the treatment group in comparison to the controls. The six minute working (Eds note:should) 'working' read "walking"?) distance was increased from $465{\pm}60m$ to $508{\pm}37m$ and the maximal inspiratory pressure from $72.8{\pm}27.2cmH_2O$ to $91.4{\pm}30.9cmH_2O$. The quality of life, as assessed by St Georges Respiratory Questionnaire (SGRQ), was also improved following PR. (Eds note:do you have figures for before and after, and a reference for the SGRQ?i.e. for the main paper.) Conclusion : The home PR program we developed seemed to be applicable, and effective, to most of the patients with chronic lung diseases in this study.

의사의 전원의무(轉院義務) 위반 여부의 판단기준과 전원시점 판단 - 판례의 동향을 중심으로 - (A Study on the Decision Point and a Standard of Judgment under the Duty of Inter-hospital Transfer for Patients of Doctor - Focused on the Trend of Supreme Court's Decisions -)

  • 최현태
    • 의료법학
    • /
    • 제20권1호
    • /
    • pp.163-201
    • /
    • 2019
  • 의사에게는 환자와의 법률관계에서 비롯되는 여러 의무들이 존재한다. 그 중 하나가 의사 자신이 속해 있는 의료기관이 치료 및 진료를 위한 인프라나 의료기술이 부족한 것으로 판단하는 경우 환자를 적절한 진단 검사 및 진료가 가능한 의료기관으로 '전원(轉院)'하여야 하는 주의의무인 전원의무(轉院醫務)이다. 의료기관마다 환자의 응급성 정도에 따라 대응할 수 있는 능력이 다르므로 의사의 지시나 권고에 의하여든 환자 본인의 요청에 의하여든 이와 같은 환자의 전원은 불가피한 현상이다. 예를 들어 심각한 뇌손상을 입은 환자가 내원한 경우, 진단, 검사 장비 및 인력을 갖추지 못한 병원의 의사로서는 적절한 시기(이른바 '골든타임')에 진단, 검사 및 진료가 가능한 상급의료기관으로 전원을 고려하여야 한다. 이처럼 전원의무는 의사의 의무 중 하나인 것으로 의사뿐만 아니라 환자들에게도 널리 인식되고 있다. 그러므로 적절한 전원 시점을 놓치게 되어 의료사고가 발생한 상황에서는 전원의무위반 여부와 관련한 의사와 환자 간의 법적 분쟁이 있을 수밖에 없다. 본 연구에서는 이러한 상황과 관련하여 전원의무에 대한 구체적이고도 명확한 판단 기준 정립과 함께 현재 각 의료기관들에 마련되어 있는 가이드라인이 실제 적용에서의 여러 시행착오들을 반영하고 있는지에 대한 검토가 필요하다고 보고, 의사의 전원의무에 대한 판례의 동향 분석을 중심으로 전원의무 관련 판례에서 이미 제시되어 있는 판단 기준 요소들이 적절한지 그리고 현재 실무에서 적용되는 법령 및 가이드라인 등과 부합되는지 여부를 살펴봄으로써 앞으로 응급환자에 대한 의사의 전원의무 관련 분쟁조정 및 소송에서의 해석과 적용에 기여할 수 있도록 하였다.

표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향 (The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate)

  • 오주영;김정열;오기백;오신현;김재삼;이창호;박훈희
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.53-61
    • /
    • 2013
  • 방사성 요오드 갑상선 섭취율은 거대갑상선 환자의 경우 그 체적에 의한 유효 갑상선 깊이가 깊어짐으로 인한 기하학적 변동이 있는 것이 사실이다. 본 연구는 방사성 요오드갑상선 섭취율에 있어 검출기와 선원 간 거리와 유효 갑상선 깊이에 따른 기하학적 요인의 영향을 고찰하고자 하였다. $^{131}I$ 370 kBq 선원을 검출기로부터 거리를 20 cm부터 30cm까지 1 cm 간격으로 변화시키며 Captus 3000 thyroid uptake system(Capintec, NJ, USA)으로 측정하였다. 유효갑상선 깊이를 재현하기 위해 목 팬텀을 이용하여 팬텀 내 선원의 깊이를 1 cm, 2 cm, 5 cm으로 변화시키며 같은 방법으로 측정하였다. 실험 결과, 곡선추정 회귀분석 결과 모든 실험군이 거듭제곱곡선에 높은 상관관계를 보이는 것으로 나타났다($$R2{\geq_-}0.915$$). 그러므로 검출기-선원 간 거리가 20 cm보다 30 cm에서 오차가 크게 감소됨을 예상할 수 있다. 모든 실험군에서 팬텀을 쓰지 않았을 때와 유효 갑상선깊이가 1 cm이 적용되었을 때의 계수율이 서로 유의할 만한 차이가 있는 것으로 나타났다(p<0.01). 선형회귀분석 결과 깊이에 따른 계수율의 변화는 모두 감소되는 것으로 나타났으나,$284.3keV{\pm}10%$ 영역에서 깊이에 따른 계수율의 변화는 증가되는 것으로 나타났다. 이 회귀식을 통해 환자의 예상 갑상선 섭취율을 산출해 보았을 때, $364.4keV{\pm}10%$에서 1 cm 당 -6.42%, $364.4keV{\pm}20%$의 영역에 서 -5.09%의 더 낮은 오차를 보였다. 또한 거리에 따른 계수율의 변동계수는 모든 실험군에서 선형으로 증가되는 것으로 나타났다. 그 중 $364.4keV{\pm}20%$, $364.4keV{\pm}10%$ 영역은 비교적 낮은 변동계수와 증가폭을 보였다. 곧, 유효 갑상선 깊이에 따른 오차를 줄이기 위해서는 $364.4keV{\pm}20%$의 영역의 사용이 더 적절할 것으로 보인다. 그러므로 갑상선 깊이에 따른 오차는 갑상선 깊이에 따른 보정계수 적용,$364.4keV{\pm}20%$ 에너지 영역 설정, 디텍터와 선원과의 거리를 연장하였을 때 감소시킬 수 있다고 생각된다.

