• 제목/요약/키워드: Panel Structure

검색결과 1,283건 처리시간 0.039초

단위 구조 변경에 의한 알루미늄 압출재의 차음성능 개선 (Improvement Method of the Sound Insulation Performance of Aluminium Extruded Panels by the Unit Structure Modification)

  • 이현우;김석현;김정태;송달호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.457-462
    • /
    • 2009
  • In a high speed train, aluminium extruded panel is widely used in floor, side wall and roof structures for high bending stiffness and weight reduction. However, with some inevitable reasons, aluminium extruded panel shows inferior sound insulation performance compared with the flat panel having same weight. Especially, occurrence of local resonance modes in the particular frequency band, is one of the main reason in the deterioration of the sound insulation performance. Local resonance modes are generated in the structure which consists of periodic unit structure, such as the aluminium extruded panel. The local resonance frequency is determined by the specification of the unit structure. In this study, we predict the local resonance frequency band on the aluminium extruded panel used for the high speed train, and investigate how the design modification in the unit structure influences the local resonance frequency band and panel bending stiffness. The purpose of the study is to provide the design information for the effective unit structure in order to improve the sound insulation performance of the aluminium extruded panel.

  • PDF

하니컴 샌드위치 Panel을 이용한 LCD/PDP 생산 공정용 경량 고기능성 복합 신소재 파렛트 제조 및 그 특성 평가 (Fabrication and Its Evaluation of the Light-weight Composite Pallet Plank for an Assembly Line of LCD/PDP by using Honeycomb Sandwich Panel)

  • 김윤해;최병근;손진호;조영대;엄수현;우병훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.304-310
    • /
    • 2006
  • A typical honeycomb sandwich panel consists of two thin, high-strength facings bonded to a thick, light-weight core. Each component by itself is relatively weak and flexible, but when it combined in a sandwich panel they produce a structure that is stiff, strong, and lightweight. To prove the suitability the honeycomb sandwich structure with prepreg, the mechanical properties of the skin materials and honeycomb sandwich structure were evaluated with the static strength tests. Accordingly, the honeycomb sandwich structure made by autoclave process is available for a panel on LCD/PDP assembly line.

선형요소를 사용하여 판넬존 변형을 고려한 해석 모텔 (The Analytical Model Considering the Deformation of Panel Zone with Linear Element)

  • 조소훈;박찬헌;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.293-300
    • /
    • 2004
  • As the structure is taller and its member is larger, the effect of the deformation of Panel zone on the displacement of structure becomes larger. The analysis using the centerline dimensions in the steel moment frame structure can not consider the accurate effect of panel ton And the finite element analysis using infinitesimal solid and shell element is impractical for the total tall building structure. Therefore, this paper proposes the analytical model using linear element in order to be able to evaluate the reasonable deformation of panel zone. the proposed analytical model makes the analysis of the building structure simple and ease because it uses the only linear elements. In addition it can easily incorporate the various parameters affecting the deformation of panel zone. In order to prove the validith of the prosed analytical model, the analysis result using the proposed analytical model is compared with the result using finite element analysis with shell element

  • PDF

소형 경량판넬을 이용한 차음성능 영향요인별 음향감쇠계수 분석 (Characteristics of Sound Reduction Index through Small Sized Lightweight Panel)

  • 양홍석;김명준;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.138-147
    • /
    • 2007
  • Recently, framed structure is increasingly being used as apartment structure due to the advantages during remodeling. Therefore, the use of lightweight panel as separating wall is increasing. To construct lightweight panel structures with sound insulation performance appropriate to the conditions of each field, measurement of sound reduction index(SRI) through panel structures should be performed. In this study, measurement of SRI through 46 kinds of panel structures was performed in the condition of various factors such as surface density, air space and absorber. The result showed that SRI of panel structures was generally higher by increasing of surface density. In the case of double panel with no absorber, SRI at below critical frequency was gradually increased according to rise of air space. Double panel with absorber make remarkable improvement in SRI at low frequency, but there is a little difference compared with SRI of double panel with no absorber over critical frequency.

  • PDF

Nonlinear thermal buckling behaviour of laminated composite panel structure including the stretching effect and higher-order finite element

  • Katariya, Pankaj V.;Panda, Subrata K.;Mahapatra, Trupti R.
    • Advances in materials Research
    • /
    • 제6권4호
    • /
    • pp.349-361
    • /
    • 2017
  • The nonlinear thermal buckling load parameter of the laminated composite panel structure is investigated numerically using the higher-order theory including the stretching effect through the thickness and presented in this research article. The large geometrical distortion of the curved panel structure due to the elevated thermal loading is modeled via Green-Lagrange strain field including all of the higher-order terms to achieve the required generality. The desired solutions are obtained numerically using the finite element steps in conjunction with the direct iterative method. The concurrence of the present nonlinear panel model has been established via adequate comparison study with available published data. Finally, the effect of different influential parameters which affect the nonlinear buckling strength of laminated composite structure are examined through numerous numerical examples and discussed in details.

