• Title/Summary/Keyword: PaCO2

Search Result 366, Processing Time 0.024 seconds

Effects on Optical Characteristics of GaN Polarity Controlled by Substrate

  • Kang, Sang-Won;Shim, Hyun-Wook;Lee, Dong-Yul;Han, Sang-Heon;Kim, Dong-Joon;Kim, Je-Won;Oh, Bang-Won;Kryliouk, Olga;Anderson, Timothy J.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.2
    • /
    • pp.79-86
    • /
    • 2006
  • N-polar, Ga-polar, and non-polar GaN was grown by MBE and MOVPE using various substrates and influence of polarity has been investigated. The GaN growth by MOVPE is along cplane (0001), c-plane (0001), and a-plane (11-20) direction on c-plane (0001), a-plane (11-20) and r-plane (1-102) sapphire substrate respectively. The polarity of the film has a strong influence on the morphology and the optical properties of PA-MBE grown As-doped GaN layers. Strong blue emission from As-doped GaN was observed only in the case of N-polarity (000-1) layers, which was attributed to the highest concentration of Ga dangling bonds for this polarity of a GaN surface.

Synthesis of Mannich Base of Benzoxazolin-2-thione and Alkyl Ester of PAS and Their Antimicrobial Activities (Benzoxazolin-2-thione과 PAS의 Alkyl Ester과의 Mannich Base 합성 및 항균력에 관한 연구)

  • 정원근;정상헌;정필근;윤원영;이남복
    • YAKHAK HOEJI
    • /
    • v.18 no.4
    • /
    • pp.243-248
    • /
    • 1974
  • Nine benzoxazolin-2-thione derivatives were sunthesized as the potential antimicrobial substances. These compounds were tested for the antimicrobial activities using Staphylococcus aureus and Escherichia coli by way of tube dilution method. The three compounds of I, II and VII omjoboted the growth of S.aureus at the concentration of 1${\mu}$g/ml, and III,VI,VIII and IX exhibited considerable antimicrobial activities against S. aureus at the concentration of 10.m.u.g/ml. As to the growth of E. Coli, VII VII and VIII inhibited at the concentration of 1${\mu}$g/,l. II,III and IV exhibited considerable antimicrobial activities against E. coli at the concentration of 10${\mu}$g/ml.

  • PDF

The Clinical Effects of Normocapnia and Hypercapnia on Cerebral Oxygen Metabolism in Cardiopulmonary Bypass (체외순환 시 뇌대사에 대한 정상 탄산분압과 고 탄산분압의 임상적 영향에 관한 비교연구)

