• 제목/요약/키워드: Paired Comparison

Search Result 551, Processing Time 0.023 seconds

Location of the umbilicus in Korean women and its changes after breast reconstruction with an ipsilateral pedicled rectus abdominis musculocutaneous flap

  • Oh, Sangho;Jeon, Hyojin;Son, Daegu
    • Archives of Plastic Surgery
    • /
    • v.45 no.5
    • /
    • pp.425-431
    • /
    • 2018
  • Background The umbilicus makes an important contribution to the natural appearance of the abdomen. To date, studies on its position in Korean women are lacking, and no standards have been established. The purpose of this study was to investigate the position of umbilicus in Korean women and to review changes in its position after ipsilateral pedicled rectus abdominis musculocutaneous (IP-RAM) flap. Methods This research consisted of two studies. In first study, 100 females who visited the emergency department with gastroenteritis between 2007 and 2011 were included. In second study, 40 women who underwent IP-RAM flap in the same period were included. Using abdominal computed tomography, we measured the distance between xiphoid process and umbilicus, represented by value a, and the distance between umbilicus and symphysis pubis, represented by value b. Thus, the location of the umbilicus was represented by the ratio a/b. The data were analyzed using Pearson correlation test and paired t-test. Results In study 1, the mean value of a/b was 1.07. Pearson correlation test revealed a significant correlation between age and a/b. In study 2, the mean value of a/b was 1.16 in preoperative measurements and 1.01 in postoperative measurements. The paired t-test showed a significant difference between preoperative and postoperative measurements, indicating cephalic migration of the umbilicus after surgery. Conclusions The natural position of the umbilicus showed caudal migration with aging. Additionally, in a comparison of preoperative and postoperative measurements in patients who underwent IP-RAM flap, cephalic migration of the umbilicus was observed after surgery.

20s-30s Men's Cosmetics Purchase Decision Factors (20-30대 남성의 화장품 구매결정요인)

  • Jeon, Hyang-Ran;Jae, Mie-Kyung
    • Korean Journal of Human Ecology
    • /
    • v.18 no.6
    • /
    • pp.1237-1246
    • /
    • 2009
  • This study was designed to identify and compare the consumption value and interest in appearance with regard to the comparison of men's cosmetics purchase decision factors. We conducted a survey among 259 men who have experienced the re-purchase of men's cosmetics. All data was analyzed with the SPSS Windows 17.0 program in terms of frequency, percentage, means, standard deviations, paired-t test, Cronbach $\alpha$, factor analyses, and multiple regression. In summary, three findings emerged from this study. First, men's cosmetics purchase decision factors included two subfactors: product quality factors (price, quality, skin compatibility, fragrance) and image factors (trend, brand image, consciousness of others, diversion). Second, a paired-t test revealed that the consideration toward the image factors of a first time purchase decision was lower than the re-purchase decision factors. However the consideration toward the product quality factors of a first time purchase decision was not different from the re-purchase decision factors. Third, the product quality factors were positively influenced by distinction factors of appearance and functional value. And social value, emotional value, and curiosity value were found to be effective in the image factors at the first time of purchase and re-purchase. Also, the product quality factors of re-purchase decisions were influenced by the satisfaction of the first time purchase. This study will contribute to provide some information for marketers in understanding men's cosmetics purchase decisions and to offer basic data for marketing strategies and product development.

Investigation of the Study Plan and Statistical Method of Functional Cosmetics on Human Skin (기능성 화장품의 인체시험 설계 및 통계적용 방법에 대한 고찰)

  • Seo, Young Kyoung;Koh, Jae Sook;Lee, Won Chul
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.2
    • /
    • pp.105-115
    • /
    • 2013
  • In Korea, the human skin tests to evaluate the anti-wrinkles and whitening effect have been accomplished in accordance with the KFDA guideline. Regarding the data of the visual assessment and machinery evaluation of the results for the human skin test, unpaired t-test have been used in order to compare between the test and the control groups and paired t-test for the comparison of effects for before and after. Descriptive statistics such as frequency analyses was used for the questionnaire evaluation data. In many cases of the European and American clinical test centers, the methodology and the statistical analysis were similar to ours. But, the documentation obtained by repeated application from identical individual has high relation. For this reason, it is desirable to apply RM ANCOVA and RM ANOVA to a visual assessment and machinery evaluation. We suggested that RM ANCOVA and RM ANOVA is the new approach to statistical analysis of human test data of functional cosmetics.

