Vt Close Curve Analysis for Improving Address Discharge Characteristics in Open Dielectric Structure of AC PDP  

Cho, Byung-Gwon (Department of Image Science and Engineering, Pukyong National University)
Publication Information
Journal of the Institute of Electronics and Information Engineers / v.51, no.1, 2014 , pp. 179-184 More about this Journal
Abstract
The discharge characteristics of an open dielectric structure were investigated, especially such as a firing voltage and related wall voltage, compared with conventional panel structure based on the Vt close curve measurement in AC plasma display panel. While the front panel of the conventional structure in AC plasma display panel was composed of the glass, electrodes, and dielectric, the open dielectric structure could easily produce the discharge between the scan and the sustain electrodes by erasing the dielectric layer between two electrodes. As the open dielectric structure differ from the conventional structure, various problems were produced when driving with the conventional driving waveform. Especially, due to the changes in the discharge firing characteristics of the open dielectric structure between the scan and the sustain electrodes on the front panel, the conventional reset waveform including the address waveform needed to be modified. In this study, the Vt close curves were measured to compare the discharge firing voltages on three electrodes in the conventional and open dielectric structure and based on the Vt close curve analysis, the modified driving waveform suitable for the open dielectric structure was proposed.
Keywords
Open dielectric structure; Wall charge; Vt close curve; Driving waveform; AC PDP;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 D. S. Lee, J. W. Ok, H. J. Lee, H. J. Lee, D. H. Kim and C. H. Park, A study on improvement of luminous efficacy in AC PDP with open dielectric structure, Proc. of IDW 04, pp. 977-980, Niigata, Japan, Dec 2004.
2 H. Hirakawa, T. Katayama, S. Kuroki, T. Kanae, H. Nakahara, T. Nanto, K. Yoshikawa, A. Otsuka, and M. Wakitani, "Cell Structure and Driving Method of a 25-in (64-cm) Diagonal High-Resolution Color ac Plasma Display," Proc. of SID 98, pp. 279-282, Anaheim, USA, May 1998.
3 K. Sakita, K. Takayama, K. Awamoto, and Y. Hashimoto, "High-speed Address Driving Waveform Analysis Using Wall Voltage Transfer Function for Three Terminals and Vt Close Curve in Three-Electrode Surface- Discharge AC-PDPs," Proc. of SID 01, pp. 1022-1025, San Jose, USA, June 2001.
4 B. G. Cho, H. S. Tae, K. Ito, N. S. Jung, and K. S. Lee, "Study on discharge stability of cost-effective driving method based on Vt close curve analysis in AC plasma display panel," IEEE Trans. Electron Devices, Vol. 53, No. 5, pp. 1112-1119, May 2006.   DOI   ScienceOn
5 Y. H. Jung, J. Y. Jeong, "New Gray Scale Implementaion Method for Improving Dynamic False Contours in ac PDPs" J. Institute of Electronics Engineers of Korea, Vol. 41-SD, No. 1, pp. 1-8, Jan. 2004.   과학기술학회마을
6 G. Oversluizen, M. Klein, S. de Zwart, S. van Heusden, and T. Dekker, "Improvement of the discharge efficiency in plasma displays," J. Appl. Phys., Vol. 91, No. 4, pp. 2403-2408, Feb 2002   DOI   ScienceOn
7 B. S. Kim, J. H. Kim, H. D. Park, E. W. Lee, Y. S. Lee, and H. S. Tae, "Reduction of power consumption of counter electrode structure in AC-PDP," Molecular Crystals and Liquid Crystals, Vol. 564, No. 1, pp. 85-93, October 2012.   DOI   ScienceOn
8 H. Y. Jung, T. H. Lee, O. K, and K. W. Whang, Address discharge characteristic of high -luminous-efficacy PDP with SrO protecting layer, Proc. of SID 09, pp. 58-61, San Antonio, USA, May 2009.
9 H. S. Tae, K. D. Cho, S. H. Jang, and K. C. Choi, "Improvement in the luminous efficiency using ramped-square sustain waveform in an AC surface-discharge plasma display panel," IEEE Trans. Electron Devices, Vol. 48, No. 7, pp. 1469-1472 ,July 2001.   DOI   ScienceOn