• Title/Summary/Keyword: Paper based microfluidics

Search Result 15, Processing Time 0.018 seconds

Characterization of Microfluidic Channels using DVD Pick-up Fluorescent Scanner (광 픽업 방식 형광스캐너를 이용한 미소유체 특성 분석)

  • Yim, Vit;Kim, Jae-Hyun;Lee, Seung-Yop;Park, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1102-1106
    • /
    • 2008
  • Microfluidics deals with the behavior, precise control and manipulation of fluids at a micro scale. It has become increasingly prevalent in various applications such as biomedical applications (diagnostics, therapeutics, and cell/tissue engineering), inkjet head, and fuel cells etc. The issue of inspection and characterization of microfluidics has emerged as a major consideration in design, fabrication, and detection of microfluidic devices. In this paper, we characterize a diffusion based mixing in Y-microchannel using a fluorescent optical scanner based on a DVD pick-up module, which is widely used in optical storages. Using fluorescent dye, we measure the fluorescent intensity that represents the mixing patterns in Y-microchannel. We also compare these experimental results with computational fluid dynamics (CFD) simulation ones. It is shown that the proposed optical scanner can be used as an alternative measurement system with high performance and cost-effectiveness, compared to conventional optical tools such as epifluorescent microscopes using high resolution CCD camera and confocal microscopes with photomultiplier (PMT) detectors.

Fabrication of Biochip Using Gray-scale Photolithography (Gray-scale photolithography를 이용한 바이오칩 제작)

  • Bae, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.137-141
    • /
    • 2008
  • Biochip, which implements bioanalytical process on a tiny surface, is one of candidates for medical diagnosis, drug screening, and molecular sensing. In general, a type of biochip based on microfluidics is composed of microcomponents including microchannel, pump, and valve, which require complicated processes. In this study, gray-scale photolithography(GSPL) was applied to fabricate a biochip with multiple layers. A mould for casting PDMS(polydimethylsiloxane) channel, was fabricated using GSPL. A gray-photomask was prepared by printing gray patterns on a high-quality glossy paper followed by photoreducing by 10:1 onto the photo-film. The formation of multiple layers was studied according to the change of gray level of pattern and the developing time. A biochip composed of a weir(multiple layer structure) and a reaction chamber in a single microchannel was fabricated in a glass plate. Finally, we investigated the application of biochip to antigen-antibody reaction by packing the microbead coated with antibody.

Design and fabrication of paper microfluidic channel (종이기반 미세유체 채널의 설계 및 제작기술)

  • Lee, Jung-Hyun;Hwang, Yoo-Sun;Jung, Hyo-Il
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.525-530
    • /
    • 2011
  • Emotion is composed of various feelings such as pleasure, sorrow, comfortability, and so on. The complicated process of the measurement has long been recognized as a major hindrance for the studies of emotion. Previously, individuals' emotion has mainly been measured by means of self-report, interview, EEG (electroencephalogram), ECG (electrocardiogram), EOG (electroculography), and body temperature. With thanks to nano/micro technologies, the possibility in the development of emotion-on-a-chip (EOC) has begun to be proposed. EOC will make it possible to analyze one's psychological status by taking a drop of blood. Discovery of emotional biomarkers in body fluids, understanding of the correlation between those biomarkers and the results from brain science are prerequisites to validate the EOC technology. In this paper, paper microfluidics are introduced as a good candidate for the EOC. As paper microfluidics is cost-effective and easy to use it is expected to be a useful device for the emotion measurement. We present the design and fabrication process for the simple paper-based microfluidic device and discuss the possible application in the field of measuring the human emotion.

  • PDF

Design of Fluorescence Multi-cancer Diagnostic Sensor Platform based on Microfluidics (미세 유체 기반의 형광 다중 암 진단 센서 플랫폼 설계)

  • Lee, B.K.;Khaliq, A.;Jeong, M.Y.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.55-61
    • /
    • 2022
  • There is a major interest in diagnostic technology for multiple cancers worldwide. In order to reduce the difficulty of cancer diagnosis, a liquid biopsy technology based on a microfluidic device using trace amounts of biofluids such as blood is being studied. And optical biosensing, which measures the concentration of analytes through fluorescence imaging using biofluids, requires various strategies to improve sensitivity, and specialists and equipment are needed to carry out these strategies. This leads to an increase in diagnostic and production costs, and it is necessary to develop a technology to solve this problem. In this paper, we design and propose a fluorescent multi-cancer diagnostic sensing platform structure that implements passive self-separation technology and molecular recognition activation functions by fluid mixing, only with the geometry and microfluidic phenomena of microchannels based on self-driven flow by capillary force. In order to check the parameters affecting the performance of the plasma separation part of the designed sensor, the hydrodynamic diameter of the channel and the viscosity of the fluid were set as variables to confirm the formation of plasma separation flow through simulation. And finally, we propose an optimal sensor platform structure.