  • PDF

중소기업 특성에 따른 외부 협업 활동이 혁신성과에 미치는 영향 (Performance of Collaboration Activities upon SME's Idiosyncrasy)

  • 이혜선;오준석;이재기;이봉규
    • 인터넷정보학회논문지
    • /
    • 제14권6호
    • /
    • pp.95-105
    • /
    • 2013
  • 최근 급변하고 있는 시장변화로 기업의 경쟁우위를 지속하기 위한 기업 간 협업 활동과 그 중요성이 증가되고 있다. 특히 한정된 자원을 보유한 중소기업의 외부자원 활용과 협업 활동은 기업 내 역량강화 및 혁신성과 창출함 있어 중요한 요소로 자리 잡고 있다. 현재까지의 대다수 선행연구들에서는 중소기업의 다양한 특성과 협업의 연관성을 세부적으로 구분하여 혁신성과를 해석하기보다 기업의 크기(대기업과 중소기업)와 연구개발 활동 등의 환경적 요인으로 구분하여 협업과 성과의 영향정도를 규명하였다. 이에 본 연구에서는 국내 중소기업의 외부 협업 활동과 관련한 기업의 다양한 특성과 혁신성과 유형에 미치는 영향력 정도를 분석하고자 하였다. 이에 기업의 특성을 주 제품이 속한 산업군, 고객군, 기업 규모로 구분하였으며, 각 유형에 따른 협업 활동이 제품혁신과 공정혁신 성과에 미치는 영향력을 살펴보았다. 본 연구에서는 프로빗 모형을 사용하였으며, 분석결과 외부협업은 제품혁신에는 큰 영향을 미치지만 공정혁신에는 유의미한 영향을 미치지 않는 것으로 나타났다. 또한 중소기업의 주 제품군이 속한 산업과 고객에 따른 협업 활동의 경우, 전반적으로 두 유형의 혁신성과에 다양한 영향을 미치는 것으로 나타났다. 또한 기업 규모가 큰 경우, 외부와의 협업 활동이 규모가 작은 기업보다 혁신성과에 큰 영향을 미치는 것으로 나타났다. 본 연구결과를 바탕으로 지속적인 성과창출에 필요한 기업특성에 따른 협업의 영향력을 인지함으로써 향후 소규모 기업들을 위한 혁신성과 창출을 위한 전략을 도입하려는 실무자 및 기관 관계자들에게 도움이 될 것으로 기대된다.

PET/CT검사에서 Dose Modulation Technic 적용시 BMI에 따른 선량 감소율 분석 (Analysis of Dose Reduction Rate with Dose Modulation Technic Depending on BMI)

