• Title/Summary/Keyword: PWM switching method

Search Result 460, Processing Time 0.02 seconds

Adaptive Harmonic Control against DC Input Voltage Fluctuation of PWM Inverter by Instantaneous Integration (순시적분에 의한 PWM인버어터의 직류 입력전압 맥동에 대한 고조파 적응제어)

  • Park, Sung-Jun;Kwon, Y.A.;Kim, Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.721-723
    • /
    • 1993
  • A PWM switching control strategy based on instantaneous integration concept for reducing hamonic components of inverter system with fluctuating input voltage is presented. Applying this strategy to single phase full bridge PWM inverter through bipolor switching method and unipolor switching method, reduction of hamonic components of output voltage and current is demonstrated through simulation. The system operation is examined and confirmed by experiments.

  • PDF

MRSF-PWM Method for Acoustic Noise Reduction of Traction Motor Drive Systems (견인전동기 구동시스템의 소음 저감을 위한 MRSF-PWM 방식)

  • 홍순찬;서영민
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.262-271
    • /
    • 2002
  • In PWM inverters used in traction motor drive systems, the switching frequency is restricted by their large power capacity and thus the electromagnetic acoustic noise is generated. To reduce such an audible noise, the new MRSF-PWM(Modified Random Switching Frequency PWM) method is proposed. In the Proposed MRSF-PWM method, both triangular wave and sawtooth wave are used together as carrier waves for harmonic diffusion and reference wave is generated by injecting 3rd harmonic into the stone wave to expand the linear control region of output voltages. To verify the validity of the proposed MRSF-PWM method, computer simulations are carried out. And the results show that the MRSF-PWM method is more excellent than other RPWM methods in the aspects of both linearity and harmonic diffusion md more effective than SPWM(Sinusoidal PWM) method for the reduction of an audible noise.

PWM Method with Low d-axis Current Ripple for reducing Input Current THD at Light Loads in Three Phase PWM Rectifier (3상 PWM 정류기의 경부하시 입력전류 THD 저감을 위한 d축 전류리플 저감 PWM 방법)

  • Jin, Yong-Sin;Shin, Hee-Keun;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.478-485
    • /
    • 2012
  • In this paper, a new PWM method is proposed to reduce the input current harmonics of 3 phase PWM rectifier. In the conventional carrier comparison PWM method, a triangular wave is generally used as the carrier wave. However, the large d-axis current ripple by the triangle carrier wave may be a source of large input current THD(Total Harmonic Distortion). In this paper, a new carrier comparison PWM method with saw tooth wave is proposed. Depending on the sector where the voltage command vector places, one of the rising or falling saw tooth wave is selected. To reduce the switching losses of the saw tooth carrier PWM, the discontinuous PWM is also presented. The proposed PWM method can reduce the d-axis current ripple as well as the switching losses. The performance of the conventional and proposed PWM methods is verified by the simulation and experimental results.

Study on Hybrid PWM Method under Low Switching Frequency

  • Kekang, Wei;Zheng, Trillion Q.;Wang, Ran;Wang, Chenchen
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.64-69
    • /
    • 2012
  • This paper presents a hybrid pulse width modulation (PWM) method under low switching frequency conditions based on space vector PWM (SVPWM) and selective harmonic eliminated PWM (SHEPWM), which use asynchronous carrier modulation SVPWM at low frequency, and SHEPWM at high frequency, a square wave after rated conditions. A transitive strategy is proposed to realize a smooth transition of individual modes including SVPWM, SHEPWM and square waves. Experimental results confirm this hybrid modulation method and their transition are reasonable and proper.

A PWM Strategy for Noise Reduction of Inverter-Induction Motor Drive System (인버터-유도전동기 구동시스템의 소음 저감을 위한 PWM 방식)

  • Seo, Young-Min;Lee, Ju-Hoon;Yoon, In-Sik;Park, Young-Jeen;Hong, Soon-Chan
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.398-402
    • /
    • 1999
  • In PWM inverter fed traction motor drive systems, the switching frequency is restricted and thus the electromagnetic acoustic noise is generated. To reduce such an audible noise, we propose the modified RSF(Randomized Switching Frequency)-PWM method. In the proposed RSF-PWM method, both triangular wave and sawtooth wave are used in one period as carrier waves. Because the proposed method has inherently the same property as sinusoidal PWM method, there is no problem of linearity. To verify the validity of the modified RSF-PWM method, computer simulations are carried out.