Microfluidic immunoassay using superparamagnetic nanoparticles in an enhanced magnetic field gradient (강화된 자기장 구배 하에서 나노자성입자를 이용한 미세유체 기반의 면역 측정)

  • Hahn, Young-Ki;Kang, Joo-H.;Kim, Kyu-Sung;Park, Je-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.158-163
    • /
    • 2006
  • This paper reports a novel immunoassay method using superparamagnetic nanoparticles and an enhanced magnetic field gradient for the detection of protein in a microfluidic device. We use superparamagnetic nanoparticles as a label and fluorescent polystyrene beads as a solid support. Based on this platform, magnetic force-based microfluidic immunoassay is successfully applied to analyze the concentration of IgG as model analytes. In addition, we present ferromagnetic microstructure connected with a permanent magnet to increase magnetic flux density gradient (dB/dx, ${\sim}10^{4}$ T/m), which makes limit of detection reduced. The detection limit is reduced to about 1 pg/mL.

Microfluidic cell sizing using hydrophoretic size-based separation (유체영동 기반의 입자분리현상을 이용한 세포 크기 측정방법)

  • Choi, Sung-Young;Park, Je-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.245-249
    • /
    • 2008
  • This paper presents a microfluidic cell sizing method using hydrophoretic size-based separation. By exploiting slanted obstacles in a microchannel, we can generate a lateral pressure gradient so that microparticles can be deflected and arranged along lateral flows induced by the gradient. Using such movement of particles, we discriminated 8 to 15 μm-sized beads. We measured the size of U937 cells by comparing the hydrophoretic response of the cells to those of the size-standard beads whose diameters are known. Due to its simple design and fabrication, the sizing method can be easily integrated with other microfluidic components such as cell culture chambers conducting on-chip sizing and sorting.

The Effects of pH on Microfluidics Flow Characteristics of Heavy Metals (중금속 오염물의 미세유체 흐름특성에 미치는 pH 영향에 관한 연구)

  • Han, Jung-Geun;Kim, Dong-Chan;Hong, Kikwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.1
    • /
    • pp.23-32
    • /
    • 2015
  • This paper describes a flow experiment and characteristics of heavy metals based on microfluidics, in order to improve the prefabricated vertical drain system that is possible pollutants removal and soil improvement in soft ground polluted with various pollutants, simultaneously. The result showed that the surface with hydrophobic condition affected large effect on flow velocity pollutants, and pH condition was also influence factor for change of flow velocity. Especially, the flow velocity of lead has risen slightly, when pH was close to basicity in complex heavy metal. This means that lead pollutant can reduce a hydrophobic characteristic in comparison with a copper pollutant.

Dynamic Flow Lithography Technologies (역학적 유체 리소그래피 기술)

  • Chung, Su-Eun;Park, Wook;Kwon, Sung-Hoon
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.453-460
    • /
    • 2009
  • In this review paper, concepts in optofluidics are applied to an advanced manufacturing technology based on self-assembled microparts. The "optical" aspect of optofluidics will be described in the context of photolithography, and the "fluidic" aspect will be discussed in the context of self-assembly. First, optofluidic maskless lithography will be introduced as a dynamic fabrication method to generate microparticles in microfluidic channels. Next, the history and application of optofluidic lithography will be presented.

Development of Paper-based Microfluidic Device for Dry Eye Test (종이-미세유체공학을 이용한 건성안 검사 용지 개발)

  • Seo, Young Tae;Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.93-99
    • /
    • 2013
  • Purpose: The aim of this study was to develop a dry eye test method using a paper based microfluidic device that improves inaccuracy caused by using one of current point-of-care dry eye tests such as Shirmer's. Methods: Wax printed hydrophilic chromatography papers were dyed with anthocyanin extracts to detect colorimetric display of liquid samples with varying pH. Fluid distribution rates were measured using artificial tears and human tears directly from 32 subjects. Results: With Shirmer's, fluid distribution rates with small amount of samples (less than $0.5{\mu}l$) were not displayed. However, with paper based microfluidic device, fluid imbibition distances over time were clearly showed. Also clinical results of dry eye from newly developed paper based microfluidic device showed correlation with the results from tear break up time tests. Conclusions: The newly developed paper based microfluidic devices were easy to use and exhibited more accurate clinical results than current dry eye point of care tests such as Shirmer's.