  • 김정욱;박세윤;조영준;박종엽
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.25-28
    • /
    • 2012
  • PET/CT에서의 환자의 피폭선량을 줄이기 위한 많은 연구가 진행되고 있다. 본 연구는 2012년 2월부터 2012년 3월까지 PET/CT검사를 위해 본원 핵의학과에 내원한 환자 149명(평균연령 $58{\pm}12.4$세)을 대상으로 하였고 장비는 Biograph True Point 40 (Siemens, USA)과 Gemini TF 64 (Philips, Cleveland)를 사용하였다. SIEMENS사의 Care Dose 4D를 사용하여 75명의 환자를 BMI 지수에 따라 세 집단으로 나누어 선량 감소율과 CTDI를 측정하였고 PHILIPS사의 D-dom을 이용하여 74명의 환자를 세 집단으로 나누어 선량 감소율과 CTDI를 측정하였다. 각 장비별로 세 집단 간의 측정값들이 유의한 차이를 보이는지 알아보기 위하여 SPSS Ver.18.0 통계분석프로그램을 이용하였다. 각각의 집단별로 평균값을 비교한 결과 Care Dose 4D를 사용했을 때 선량 감소율, CTDI 모두 p-value가 0.000으로서 통계적으로 유의한 차이가 있었다. D-dom을 사용했을 때 집단 간의 p-value는 선량 감소율 0.284, CTDI 0.226으로서 p>0.05이므로 집단 간의 유의한 차이가 없었다. 집단별로 평균 선량 감소율과 CTDI를 분석한 결과 Care Dose 4D를 사용했을 때 각각 정상집단에서 53.4%, 5.3 mGy, 과체중집단에서 49.5%, 5.8 mGy, 비만 집단에서 42.0%, 6.6 mGy로 나타났다. 반면에 D-dom을 사용하였을 때는 각각 정상 집단에서 22.7%, 4.5 mGy, 과체중 집단에서 22.1%, 4.6 mGy, 비만 집단에서 22.9%. 4.5 mGy로 나타났다. D-dom의 원리인 투사각도에 따른 선량조절은 환자의 비만도에 영향이 많지 않음을 알 수 있었다. 그리고 Care Dose 4D의 경우에는 투사각도에 따른 선량조절뿐만 아니라 환자 장축의 감쇠계수에 따른 선량조절, 환자 사이즈에 따른 선량조절 원리를 사용하고 있다. 그러므로 환자 장축의 감쇠계수에 따른 선량조절과 환자 크기에 따른 선량조절 원리가 환자의 비만도에 영향이 있다고 생각된다. 비록 같은 BMI 집단 간에 환자의 체형에 따른 오차가 있다고 여겨지지만, 앞으로 더욱더 많은 연구가 이루어진다면 Dose Modulation Technic이 PET/CT검사에서 환자의 피폭선량을 줄이는데 많은 도움이 될 것으로 생각된다.

  • PDF

방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가 (The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy)

  • 김영선;서명덕;이완규;김기준;송재범
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.12-17
    • /
    • 2012
  • 방사성 요오드 치료병실에서 나온 환의 및 시트는 본디 방사성폐기물로서 관련 규정에 따라 일반 쓰레기와 동일하게 처리해야 하지만 사정상 일정기간 보관하여 방사능을 감쇄시킨 후 재사용하게 된다. 통상 최소보관기간 산출에 표면오염도(Bq/$m^2$)를 기반으로 하는 반출기준을 적용하고 있다. 하지만 방사선측정기를 이용하여 단위 면적당 총방사능량을 구하는 방법은 측정방법에 따라 편차와 불확실성이 상당히 커진다. 본 연구에서는 '방사성폐기물 자체처분 등에 관한 규정'에서 제시하고 있는 핵종 농도(Bq/g)를 Dose Calibrator를 이용하여 직접 측정하여 최소보관기간을 구함으로써, 환의 및 시트의 정확한 재사용 주기를 산출하고자 한다. 한편 반출기준으로 산출한 최소보관기간과 비교하여 그 차이를 살펴보았다. 본원의 방사성 요오드 치료병실에서 2011년 7월부터 2012년 3월까지 I-131을 3.7 GBq (100 mCi) 이상을 사용하여 방사성 요오드 치료를 시행한 환자 31명이 사용한 환의와 시트의 방사선 오염도를 측정하여 최소보관기간을 산출하였다. 최소보관기간은 핵종 농도를 측정하여 '방사성폐기물 자체처분 등에 관한 규정'에 따라 100 Bq/g이 되는 시점과 표면오염도를 측정하여 반출기준에 따라 허용표면오염도의 1/10, 즉 4 kBq/$m^2$되는 시점을 붕괴식에 대입하여 산출하였다. 반출기준으로 산출한 최소보관기간은 침대/담요시트는 14.2일, 베개시트는 4.6일, 환의(상(上))은 63일, 환의(하(下))는 78일 이었으며, 자체처분 기준에 따른 최소보관기간은 베개시트는 18.1일, 환의(상(上))은 43일, 환의(하(下))는 62일로 산출되었다. 표면오염도와 핵종 농도의 상관관계를 분석해 본 결과 베개시트와 환의(상(上))는 상관관계가 높게 나타났으나, 환의(하)는 낮게 나타났다. 이는 베개시트와 환의는 방사성오염이 부분에 국한 되어 측정값이 일정한 반면, 환의(하(下))는 소변에 의한 방사성오염이 여러 부분에 산재되어 있어 방사선측정기의 측정값이 상대적으로 낮게 측정된 결과로 생각 된다. 실질적으로 방사성 오염도를 측정한 결과 반출기준과 자체처분 기준을 상당량 초과하는 방사능이 존재하는 것을 확인할 수 있었다. 환의와 시트의 최소보관기간 산출에는 핵종 농도를 기준으로 하는 자체처분 기준을 적용하는 것이 더 적합하다고 할 수 있다. 방사능에 오염된 환의 및 시트는 최소 60일 정도는 보관해야 성급한 재사용에 따른 불필요한 방사선피폭 및 오염 확산을 방지할 수 있을 것으로 생각된다.

  • PDF