  • PDF

A Switching Method for Minimizing the Over Current in Transient Response of 3-phase Interleaved Bidirectional DC-DC Converter with Frequency Modulation (주파수 변조 방식 3상 인터리브드 양방향 DC-DC 컨버터의 과도상태 과전류를 최소화하기 위한 스위칭 기법)

  • Bae, Jongwoo;Jeong, Hyesoo;Jung, Jae-Hun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.530-537
    • /
    • 2016
  • This work deals with a switching method for minimizing overcurrent in a three-phase interleaved bidirectional DC-DC converter with frequency modulation. Generally, a three-phase interleaved DC-DC converter is used to reduce a current ripple component. The combined operation of three-phase and two-phase converters can significantly reduce the ripple component. However, the conventional PWM method cannot solve severe overcurrent during phase transfer or frequency variation for power control. To overcome this problem, this work proposes a new PWM switching method. A 3 kW DC-DC power converter is designed and implemented, and the converter is operated in discontinuous current mode with varying switching frequencies for power control. Simulation and experimental results show the validity of the proposed switching method. The proposed switching method can be widely used in the field of current ripple reduction for three-phase interleaved bidirectional DC-DC converters.

PWM Method of Voltage Type Converters with Large Modulation Ratio (변조율이 큰 전압형 컨버터의 PWM 변조방법)

  • 이사영;오봉환;김봉희;박현준;김길동;이승학;이미영
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.287-290
    • /
    • 1998
  • This paper presents PWM method which modulates two third period only during one cycle of power converter. This method is compared with the conventionl sinusoidal modulation method applying to the power converter with large capacity necessitating low switching frequency. The presented modulation method enables to reduce power semiconductor rating, minimize switching loss, and improve the current wave form.

  • PDF

A Study on the D-Q Control based Output Voltage Control Algorithm and EMTP-RV Simulation of Three-phase 6-Pulse PWM Rectifier (3상 6펄스 PWM 정류기의 D-Q 제어 기반 출력전압 제어 알고리즘 및 EMTP-RV 시뮬레이션 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.45-52
    • /
    • 2021
  • The space vector control based voltage control method for a three-phase PWM rectifier requires a lot of effort to design an optimal switching pattern since a switching pattern for the switching section must be designed. In this study, a D-Q control based SPWM output voltage control algorithm was studied for the three-phase six-pulse CVS type rectifier. In the output voltage control algorithm, three-phase reference signals are obtained from the D-Q transformation based on the space vector representation method, instead of the switching pattern, SPWM method is used to generate rectifier switching control signals. Next, a three-phase six-pulse CVS PWM rectifier based on D-Q transformation and SPWM was modeled using EMTP-RV. Finally, the validity of the D-Q control-based SPWM voltage control algorithm was confirmed by comparing the output voltage waveform obtained through EMTP-RV simulation works with a reference value and confirming that the output voltage accurately follows the reference voltage.

A Switching Method of Single Phase Grid Connected Inverter for Common Mode Noise Reduction (계통연계형 단상인버터의 Common Mode Noise 저감을 위한 Switching 방법)

  • Lee, Seung-Ju;Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.1
    • /
    • pp.27-33
    • /
    • 2016
  • A pulse-width modulation (PWM) method for common mode noise reduction in a PWM inverter connected to a single-phase grid is proposed in this study. The extensively used conventional switching method may experience common mode voltage problems, which generate current leakage and electromagnetic induction problems. In the proposed switching method, the neutral point of the output voltage is always fixed at both ends of the input voltage to reduce common mode noise. The validity of the proposed method is proven through simulation and experimental results.

Optimized PWM Switching Strategy for an Induction Motor Voltage Control

  • Lee, Hae-Hyung;Hwang, Seuk-Yung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.527-533
    • /
    • 1998
  • An optimized PWM switching strategy for an induction motor voltage control is developed and demonstrated. Space vector modulation in voltage source inverter offers improved DC-bus utilization and reduced commutation losses, and has been therefor recognizedas the perfered PWM method, especially in the case of digital implementation. Three-phase invertor voltage control by space vector modulation consists of switching between the two active and one zero voltage vector by using the proposed optimal PWM algorithm. The prefered switching sequence is defined as a function of the modulation index and period of a carrier wave. The sequence is selected by suing the inverter switching losses and the current ripple as the criteria. For low and medium power application, the experimental results indicate that good dynamic response and reduced harmonic distortion can be achieved by increasing switching frequency.

  • PDF