References
- Oddo M, Bosel J. Monitoring of brain and systemic oxygenation in neurocritical care patients. Neurocritical Care. 2014;21(S2):103-20. https://doi.org/10.1007/s12028-014-0024-6
- Miller CM, Torbey MT. Neurocritical care monitoring. New York: DEMOS Medical; 2015.
- Lopez HV, Vivas MF, Ruiz RN, Martinez JR, Navaridas BG-V, Villa MG, et al. Association between post-procedural hyperoxia and poor functional outcome after mechanical thrombectomy for ischemic stroke: an observational study. Annals of Intensive Care. 2019;9(1):1-10. https://doi.org/10.1186/s13613-019-0533-8
- Hoesch RE, Lin E, Young M, Gottesman RF, Altaweel L, Nyquist PA, et al. Acute lung injury in critical neurological illness. Critical Care Medicine. 2012;40(2):587-93. https://doi.org/10.1097/CCM.0b013e3182329617
- Ko SB. General management of acute stroke. Journal of the Korean Medical Association. 2009;52(4):334-9. https://doi.org/10.5124/jkma.2009.52.4.334
- Badenes R, Maruenda A. Advanced monitoring in neurocritical care: brain tissue oxygen pressure. In: Khan Z, editor. Challenging Topics in Neuroanesthesia and Neurocritical Care. New York: Springer; 2017. p. 27-41. https://doi.org/10.1007/978-3-319-41445-4_2
- Byrne AL, Bennett M, Chatterji R, Symons R, Pace NL, Thomas PS. Peripheral venous and arterial blood gas analysis in adults: are they comparable? a systematic review and meta-analysis. Respirology. 2014;19(2):168-75. https://doi.org/10.1111/resp.12225
- Hinkelbein J, Fiedler F, Hose D. Comparison of three different sensor sites for pulse oximetry in critically ill patients. International Journal of Intensive Care. 2005;12(4):159-64.
- Myatt R. Pulse oximetry: what the nurse needs to know. Nursing Standard. 2017;31(31):42-5. https://doi.org/10.7748/ns.2017.e9940
- Wouters PF, Gehring H, Meyfroidt G, Ponz L, Gil-Rodriguez J, Hornberger C, et al. Accuracy of pulse oximeters: the European multi-center trial. Anesthesia and Analgesia. 2002;94(1):13-6.
- Valdez-Lowe C, Ghareeb SA, Artinian NT. Pulse oximetry in adults. American Journal of Nursing. 2009;109(6):52-9. https://doi.org/10.1097/00000446-200906000-00036
- DeMeulenaere S. Pulse oximetry: uses and limitations. The Journal for Nurse Practitioners. 2007;3(5):312-7. https://doi.org/10.1016/j.nurpra.2007.02.021
- Jubran A. Pulse oximetry. Critical Care. 2015;19(1):1-7. https://doi.org/10.1186/s13054-015-0984-8
- Nesseler N, Frenel J-V, Launey Y, Morcet J, Malledant Y, Seguin P. Pulse oximetry and high-dose vasopressors: a comparison between forehead reflectance and finger transmission sensors. Intensive Care Medicine. 2012;38(10):1718-22. https://doi.org/10.1007/s00134-012-2659-0
- Schallom L, Sona C, McSweeney M, Mazuski J. Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion. Heart & Lung. 2007;36(3):188-94. https://doi.org/10.1016/j.hrtlng.2006.07.007
- Hodgson CL, Tuxen DV, Holland AE, Keating JL. Comparison of forehead max-fast pulse oximetry sensor with finger sensor at high positive end-expiratory pressure in adult patients with acute respiratory distress syndrome. Anaesthesia and Intensive Care. 2009;37(6):953-60. https://doi.org/10.1177/0310057x0903700620
- Seifi S, Khatony A, Moradi G, Abdi A, Najafi F. Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes. BMC Nursing. 2018;17(1). https://doi.org/10.1186/s12912-018-0283-1
- Wax DB, Rubin P, Neustein S. A comparison of transmittance and reflectance pulse oximetry during vascular surgery. Anesthesia and Analgesia. 2009;109(6):1847-9. https://doi.org/10.1213/ane.0b013e3181bbc446
- Faul F, Erdfelder E, Lang A-G, Buchner A. G* Power 3: a flexible statistical power analysis program for the social, Behavioral, and Biomedical Sciences. Behavior Research Methods. 2007;39(2):175-91. https://doi.org/10.3758/BF03193146
- Chan ED, Chan MM, Chan MM. Pulse oximetry: understanding its basic principles facilitates appreciation of its limitations. Respiratory Medicine. 2013;107(6):789-99. https://doi.org/10.1016/j.rmed.2013.02.004
- Castro D, Patil SM, Keenaghan M. Arterial Blood Gas [Internet]. Treasure Island, FL: StatPearls Publishing; 2022 [cited 2023 February 22]. Available from: https://www.ncbi.nlm.nih.gov/books/NBK536919/
- Powers WJ, Rabinstein AA, Ackerson T, Adeoye OM, Bambakidis NC, Becker K, et al. 2018 guidelines for the early management of patients with acute ischemic stroke: a guideline for healthcare professionals from the American Heart Association/American Stroke Association. Stroke. 2018;49(3):e49-99. https://doi.org/10.1161/str.0000000000000158
- Badenes R, Bilotta F. Neurocritical care for intracranial haemorrhage: a systematic review of recent studies. British Journal of Anaesthesia. 2015;115:ii68-74. https://doi.org/10.1093/bja/aev379
- Rincon F, Kang J, Maltenfort M, Vibbert M, Urtecho J, Athar MK, et al. Association between hyperoxia and mortality after stroke. Critical Care Medicine. 2014;42(2):387-96. https://doi.org/10.1097/ccm.0b013e3182a27732
- Frei DR, Young PJ. Oxygen therapy in acute resuscitation. Current Opinion in Critical Care. 2018;24(6):506-11. https://doi.org/10.1097/mcc.0000000000000549
- Jo YJ. Latest updates of oxygen therapy. Spring Conference of the Korean Journal of Internal Medicine. 2019:153-6.