승용차 대시부의 구조 방사 효율 저감 방법 제안 (A Suggestion of Method to reduce the Radiation Efficiency of Dash Panel of a Passenger Car)

  • 김영기;강연준;안옥균;기지현;최윤봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.268-272
    • /
    • 2002
  • A study to determine the structure-borne noise radiated by a dash panel of a real car is performed by using the finite element method (FEM) and the boundary element method (BEM). The radiation efficiency is used to estimate the structure-borne noise radiated by a dash panel. The curved surfaces of a dash panel change the radiation efficiency. Experimental results of radiation efficiency of a simple rectangular plate and a dash panel show good agreements with the simulation results.

  • PDF

하니컴 샌드위치 Panel을 이용한 LCD/PDP생산공정용 고기능성 복합 신소재 파렛트의 최적설계 (The Optimum Design of the Light-weight Composite Pallet Plank for Assembly Line of LCD/PDP by using Honeycomb Sandwich Panel)

  • 김윤해;최병근;손진호;조영대;엄수현;우병훈
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.388-394
    • /
    • 2005
  • A typical honeycomb sandwich panel consists of two thin, high-strength facings bonded to a thick, light-weight core. Each component by itself is relatively weak and flexible, but when it combind in a sandwich panel they produce a structure that is stiff, strong, and lightweight. In addition to use in honeycomb sandwich panels, honeycomb is used for energy absorption, radio frequency shielding, light diffusion, and to direct air flow.Accordingly, the usage of honeycomb sandwich structure is very widely applied to the aircraft, the automobile, and marine industry, etc., because of these advantages. Generally, this honeycomb sandwich structure is manufactured by autoclave process.In this study, the honeycomb sandwich structure was produced by prepreg. To prove the suitability the honeycomb sandwich structure with prepreg, The optimum design of the skin materials and honeycomb sandwich structure were evaluated with the theory of stress analysis.

  • PDF

패널존과 점성감쇠기를 고려한 강골조 구조물의 내진 설계 모델 (Seismic Design of Steel Frame Model Considering the Panel Zone and Viscous Dampers)

  • 박순응;이택우
    • 한국공간구조학회논문집
    • /
    • 제20권2호
    • /
    • pp.87-94
    • /
    • 2020
  • The present study is aimed to calculate the optimal damping according to the seismic load on the structure with a non-seismic design to perform structure analysis considering the deformation of structural joint connection and panel zone; to develop design program equipped with structural stability of the steel frame structures reinforced with the panel zone and viscous dampers, using the results of the analysis, in order to systematically integrate the seismic reinforcement of the non-seismic structures and the analysis and design of steel frame structures. The study results are as follows: When considering the deformation of the panel zone, the deformation has been reduced up to thickness of the panel double plate below twice the flange thickness, which indicates the effect of the double plate thickness on the panel zone, but the deformation showed uniform convergence when the ration is more than twice. The SMRPF system that was applied to this study determines the damping force and displacement by considering the panel zone to the joint connection and calculating the shear each floor for the seismic load at the same time. The result indicates that the competence of the damper is predictable that can secure seismic performance for the structures with non-seismic design without changing the cross-section of the members.

에폭시 섬유판넬을 이용한 수중구조물의 단면보수시스템에 대한 성능평가 (Performance Evaluation of the Underwater Structure which used a Epoxy Panel)

  • 박준명;홍성남;박선규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.343-346
    • /
    • 2003
  • Confirmation of a damage degree and repair about a damage part are very hard for an underwater structure. And quality control of a construction is very complicated even if repair work is carried out on a damaged structure because repair work is carried out in water. If repair work is carried out while a defect part of the structure which there is in water keeps dry state, a efficient of repair is maximized. However, as for the repair technology about an underwater structure, a systematic researcher is not enough because of the environmental trouble. And, as for the effect about repair method to be applied to a currently underwater structure, it is not certainly proved. In this study The repair work of an underwater structure damaged applied the method that used a fiber panel form work. And a efficient of structure repaired was evaluated.

  • PDF

플라즈마 디스플레이의 개방형 유전체 구조에서 기입방전특성을 향상시키기 위한 Vt 폐곡선 분석 (Vt Close Curve Analysis for Improving Address Discharge Characteristics in Open Dielectric Structure of AC PDP)

  • 조병권
    • 전자공학회논문지
    • /
    • 제51권1호
    • /
    • pp.179-184
    • /
    • 2014
  • 교류형 플라즈마 디스플레이에서의 Vt 폐곡선 측정에 기초하여 개방형 유전체 구조에서 방전 전압과 내부 벽전압 등의 방전 특성이 종래의 구조와 비교되어 조사되었다. 일반적인 교류형 플라즈마 디스플레이의 구조에서 상판은 유리, 전극, 유전체 등으로 이루어져 있는데, 개방형 유전체 구조는 상판 전극사이에 있는 유전체를 제거하여 상판에 있는 유지 전극간의 방전이 더욱 쉽게 발생하도록 하는 구조이다. 개방형 유전체 구조는 종래의 구조와 다르기 때문에 종래의 구동파형으로 구동시에 여러 가지 문제가 발생한다. 특히 상판의 두 전극인 주사와 유지전극 간 방전 개시전압이 달라지기 때문에 종래의 기입 파형을 포함한 초기화 파형도 수정되어야 한다. 본 연구에서는 종래와 개방형 유전체 구조에서 3 전극의 방전개시전압을 비교하기 위하여 Vt 폐곡선을 측정하였고 분석에 기초하여 개방형 유전체 구조에 적합하도록 구동파형이 수정되었다.