  • 김성룡;최석철;최국렬;박상섭;최강주;윤영철;전희재;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.35 no.10
    • /
    • pp.712-723
    • /
    • 2002
  • Substantial alterations in cerebral blood flow(CBF) are known to occur during cardiopulmonary bypass(CPB). Many investigators have speculated that these changes may be responsible for both minor and major cerebral damages after CPB. More recently, these changes in CBF have been observed to be intimately related to the arterial carbon dioxide tension(Pa$CO_2$) maintained during CPB. The present study was prospectively designed to investigate the clinical effects of normocapnic and hypercapnic CPB on the cerebral oxygen metabolism in cardiac surgery Material and Method: Thirty-six adult patients scheduled for elective cardiac surgery were randomized to either normocapnic group (Pa$CO_2$35~40 mmHg, n=18) or hypercapnic group(Pa$CO_2$, 45~55 mmHg, n=18) with moderately hypothermic nonpulsatile CPB(nasopharyngeal temperature of 29~3$0^{\circ}C$). In each patient, middle cerebral artery blood flow velocity( $V_{MCA}$), cerebral arteriovenous oxygen content difference (C(a-v) $O_2$), cerebral oxygen extraction(COE), cerebral metabolic rate for oxygen(CMR $O_2$), cerebral oxygen transport( $T_{E}$ $O_2$), $T_{E}$ $O_2$/CMR $O_2$ ratio, cerebral desaturation(internal jugular bulb blood oxygen saturation $\leq$ 50%), and arterial and jugular bulb blood gas were evaluated throughout the operation. Postoperative neuropsychologic complications were assessed in all patients. All variables were compared between the two groups. Result: VMCA(169.13 $\pm$ 8.32 vs 153.11 $\pm$8.98%), TE $O_2$(1,911.17$\pm$250.14 vs 1,757.40$\pm$249.56), $T_{E}$ $O_2$,/CMR $O_2$ ratio(287.38$\pm$28.051 vs 246.77$\pm$25.84), $O_2$ tension in internal jugular bulb (41.66$\pm$9.19 vs 31.50$\pm$6.09 mmHg), and $O_2$saturation in internal jugular bulb(68.97$\pm$10.96 vs 58.12$\pm$12.11%) during CPB were significantly lower in normocapnic group(p=0.03), whereas hypercapnic group had lower C(a-v) $O_2$(3.9$\pm$0.3 vs 4.9$\pm$0.3 mL/dL), COE(0.3$\pm$0.03 vs 0.4$\pm$0.03), CMR $O_2$(5.8 $\pm$0.5 vs 6.8$\pm$0.6), and arterial blood pH(7.36$\pm$0.09 vs 7.46$\pm$0.07, p=0.04) during CPB. Hypercapnic group had lower incidence of cerebral desaturation than normocapnic group(3 vs 9 patients, p=0.03). Duration of the neuropsychologic complication(delirium) were shorter in hypercapnic group than in normocapnic group(36 vs 60 hrs, p=0.009). Conclusion: These findings suggest that hypercapnic CPB may have salutary effects on the cerebral oxygen metabolism and postoperative neurologic outcomes in cardiac surgery.surgery.

Effect of Packaging Materials and Methods on the Storage Quality of Dried Persimmon (포장재 및 포장방법이 저장곶감의 품질에 미치는 영향)

  • Park, Hyung-Woo;Koh, Ha-Young;Park, Moo-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.321-325
    • /
    • 1989
  • Storage quality dried persimmons was evaluated by 5 scale scoring hedonic sensory analysis in various packaging methods and materials. Dried persimmons were deteriorated within 1 months of storage in polyethyene(PE, 0.08mm) and 1.5-2.5 months in nylon(PA/PE, 0.1mm) packages at room temperature, But those were kept good quality for 5 months of storage in PA/PE package and for 8 months in $CO_2$ or $N_2$ gas filled polyester/aluminum/casteded polypropylene(PET/Al./CPP, 0.1mm) package at $5^{\circ}C$. Dried persimmon had the best quality in water content of 37% and at humidity 75% and its shelf-life was noticialy prolonged by low temperature.

  • PDF

The Electrochemical Characteristics of MEA with Pt/Cross-Linked SPEEK-HPA Composite Membranes/Pt-Ru for Water Electrolysis (수전해용 Pt/공유가교 SPEEK-HPA 복합막/Pt-Ru MEA의 전기화학적 특성)

  • Hwang, Yong-Koo;Woo, Je-Young;Lee, Kwang-Mun;Chung, Jang-Hoon;Moon, Sang-Bong;Kang, An-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.3
    • /
    • pp.194-201
    • /
    • 2009
  • The e1ectrocatalytic properties of heteropolyacids(HPAs) entrapped in covalently cross-linked sulfonated polyetheretherketone(CL-SPEEK/HPA) membranes have been studied for water electrolysis. The HPAs, including tungstophosphoric acid(TPA), molybdophosphoric acid(MoPA), and tungstosilicic acid(TSiA) were used as additives in the composite membranes. The MEA was prepared by a non-equilibrium impregnation-reduction(I-R) method, using reducing agent, sodium borohydride(NaBH4) and tetraamineplatinum(II) chloride(pt(NH$_3$)$_4$Cl$_2$). The electrocatalytic properties of composite membranes such as the cell voltage were in the order of magnitude CL-SPEEKlMoPA40 (wt%) > /TPA30 > /TSiA40. In the optimum cell applications for water electrolysis, the cell voltage of PtlPEM/Pt-Ru MEA with CL-SPEEKlTPA30 membrane was 1.75 V at 80$^{\circ}$C and I A/cm$^2$ and this voltage carried lower than that of 1.81 V of Nafion 117. Consequently, in regards of electrochemical and mechanical characteristics and oxidation durability, the newly developed CL-SPEEKITPA30 composite membrane exhibited a better performance than the others, but CLSPEEKlMoPA40 showed the best electrocatalytic activity (1.71 Vat 80$^{\circ}$C and 1 A/cm$^2$) among the composite membranes.