Comparison of self-care and self-efficacy before and after childbirth in Pregnant women with Gestational Diabetes Mellitus (당뇨병을 가진 임부의 자가 간호와 자기효능감에 대한 출산 전후 비교)

  • Hong, Ji-Yeon;Lee, Mi-Joon;Kim, Seong-Shin;Lee, Ja-Yeon
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.10
    • /
    • pp.293-301
    • /
    • 2021
  • The aim of this study was to evaluate the difference of self-care and self-efficacy before and after childbirth in pregnant women with diabetes mellitus. Data were collected from 24 May 2018 to 23 May 2020 for 40 pregnant women over the 24th week of pregnancy. The collected data were analyzed by matched paired t-test using the SPSS 27.0 software program. 27 subjects (67.5%) were under the age of 35, and 13 subjects (32.5%) were over the age of 35. Self-care and self-effectiveness scores were lower in postpartum than in prenatal, which was statistically significant (p< .000). Therefore, it is necessary to develop a nursing intervention program to enhance self-care and self-efficacy after childbirth.

Evaluation of Usefulness of Automatic Exposure Control (AEC) by Comparison Analysis of Entrance Surface Dose (ESD) and Entropy in Clinical Application of Digital Radiography (DR) (디지털 방사선 시스템의 노출 유형에 따른 임상 적용 시 입사표면선량 및 Entropy 비교분석을 통한 자동노출제어장치의 유용성 평가)

  • Choi, Ji-An;Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.276-283
    • /
    • 2019
  • The purpose of this study is to evaluate the usefulness of automatic exposure control (AEC) by analyzing entrance surface dose (ESD) and entropy on using automatic exposure and manual exposure. The experimental method was to measure the dose by placing a semiconductor dosimeter on the Rando Phantom for the Pelvis, Abdomen, Skull, and Chest regions. The DICOM file was simultaneously acquired and then entropy was analyzed by using Matlab. As a result, when using the automatic exposure control, dose of all sites was lower than manual exposure's dose and entropy was high. In addition, paired t-test was performed for each item and p<0.05 was found in each item. In conclusion, the use of automatic exposure control can be a useful method to contribute to the optimization of the exposure dose and the image quality by reducing the amount of unnecessary radiation amount and information loss that can occur in X-ray examination.

Comparison of Golf Putting Performance on Transcranial Direct Current Stimulation (경두개직류자극 유뮤에 따른 골프 퍼팅 수행력 비교 분석)

  • Lee, Jae-Woo;Park, Jun-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.1476-1484
    • /
    • 2021
  • The purpose of this study was to compare the golf performance on transcranial direct current stimulation(tDCS). Ten collegiate golfers were participated. SAMPutt basic unit was used to analyze the kinematic data of putter head. A putting platform and a tDCS were used for putting tasks. It was performed paired t-test to compare between before tDCS and after tDCS. A significant level of .05 using SPSS 24.0. Face at aim and backswing variables of putter head were significantly different during flat putting. Impact spot of putter head was significantly different during 2° of hook slope. However, there were not significantly different others slope angle. It was found that transcranial direct current stimulation had a positive effect on kinematic variables. Based on these results, further research is needed to confirm the effect of transcranial direct current stimulation on body stability during putting task.

A Study on the Walkability Scores in Jeonju City Using Multiple Regression Models (다중 회귀 모델을 이용한 전주시 보행 환경 점수 예측에 관한 연구)

  • Lee, KiChun;Nam, KwangWoo;Lee, ChangWoo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.27 no.4
    • /
    • pp.1-10
    • /
    • 2022
  • Attempts to interpret human perspectives using computer vision have been developed in various fields. In this paper, we propose a method for evaluating the walking environment through semantic segmentation results of images from road images. First, the Kakao Map API was used to collect road images, and four-way images were collected from about 50,000 points in JeonJu. 20% of the collected images build datasets through crowdsourcing-based paired comparisons, and train various regression models using paired comparison data. In order to derive the walkability score of the image data, the ranking score is calculated using the Trueskill algorithm, which is a ranking algorithm, and the walkability and analysis using various regression models are performed using the constructed data. Through this study, it is shown that the walkability of Jeonju can be evaluated and scores can be derived through the correlation between pixel distribution classification information rather than human vision.