- Jeon S-B, Choi HA, Badjatia N, Schmidt JM, Lantigua H, Claassen J, et al. Hyperoxia may be related to delayed cerebral ischemia and poor outcome after subarachnoid haemorrhage. Journal of Neurosurgery & Psychiatry. 2014;85(12):1301-7. https://doi.org/10.1136/jnnp-2013-307314
- European Stroke Organization [ESO] Executive Committee, ESO Writing Committee. Guidelines for management of Ischaemic stroke and transient ischaemic attack 2008. Cerebrovascular Diseases. 2008;25(5):457-507. https://doi.org/10.1159/000131083
- Liao JJ. An improved concordance correlation coefficient. Pharmaceutical Statistics. 2003;2(4):253-61. https://doi.org/10.1002/pst.52
- Singh AK, Sahi MS, Mahawar B, Rajpurohit S. Comparative evaluation of accuracy of pulse oximeters and factors affecting their performance in a tertiary intensive care unit. Journal of Clinical and Diagnostic Research. 2017;11(6):OC05-8. https://doi.org/10.7860/jcdr/2017/24640.9961
- Lee WW, Mayberry K, Crapo R, Jensen RL. The accuracy of pulse oximetry in the emergency department. The American Journal of Emergency Medicine. 2000;18(4):427-31. https://doi.org/10.1053/ajem.2000.7330
- Munoz X, Torres F, Sampol G, Rios J, Marti S, Escrich E. Accuracy and reliability of pulse oximetry at different arterial carbon dioxide pressure levels. European Respiratory Journal. 2008;32(4):1053-9. https://doi.org/10.1183/09031936.00126507
- Haynes JM. The ear as an alternative site for a pulse oximeter finger clip sensor. Respiratory Care. 2007;52(6):727-9.
- Louw A, Cracco C, Cerf C, Harf A, Duvaldestin P, Lemaire F, et al. Accuracy of pulse oximetry in the intensive care unit. Intensive Care Medicine. 2001;27(10):1606-13. https://doi.org/10.1007/s001340101064
- Seguin P, Le Rouzo A, Tanguy M, Guillou YM, Feuillu A, Malledant Y. Evidence for the need of bedside accuracy of pulse oximetry in an intensive care unit. Critical Care Medicine. 2000;28(3):703-6. https://doi.org/10.1097/00003246-200003000-00017
- Han DJ, Bang CH, Kim S, Bae YM, Shin SR, Yang CY, et al. Comparison of peripheral blood flow in post-stroke hemiparetic patients and normal person with doppler ultrasonography. Korean Journal of Oriental Physiology & Pathology. 2009;23(6):1491-6.
- Numaguchi A, Adachi YU, Aoki Y, Ishii Y, Suzuki K, Obata Y, et al. Radial artery cannulation decreases the distal arterial blood flow measured by power doppler ultrasound. Journal of Clinical Monitoring and Computing. 2014;29(5):653-7. https://doi.org/10.1007/s10877-014-9648-5
- Milutinovic D, Repic G, Arandelovic B. Clinical nurses' knowledge level on pulse oximetry: a descriptive multi-centre study. Intensive and Critical Care Nursing. 2016;37:19-26. https://doi.org/10.1016/j.iccn.2016.05.006
- de Armendi AJ, Govindaraj R. Pulse oximetry. Data Interpretation in Anesthesia. 2017:43-6. https://doi.org/10.1007/978-3-319-55862-2_8
- World Health Organization [WHO]. Pulse oximetry training manual [Internet]. Switzerland: World Health Organization; 2011 [cited 2022 November 15]. Available from: https://cdn.who.int/media/docs/default-source/patient-safety/pulse-oximetry/who-ps-pulse-oxymetry-training-manual-en.pdf?sfvrsn=322cb7ae_6.