Characteristics of A Diaphragm-Type Fiber Optic Fabry-Perot Interferometric Pressure Sensor Using A Dielectric Film (유전체 박막을 이용한 다이아프램형 광섬유 Fabry-Perot 간섭계 압력센서의 특성)

  • Kim, M.G.;Yoo, Y.W.;Kwon, D.H.;Lee, J.H.;Kim, J.S.;Park, J.H.;Chai, Y.Y.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.147-153
    • /
    • 1998
  • The strain characteristics of a fiber optic Fabry-Perot pressure sensor with high sensitivity using a $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$ (N/O/N) diaphragm is experimentally investigated. A 600 nm thick N/O/N diaphragm was fabricated by silicon anisotropic etching technology in 44 wt% KOH solution. An interferometric fiber optic pressure sensor has been manufactured by using a fiber optic Fabry-Perot intereferometer and a N/O/N diaphragm. The 2 cm length fiber optic Fabry-Perot interferometers in the continuous length of single mode fiber were produced with two pieces of single mode fiber coated with $TiO_{2}$ dielectric film utilizing the fusion splicing technique. The one end of the fiber optic Fabry-Perot interferometer was bonded to a N/O/N diaphragm. and the other end was connected to an optical setup through a 3 dB coupler. For the N/O/N diaphragm sized $2{\times}2\;mm^{2}$ and $8{\times}8\;mm^{2}$, the pressure sensitivity was measured 0.11 rad/kPa and 1.57 rad/kPa, respectively, and both of the nonlinearities were less than 0.2% FS.

  • PDF

The Effects of Artificial Dead Space on the Pulmonary Ventilation of Intubated Children with Mechanical Ventilation (기관 삽관후 인공호흡기를 적용한 개심술 환아의 인공기도 체외 용적이 폐환기 상태에 미치는 영향)

  • 유정숙;윤선희;송계희;민열하
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.1
    • /
    • pp.31-42
    • /
    • 2001
  • This study was done to evaluate the effect reducing artificial dead space on intubated children. Data were collected from July 1st, 1998 to August 31st, 1999. The subjects were selected from a pediatric intensive care unit of 'S' hospital and intubated with 3.5 mm or 4.5 mm endotracheal tube after open heart surgery. They were composed of 34 patients : 17 patients were assigned to the experimental group and the rest of them were placed in the control group. The artificial airway volume was minimized in the experimental group, and the control group maintained the artificial airway volume. ETCO2, PaCO2, SPO2 were measured as indicators of pulmonary ventilation. The tools of this study were GEM-Premier and Space-Lab patient monitors. The data were analyzed using the SPSS/PC+ program. The $\chi$2 -test was used to find general characteristics. The t-test was used to test the homogenety of the pulmonary ventilation status and mechanical ventilation setting before intervention between the two groups. Also, the paired t-test was used to examine the hypothesis. The results can be summerized as : 1. CO2 can be expelled effectively from the body in case artificial dead space was decreased. 2. As the artificial dead space was reduced, the difference between ETCO2 and PaCO2 was decreased, in other words pulmonary ventilation was improved. 3. If the artificial dead space occupied above 15 percent of tidal volume, the effect of CO2 was retention revealed in the body. 4. If the artificial dead space occupied below effect. Based on the results, the following is suggested to be applied practically : 1. A kind of the ventilator circuit acting artificial dead space should be removed from the intubated children with mechanical ventilaion. 2. The endotracheal tube should not be cut because extra-body space of the endotracheal tube did not have an effect on the dead space of the intubated children. Since the researcher could not cover this aspect in the study, they recommend the following. 1. The study should be extended to the other pulmonary disease patients for the effect of improving pulmonary ventilation. 2. Also, further studying with a more narrow interval in the extra-body space of the artificial airway will be able to explain the point of artificial dead space with proper ventilation.