An Empirical Study on the Comparison of LSTM and ARIMA Forecasts using Stock Closing Prices

  • Gui Yeol Ryu
    • International journal of advanced smart convergence
    • /
    • v.12 no.1
    • /
    • pp.18-30
    • /
    • 2023
  • We compared empirically the forecast accuracies of the LSTM model, and the ARIMA model. ARIMA model used auto.arima function. Data used in the model is 100 days. We compared with the forecast results for 50 days. We collected the stock closing prices of the top 4 companies by market capitalization in Korea such as "Samsung Electronics", and "LG Energy", "SK Hynix", "Samsung Bio". The collection period is from June 17, 2022, to January 20, 2023. The paired t-test is used to compare the accuracy of forecasts by the two methods because conditions are same. The null hypothesis that the accuracy of the two methods for the four stock closing prices were the same were rejected at the significance level of 5%. Graphs and boxplots confirmed the results of the hypothesis tests. The accuracies of ARIMA are higher than those of LSTM for four cases. For closing stock price of Samsung Electronics, the mean difference of error between ARIMA and LSTM is -370.11, which is 0.618% of the average of the closing stock price. For closing stock price of LG Energy, the mean difference is -4143.298 which is 0.809% of the average of the closing stock price. For closing stock price of SK Hynix, the mean difference is -830.7269 which is 1.00% of the average of the closing stock price. For closing stock price of Samsung Bio, the mean difference is -4143.298 which is 0.809% of the average of the closing stock price. The auto.arima function was used to find the ARIMA model, but other methods are worth considering in future studies. And more efforts are needed to find parameters that provide an optimal model in LSTM.

Comparison of Arterial Oxygen Saturation Measured by Pulse Oximetry at Different Sensor Sites in Neurocritical Patients (신경계 중환자의 측정부위별 맥박 산소포화도의 비교)

  • Jeon, Min-Jeong;Hwang, Sun-Kyung
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • Purpose : This study aimed to compare peripheral pulse oxygen saturation (SpO2) values, measured at different monitoring sites, and arterial oxygen saturation (SaO2) of neurocritical patients. Methods : The study included 110 patients admitted to the neurosurgical intensive care unit of a university hospital. The patients' SpO2 values were measured in their index fingers, both second toes, both earlobes, and foreheads, using the patient monitoring system. These values were compared with the standard value of SaO2 measured using a blood gas analyzer. Data were analyzed using descriptive values, Pearson's correlation coefficients, Lin's concordance correlation coefficients (CCC), and Bland-Altman plots. Result : Regardless of the measuring site, SpO2 was correlated with the paired measurements of SaO2 (r=.40~.60, p<.001, CCC range=.40~.58). No significant bias in paired measurements of SpO2 and SaO2 was observed at all sites (-0.06~0.19%, p>.05). SpO2 values at the left finger and right earlobe had the narrowest range, with a 95% limits of agreement (LOA) (left finger -3.04~2.93% and right earlobe -3.18~2.79%). SpO2 at the index finger, on the side without an arterial catheter, had a narrower range of 95% LOA than that of the opposing finger (-3.00~2.97% vs. -3.73~3.26%). Conclusion : SpO2 at the finger without an arterial catheter had the highest level of precision. This study suggests using the index finger, on the side without an arterial catheter, for pulse oximetry in neurocritical patients.

Prostate Volume Measurement by TRUS Using Heights Obtained by Transaxial and Midsagittal Scanning: Comparison with Specimen Volume Following Radical Prostatectomy

  • Sung Bin Park;Jae Kyun Kim;Sung Hoon Choi;Han Na Noh;Eun Kyung Ji;Kyoung Sik Cho
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.110-113
    • /
    • 2000
  • Objective: The purpose of this study was to determine, when measuring prostate volume by TRUS, whether height is more accurately determined by transaxial or midsagittal scanning. Materials and Methods: Sixteen patients who between March 1995 and March 1998 underwent both preoperative TRUS and radical prostatectomy for prostate cancer were included in this study. Using prolate ellipse volume calculation (height × length × width × 𝜋/6), TRUS prostate volume was determined, and was compared with the measured volume of the specimen. Results: Prostate volume measured by TRUS, regardless of whether height was determined transaxially or midsagittally, correlated closely with real specimen volume. When height was measured in one of these planes, a paired t test revealed no significant difference between TRUS prostate volume and real specimen volume (p = .411 and p = .740, respectively), nor were there significant differences between the findings of transaxial and midsagittal scanning (p = .570). A paired sample test, however, indicated that TRUS prostate volumes determined transaxially showed a higher correlation coefficient (0.833) and a lower standard deviation (9.04) than those determined midsagittally (0.714 and 11.48, respectively). Conclusion: Prostate volume measured by TRUS closely correlates with real prostate volume. Furthermore, we suggest that when measuring prostate volume in this way, height is more accurately determined by transaxial than by midsagittal scanning.

  • PDF