  • PDF

Effects of Modifiers on the Supercritical $CO_{2}$ Extraction of Glycyrrhizin from Licorice and the Morphology of Licorice Tissue after Extraction

  • Kim Hyun Seok;Lee Sang Yun;Kim Byung Yong;Lee Eun Kyu;Ryu Jong Hoon;Lim Gio Bin
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.447-453
    • /
    • 2004
  • Optimal conditions for the supercritical carbon dioxide $(scCO_{2})$ extraction of glycyr­rhizin from licorice (Glycyrrhiza glabra) were investigated, with an emphasis on the types and levels of modifiers. The morphology of the licorice tissue remaining after the $scCO_{2} $ extraction of glycyrrhizin was examined by scanning electron microscopy, coupled with measurements of ab­solute density. Conventional organic solvent extraction was also carried out for purpose of quantitative comparison. At 50 MPa and $60^{circ}C$ glycyrrhizin could not be extracted with pure $scCO_{2}$, while a considerable amount of glycyrrhizin was extracted when water was added to $scCO_{2}$ as a modifier. The highest recovery was found to be about $97\%$ when $70\%$ aqueous methanol was added to $scCO_{2}$ at a concentration of $15\%$. The optimal pressure and temperature for the supercritical fluid extraction of glycyrrhizin were observed to be 30 M Pa and $60^{circ}C$, respectively. Under these conditions, the percentage recovery of glycyrrhizin attained a maximum value of 102.67\pm$ $1.13\%$ within 60 min. Furthermore, in the case of $scCO_{2}$ modified with $70\%$ aqueous methanol, the licorice tissue obtained after extraction was found to be severely de­graded by excessive swelling, and the absolute density of the licorice residues was observed to be the highest.

A Case of Delayed Administration of Naloxone for Morphine Intoxicated Patient (Morphine 과량복용 후 중독증상을 보인 환자의 지연된 Naloxone 치료 1례)

  • Kim, Gun-Bea;Park, Won-Nyung;Gu, Hong-Du
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.10 no.1
    • /
    • pp.33-36
    • /
    • 2012
  • Opioids are the one of the most commonly used drugs to control cancer pain all over the world. But, we should not overlook the potential risk of opioid intoxication because they have well-known detrimental side effects. The opioid intoxication can be diagnosed thorough various clinical manifestations. The altered mental status, respiratory depression, and miosis is very representative clinical features although these symptoms don't always appear together. Unfortunately the opioid-toxidrome can be varied. A 42 years old man came to our emergency room after taking about 900 mg morphine sulfate per oral. He was nearly alert and his respiration was normal. Even though his symptoms didn't deteriorated clinically, serial arterial blood gas analysis showed increase in PaCO2. So we decided to use intravenous naloxone. Soon, he was fully awaked and his pupils size was increased. After a continuous infusion of intravenous naloxone for 2 hours, PaCO2 decreased to normal range and his pupil size also returned to normal after 12 hours. Though the levels of serum amylase and lipase increased slightly, his pancreas was normal according to the abdominal computed tomography. He had nausea, vomit, and whole body itching after naloxone continuous infusion, but conservatively treated. We stopped the continuos infusion after 1 day because his laboratory results and physical examinations showed normal. As this case shows, it is very important to prescribe naloxone initially. If you suspect opioid intoxication, we recommend the initial use of naloxone even though a patient has atypical clinical features. In addition, we suggest intranasal administration of naloxone as safe and effective alternative and it's necessary to consider nalmefene that has a longer duration for opioid intoxication.

  • PDF